Function |
XN300 power supply modules |
Connection technique |
Push-in spring-cage terminal |
Function |
24 VDC system power supply for generating the XN300 system power, 4 x 24 VDC / 2 A, short-circuit proof |
Short Description |
Used to distribute system power to XN300 modules; 9 short-circuit proof outputs (24 VDC / GND) in 4 groups (max. 2 A load per output) |
For use with |
XN-312-… |
Standards |
|
Approvals >Approvals |
IEC/EN 61131-2 IEC/EN 61000-6-2 IEC/EN 61000-6-4 |
Approvals >shipping classification |
CE, cULus EAC |
Approvals |
DNV GL |
Electromagnetic compatibility (EMC) >ESD [Air/contact discharge] |
|
Electromagnetic compatibility (EMC) >Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ] |
8 / 4 kV |
Electromagnetic compatibility (EMC) >Burst >Supply cable |
10 / 3 / 1 V/m |
Electromagnetic compatibility (EMC) >Burst >Signal cable |
2 kV |
Electromagnetic compatibility (EMC) >Surge >Supply cable (balanced / unbalanced) |
1 kV |
Electromagnetic compatibility (EMC) >Surge >Signal cable (unbalanced) |
0,5 / 0,5 kV |
Electromagnetic compatibility (EMC) >Radiated RFI |
1 kV |
Electromagnetic compatibility (EMC) >Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)] |
10 V |
Electromagnetic compatibility (EMC) >Voltage fluctuations/voltage dips |
40 / 47 class A dB |
Ambient conditions >Climatic conditions >Climatic proofing |
Yes / 10 ms |
Ambient conditions >Climatic conditions >Air pressure (operation) |
Dry heat to IEC 60068-2-2 Damp heat as per EN 60068-2-3 |
Ambient conditions >Climatic conditions >Relative humidity |
795 - 1080 hPa |
Ambient conditions >Climatic conditions >Condensation |
0 - 95%, non condensing |
Ambient conditions >Temperature >Operation |
prevent with suitable measures |
Ambient conditions >Temperature >Storage, transport [ϑ] |
0 - +60 °C |
Degree of Protection |
-20 - +85 °C |
Mounting position |
IP20 |
Free fall, packaged (IEC/EN 60068-2-32) |
Horizontal |
Vibrations [3,5 mm / 1 g] |
1 m |
Mechanical shock resistance [Semisinusoidal 15 g/11 ms] |
5 - 8.4 / 8.4 -150 Hz |
Rated operational data >Insulating material group |
18 Impacts |
Rated operational data >Overvoltage category / pollution degree |
|
Rated operational data >Rated operating voltage |
I |
Rated operational data >Maximum load current/cross-sectional area |
III / 3 |
Connection design in TOP direction |
160 V |
Gauge pin IEC/EN 60947-1 |
X (not specified by plug manufacturer) A / mm² |
Connection specifications >"e" solid H07V-U |
Push-in spring-cage terminal (plug-in connection) |
Connection specifications >"f" flexible H 07V-K |
A1 |
Connection specifications >"f" with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
0.2 - 1.5 mm2 |
Connection specifications >"f" with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
0.2 - 1.5 mm2
|
Connection specifications >Cable size |
0.25 - 1.5 mm2 |
Power supply - Input >Power supply >Rated operating voltage [Ue] |
0.25 - 1.5 mm2 |
Power supply - Output >Sensor/transmitter supply >Rated operating voltage [Ua] |
24 - 16 AWG |
Power supply - Output >Sensor/transmitter supply >Rated operational current [Imax] |
|
Power supply - Output >Sensor/transmitter supply >Notes on power supply |
24 (X5) V |
Rated operational current for specified heat dissipation [In] |
24 (X1, X2, X3, X4, X5, 9 x output) V |
Heat dissipation per pole, current-dependent [Pvid] |
2 A |
Equipment heat dissipation, current-dependent [Pvid] |
9 outputs in 4 power supply groups, max. total current of 6 A |
Static heat dissipation, non-current-dependent [Pvs] |
|
Heat dissipation capacity [Pdiss] |
0 A |
Operating ambient temperature min. |
0 W |
Operating ambient temperature max. |
0 W |
Degree of Protection |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
+55 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
IP20 |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
|
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Supply voltage AC 50 Hz |
Is the panel builder´s responsibility. |
Supply voltage AC 60 Hz |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Supply voltage DC |
Is the panel builder´s responsibility. |
Voltage type of supply voltage |
Is the panel builder´s responsibility. |
Number of HW-interfaces industrial Ethernet |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of interfaces PROFINET |
|
Number of HW-interfaces RS-232 |
|
Number of HW-interfaces RS-422 |
0 - 0 V |
Number of HW-interfaces RS-485 |
0 - 0 V |
Number of HW-interfaces serial TTY |
18 - 30 V |
Number of HW-interfaces parallel |
DC |
Number of HW-interfaces Wireless |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces other |
0 |
With optical interface |
0 |
Supporting protocol for TCP/IP |
0 |
Supporting protocol for PROFIBUS |
0 |
Supporting protocol for CAN |
0 |
Supporting protocol for INTERBUS |
0 |
Supporting protocol for ASI |
0 |
Supporting protocol for KNX |
0 |
Supporting protocol for MODBUS |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for LON |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for SERCOS |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for INTERBUS-Safety |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supporting protocol for other bus systems |
No |
Radio standard Bluetooth |
No |
Radio standard WLAN 802.11 |
No |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
System accessory |
No |
Degree of protection (IP) |
Yes |
Type of electric connection |
No |
With potential separation |
No |
With power supply module |
No |
Suitable as segment module |
No |
Remote module |
No |
Fieldbus connection over separate bus coupler possible |
Yes |
Bus diagnosis possible |
IP20 |
Rail mounting possible |
Screw-/spring clamp connection |
Wall mounting/direct mounting |
No |
Front build in possible |
No |
Rack-assembly possible |
No |
Suitable for safety functions |
No |
Category according to EN 954-1 |
Yes |
SIL according to IEC 61508 |
No |
Performance level acc. EN ISO 13849-1 |
Yes |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Explosion safety category for gas |
No |
Explosion safety category for dust |
No |
Width |
|
Height |
None |
Depth |
None |
Product Standards |
No |
UL File No. |
No |