alt
alt

EC4P-222-MTXX1
106400 EC4P-222-MTXX1
106400

Kompakt PLC, 24 V DC, 12DI(4AI'nin), 8DO(T), Ethernet, CAN Küçük ve orta ölçekli otomasyon görevleri için kompakt kontrolör, IEC 61131'e (CoDeSys) göre programlama, Ethernet arayüzü ve seri arayüz (ec4p-222 tipleri) programlama, UDP ve Modbus aracılığıyla iletişim ve bağlantı amaçlıdır OPC istemcilerinin

Kompakt PLC, 24 V DC, 12DI(4AI'nin), 8DO(T), Ethernet, CAN
Küçük ve orta ölçekli otomasyon görevleri için kompakt kontrolör, IEC 61131'e (CoDeSys) göre programlama, Ethernet arayüzü ve seri arayüz (ec4p-222 tipleri) programlama, UDP ve Modbus aracılığıyla iletişim ve bağlantı amaçlıdır OPC istemcilerinin

Description Expandable: Inputs/outputs and bus systems
individual laser inscription possible with EC4-COMBINATION-*
Digital easyNet/CANopen® and Ethernet on board
of which can be used as analog
Transistor 12
Supply voltage 4
Dimensions (W x H x D)
Weight 8
Mounting 24 V DC
Solid
Flexible with ferrule 107.5 x 90 x 72 without/79 with adapter for MCC (6 SU) mm
Standard screwdriver 0.3 kg
Max. tightening torque Top-hat rail IEC/EN 60715, 35 mm or screw fixing using 3 fixing brackets ZB4-101-GF1 (accessories)
Operating ambient temperature
Condensation 0.2/4 (AWG 22 - 12) mm2
LCD display (clearly legible) 0.2/2.5 (AWG 22 - 12) mm2
Storage [ϑ] 0.8 x 3.5 mm
Relative humidity, non-condensing (IEC/EN 60068-2-30) 0.6 Nm
Air pressure (operation)
Protection type (IEC/EN 60529, EN50178, VBG 4) -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
Vibrations (IEC/EN 60068-2-6)
>Constant amplitude 0.15 mm
Take appropriate measures to prevent condensation
Vibrations (IEC/EN 60068-2-6)
>Constant acceleration 2 g
0 - 55 °C
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms -40 - +70 °C
Drop to IEC/EN 60068-2-31 [Drop height] 5 - 95 %
Free fall, packaged (IEC/EN 60068-2-32) 1080 - 1080 hPa
Mounting position
Overvoltage category/pollution degree IP20
Electrostatic discharge (ESD)
>applied standard
10 - 57 Hz
Electrostatic discharge (ESD)
>Air discharge
57 - 150 Hz
Electrostatic discharge (ESD)
>Contact discharge
18 Impacts
Electromagnetic fields (RFI) to IEC EN 61000-4-3 50 mm
Radio interference suppression 1 m
Burst Vertical or horizontal
Burst
>Supply cable
Burst
>Signal lines
II/2
power pulses (Surge) IEC EN 61000-4-2, Level 3
Immunity to line-conducted interference to (IEC/EN 61000-4-6) 8 kV
Clearance in air and creepage distances 6 kV
Insulation resistance 10 V/m
Back-up of real-time clock EN 55011 Class B, EN 55022 Class B
Accuracy of the real-time clock IEC/EN 61000-4-4, level 3 kV
Write cycles of the retentive memory 2 kV
Rated operational voltage [Ue] 2 kV
Permissible range [Ue] 2 kV (supply cables, symmetrical, EASY...AC)
0.5 kV (supply cables, symmetrical, easy-DC)
according to IEC/EN 61000-4-5
Residual ripple 10 V
Input current
Voltage dips EN 50178, UL 508, CSA C22.2, No. 142
Heat dissipation [P] EN 50178
Processor
Memory
>Program code/data
252U067
Memory
>Marker/retentive data
① Backup time (hours) with fully charged double layer capacitor
② Service life (years)
Cycle time for 1 k of instructions (Bit, Byte) part no. ± 5 (± 0.5 h⁄Year) s/day
PRG interface RS232
>Data transfer rate
PRG interface RS232
>Connection types
10000000000 (10¹⁰) (Read-write cycles)
PRG interface RS232
>Potential isolation
PRG interface RS232
>Master mode
>Data transfer rate
24 DC (-15/+20%) V
PRG interface RS232
>Master mode
>Character formats
20.4 - 28.8 V DC
PRG interface RS232
>Master mode
>Number of transmission bytes in a block
≦ 5 %
PRG interface RS232
>Master mode
>Number of received bytes in a block
normally 140 mA at Ue
Ethernet
>Data transfer rate
≤ 10
(IEC/EN 61131-2) ms
Ethernet
>Connection types
Normally 3.4 W
Ethernet
>Potential isolation
CANopen®
>Data transfer rate
Infineon XC161
CANopen®
>Bus termination (first and last station)
256/14 segments of 16 KB each kByte
CANopen®
>Connection types
16/4/4/8 KByte
Master mode
>Number
< 0.3 ms
Mode slave
>Stations
Mode slave
>PDO type
4.8, 9.6, 19.2, 38.4, 57.6, 115.2 (character format: 8 bit data, no parity, 1 stop bit) kBit/s
Mode slave
>Control contact rated current
RJ45-bus
Number none
Inputs can be used as analog inputs 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6 kbit/s
Status Display 8E1, 8O1, 8N1, 8N2, 7E2, 7O2, 7N2, 7E1
Potential isolation 190 bytes
Rated operational voltage [Ue] 190 bytes
Input voltage 10 MBit/s, 100 m Mbit/s
Input current on 1 signal
>Input current at signal 1
RJ45
Deceleration time No
Cable length 500 kBit/s, 25 m 250 kBit/s, 60m 125 kBit/s, 125 m 50 kBit/s, 300 m 20 kBit/s, 700 m 10 kBit/s, 1000 m
Incremental counter
>Number of counter inputs
EASY-NT-R plug (incl. bus terminating resistor 120 Ω)
Incremental counter
>Value range
2 x RJ45, 8 pole
Incremental counter
>Counter frequency
8
Incremental counter
>Pulse shape
max. 126 Number
Incremental counter
>Counter inputs
Asynchronous, cyclic, acyclic
Incremental counter
>Reference input
To DS 301 V4
Incremental counter
>Input for reference switch
Incremental counter
>Counter inputs I1 and I2, I3 and I4
12
Incremental counter
>Signal offset
4 (I7, I8, I11, I12)
Rapid counter inputs
>Number
LCD-Display
Rapid counter inputs
>Value range
from the outputs: yes
to network easyNet, easyLink
Rapid counter inputs
>Cable length
24 V DC
Rapid counter inputs
>Counter frequency
< 5 (I1 - I6, I9 - I10) < 8 (I7, I8, I11, I12) at signal "0"
> 15.0 (I1 - I6, I9, I10) > 8.0 (I7, I8, I11, I12) at signal "1" V DC
Rapid counter inputs
>Pulse shape
3.3 (I1 to I6)
2.2 (I7, I8)
3.3 (I9, I10)
2.2 (I11, I12) mA
Number normally 0.02 (I1 - I4), normally 0.25 (I5 - I12) (from ´´0´´ to "1")
normally 0.02 (I1 - I4), normally 0.25 (I5 - I12) (from ´´0´´ to "1") ms
Potential isolation 100 (unshielded) m
Input type 1 (I1, I2, I3, I4)
Signal range 32 Bit
Resolution ≦ 40 kHz
Input impedance Square
Accuracy of actual value
>Within a single device
I1, I2
Conversion time, analog/digital I3
Input current I4
Cable length 1
Number 90°
Rated operational voltage [Ue] 2 (I1, I2) at 16 Bit or 1 (I1) at 32 Bit
Permissible range [Ue] 16/32 Bit
Residual ripple ≦ 20 (screened) m
Supply current ≦ 50 kHz
Protection against polarity reversal Square
Potential isolation
Rated operational current at signal „1” DC per channel [Ie] 4 (I7, I8, I11, I12)
Lamp load without Rv per channel from the outputs: yes
to interface/memory card: no
Residual current on 0 signal per channel DC voltage
Max. output voltage 0-10 V DC
Short-circuit protection 0.01 V analog
0.01 V digital
10 Bit (value 0 - 1023)
Short-circuit tripping current for Ra ≦ 10 mΩ 11.2 kΩ
Total short-circuit current ± 2, (I7, I8, I11, I12) ± 0.12 V %
Peak short-circuit current each CPU cycle ms
Thermal cutout < 1 mA
Max. operating frequency with constant resistive load ≦ 30, screened m
Parallel connection of outputs
>With resistive load, inductive load with external suppressor circuit, combination within a group
Parallel connection of outputs
>Number of outputs [max.]
8
Parallel connection of outputs
>Max. total current
24 V DC
Output status indication 20.4 - 28.8 V DC
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 1 ms, R = 48 Ω, L = 16 mH
>Utilization factor
5 %
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 1 ms, R = 48 Ω, L = 16 mH
>Duty factor
Norm./max. 18/32 at signal 0
24/44 at signal 1 mA
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 1 ms, R = 48 Ω, L = 16 mH
>Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Utilization factor
from power supply, inputs
to the memory card: yes
From the inputs: yes
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Duty factor
Max. 0.5 A
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
5 W
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Utilization factor
< 0.1 mA
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Duty factor
2.5 (signal 0 at external load < 10 MΩ)
U = Ue - 1 V (signal 1 at Ie = 0.5 A) V
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
Yes, electronic (Q1 - Q4), thermal (Q5 - Q8), (analysis via diagnostics input I16, I15)
Inductive load to EN 60947-5-1
>With external suppressor circuit
>Utilization factor
0.7 ≦ Ie ≦ 2 per output A
Inductive load to EN 60947-5-1
>With external suppressor circuit
>Duty factor
16 A
Inductive load to EN 60947-5-1
>With external suppressor circuit
>Max. switching frequency, max. duty factor
32 A
Protection against polarity reversal Yes
Potential isolation 40000 Operations/h
Bus termination (first and last station) Group 1: Q1 - Q4
Group 2: Q5 - Q8
Rated operational current for specified heat dissipation [In] 4
Heat dissipation per pole, current-dependent [Pvid] 2 (Caution! Outputs must be actuated simultaneously and for the same length of time.) A
Equipment heat dissipation, current-dependent [Pvid] LCD-display
Static heat dissipation, non-current-dependent [Pvs] 0.25 g
Heat dissipation capacity [Pdiss] 100 % DF
Operating ambient temperature min. 1500 Operations
Operating ambient temperature max. 0.25 g
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
100 % DF
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
1500 Operations
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0.25 g
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
100 % DF
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
1500 Operations
10.2 Strength of materials and parts
>10.2.5 Lifting
1 g
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
100 % DF
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Depending on the suppressor circuit Operations
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
10.5 Protection against electric shock Yes
10.6 Incorporation of switching devices and components
10.7 Internal electrical circuits and connections EASY-NT-R plug (incl. bus terminating resistor 120 Ω)
10.8 Connections for external conductors
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
0 A
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
0 W
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
0 W
10.10 Temperature rise 3.4 W
10.11 Short-circuit rating 0 W
10.12 Electromagnetic compatibility -25 °C
10.13 Mechanical function +55 °C
Contains function building blocks
Contains basic device Meets the product standard´s requirements.
Contains module rack Meets the product standard´s requirements.
Contains power supply Meets the product standard´s requirements.
Contains analogue input module Meets the product standard´s requirements.
Contains analogue output module Meets the product standard´s requirements.
Contains digital input module Does not apply, since the entire switchgear needs to be evaluated.
Contains digital output module Does not apply, since the entire switchgear needs to be evaluated.
Contains function module Meets the product standard´s requirements.
Contains technology module Meets the product standard´s requirements.
Contains communication module Meets the product standard´s requirements.
Contains memory unit Does not apply, since the entire switchgear needs to be evaluated.
Contains simulation module Does not apply, since the entire switchgear needs to be evaluated.
Contains connection cable Is the panel builder´s responsibility.
Contains control unit Is the panel builder´s responsibility.
Contains monitor Is the panel builder´s responsibility.
Contains programming software Is the panel builder´s responsibility.
Contains engineering software Is the panel builder´s responsibility.
Contains visualization The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Contains libraries Is the panel builder´s responsibility.
Contains documentation Is the panel builder´s responsibility.
Contains other components The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Software preinstalled
Product Standards
UL File No. Yes
UL Category Control No. Yes
CSA File No. No
CSA Class No. Yes
North America Certification Yes
Specially designed for North America No
Current Limiting Circuit-Breaker Yes
Degree of Protection Yes

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

EC4P-221-MTXD1
Eaton
EC4P-221-MTXX1
Eaton
EC4P-221-MRXD1
Eaton
EC4P-221-MRXX1
Eaton
EC4P-221-MTAD1
Eaton
EC4P-221-MTAX1
Eaton
EC4P-221-MRAD1
Eaton
EC4P-221-MRAX1
Eaton
EC4P-222-MTXD1
Eaton
EC4P-222-MTXX1
Eaton
EC4P-222-MRXD1
Eaton