Product range |
Control relays easyE4 |
Subrange |
easyE4 digital input/output enhancements |
Basic function |
easyE4 extensions |
Description |
Input/output extension for easyE4 control relay Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225) Rated operating voltage 12V DC, 24V DC or 24V AC Digital inputs: 4 Digital outputs: 4 relays Screw terminals |
Inputs expansion (number) |
|
Display |
digital: 4 |
Software |
|
Supply voltage |
with diagnostic LED |
For use with |
EASYSOFT-SWLIC/easySoft 7 |
Standards |
12/24 V DC 24 V AC |
Approvals >Approvals |
easyE4 |
Approvals >certificate |
|
Approvals >shipping classification |
EN 61000-6-2 EN 61000-6-3 IEC 60068-2-6 IEC 60068-2-27 IEC 60068-2-30 IEC 61131-2 EN 61010 EN 50178 |
Approvals |
cULus |
Dimensions (W x H x D) |
CE |
Weight |
DNV GL |
Mounting |
|
Connection type |
35.5 x 90 x 58 mm |
Screw terminals >Solid |
0.125 kg |
Screw terminals >flexible |
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Screw terminals >Solid or flexible conductor, with ferrule |
Push-in terminals |
Screw terminals >Solid or stranded |
|
Screw terminals >Standard screwdriver |
0.2 - 4 mm2 |
Screw terminals >Tightening torque |
0.2 - 2.5 mm2
|
Screw terminals >Stripping length |
0,2 - 2,5 mm2
|
Operating ambient temperature |
22 - 12 AWG |
Condensation |
0.8 x 3.5 mm |
Storage [ϑ] |
0.5 - 0.7 Nm |
relative humidity |
6.5 mm |
Air pressure (operation) |
|
Protection type (IEC/EN 60529, EN50178, VBG 4) |
-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Vibrations |
Take appropriate measures to prevent condensation |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms |
-40 - +70 °C |
Drop to IEC/EN 60068-2-31 [Drop height] |
in accordance with IEC 60068-2-30, IEC 60068-2-78 5 - 95 % |
Free fall, packaged (IEC/EN 60068-2-32) |
795 - 1080 hPa |
Mounting position |
|
Overvoltage category/pollution degree |
IP20 |
Electrostatic discharge (ESD) >applied standard |
In accordance with IEC 60068-2-6 constant amplitude 0.15 mm: 10 - 57 constant acceleration 2 g: 57 - 150 Hz |
Electrostatic discharge (ESD) >Air discharge |
18 Impacts |
Electrostatic discharge (ESD) >Contact discharge |
50 mm |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 |
0.3 m |
Radio interference suppression |
Vertical or horizontal |
Burst |
|
power pulses (Surge) |
III/2 |
Immunity to line-conducted interference to (IEC/EN 61000-4-6) |
according to IEC EN 61000-4-2 |
Clearance in air and creepage distances |
8 kV |
Insulation resistance |
6 kV |
Rated operational voltage [Ue] |
0.8 - 1.0 GHz: 10 1.4 - 2 GHz: 3 2.0 - 2.7 GHz: 1 V/m |
Permissible range [Ue] |
EN 61000-6-3 Class B |
Residual ripple |
according to IEC/EN 61000-4-4 Supply cables: 2 Signal cables: 2 kV |
Protection against polarity reversal |
according to IEC/EN 61000-4-5 1 kV (supply cables, symmetrical) 2 kV (supply cables, asymmetrical) |
Frequency |
10 V |
Input current |
|
Voltage dips |
nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Fuse |
in accordance with EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Power loss [P] |
|
Heat dissipation at 24 V DC |
12/24 DC (-15/+20%) 24 AC (-15/+10%) V |
Number |
10.2 - 28.8 V DC 20.4 - 26.4 V AC |
Potential isolation |
≦ 5 % |
Rated operational voltage [Ue] |
yes |
Input voltage |
50/60 (± 5%) Hz |
Input current at signal 1 |
max. 150 mA at 12 V DC max. 80 mA at 24 V DC |
Deceleration time |
≤ 20 ms at 24 V AC 10 ms at 24 V DC 1 ms at 12 V DC ms |
Cable length |
≧ 1A (T) A |
Number |
Normally 2 W |
Potential isolation |
2 W |
Rated operational voltage [Ue] |
|
Input voltage |
4 |
Input current at signal 1 |
from power supply: no between inputs: no from the outputs: yes to base unit: yes to expansion devices: yes |
Deceleration time |
12 V DC |
Cable length |
Status 0: ≦ 5 (I1 - I4) Condition 1: ≧ 8 (I1 - I4) V DC |
Number |
1.75 mA (I1 - I4) mA |
Potential isolation |
type 0.2 (0 -> 1) type 0.15 (1 -> 0) ms |
Rated operational voltage [Ue] |
100 (unshielded) m |
Input voltage (AC = sinusoidal) [Ue] |
|
Rated frequency |
4 |
Input current at signal 1 |
from power supply: no between inputs: no from the outputs: yes to base unit: yes to expansion devices: yes |
Deceleration time |
24 V DC |
Cable length |
Signal 0: ≦ 5 (I1 - I4) Signal 1: ≧ 15 (I1 - I4) V DC |
Number |
3.3 (I1 – I4) mA |
Outputs in groups of |
type 0.1 (0 -> 1) type 0.2 (1 -> 0) ms |
Parallel switching of outputs for increased output |
100 (unshielded) m |
Protection of an output relay |
|
Potential isolation |
4 |
Contacts >Conventional thermal current (10 A UL) |
from power supply: no between inputs: no from the outputs: yes to base unit: yes to expansion devices: yes |
Contacts >Recommended for load: 12 V AC/DC |
24 V AC |
Contacts >Rated impulse withstand voltage Uimp of contact coil |
Status 0: ≦ 5 (I1 - I8) Condition 1: ≧ 14 (I1 - I4) V |
Contacts >Rated operational voltage [Ue] |
50/60 Hz |
Rated insulation voltage [Ui] |
I1 - I4: 3.5 (at 24 VAC/DC) mA |
Safe isolation according to EN 50178 |
type 25⁄21 (0 - > 1/1 -> 0, 50/60Hz) ms |
Making capacity >AC–-15, 250 V AC, 3 A (600 ops./h) [Operations] |
40 (unshielded) m |
Making capacity >DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] |
|
Breaking capacity >AC-15, 250 V AC, 3 A (600 Ops./h) [Operations] |
4 |
Breaking capacity >DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] |
1 |
Filament bulb load >1000 W at 230/240 V AC [Operations] |
Not permitted |
Filament bulb load >500 W at 115/120 V AC [Operations] |
B16 circuit breaker or 8 A (T) fuse |
Fluorescent lamp load >Fluorescent lamp load 10 x 58 W at 230/240 V AC >With upstream electrical device [Operations] |
Safe isolation according to EN 50178: 300 V AC Basic isolation: 600 V AC from power supply: yes From the inputs: yes between outputs: yes to expansion devices: yes |
Fluorescent lamp load >Fluorescent lamp load 10 x 58 W at 230/240 V AC >Uncompensated [Operations] |
5 A |
Fluorescent lamp load >Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations] |
> 500 mA |
Switching frequency >Mechanical operations |
6 kV |
Switching frequency >Switching frequency |
240 V AC |
Switching frequency >Resistive load/lamp load |
240 V AC |
Switching frequency >Inductive load |
300 between coil and contact 300 between two contacts V AC |
UL/CSA >Uninterrupted current at 240 V AC |
300000 |
UL/CSA >Uninterrupted current at 24 V DC |
200000 |
UL/CSA >AC >Control Circuit Rating Codes (utilization category) |
300000 |
UL/CSA >AC >Max. rated operational voltage |
200000 |
UL/CSA >AC >max. thermal continuous current cos ϕ = 1 at B 300 |
25000 |
UL/CSA >AC >max. make/break cos ϕ ≠ capacity 1 at B 300 |
25000 |
UL/CSA >DC >Control Circuit Rating Codes (utilization category) |
25000 |
UL/CSA >DC >Max. rated operational voltage |
25000 |
UL/CSA >DC >Max. thermal uninterrupted current at R 300 |
25000 |
UL/CSA >DC >Max. make/break capacity at R 300 |
10 x 106 |
Power loss [P] |
10 Hz |
Static heat dissipation, non-current-dependent [Pvs] |
2 Hz |
Operating ambient temperature min. |
0.5 Hz |
Operating ambient temperature max. |
5 A |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
5 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
B 300 Light Pilot Duty |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
300 V AC |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
5 A |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
3600/360 VA |
10.2 Strength of materials and parts >10.2.5 Lifting |
R 300 Light Pilot Duty |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
300 V DC |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
1 A |
10.3 Degree of protection of ASSEMBLIES |
28/28 VA |
10.4 Clearances and creepage distances |
|
10.5 Protection against electric shock |
2 W |
10.6 Incorporation of switching devices and components |
|
10.7 Internal electrical circuits and connections |
2 W |
10.8 Connections for external conductors |
-25 °C |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
+55 °C |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
|
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Meets the product standard´s requirements. |
10.13 Mechanical function |
Meets the product standard´s requirements. |
Supply voltage AC 50 Hz |
Does not apply, since the entire switchgear needs to be evaluated. |
Supply voltage AC 60 Hz |
Does not apply, since the entire switchgear needs to be evaluated. |
Supply voltage DC |
Meets the product standard´s requirements. |
Voltage type of supply voltage |
Meets the product standard´s requirements. |
Switching current |
Meets the product standard´s requirements. |
Number of analogue inputs |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of analogue outputs |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of digital inputs |
Is the panel builder´s responsibility. |
Number of digital outputs |
Is the panel builder´s responsibility. |
With relay output |
Is the panel builder´s responsibility. |
Number of HW-interfaces industrial Ethernet |
Is the panel builder´s responsibility. |
Number of interfaces PROFINET |
Is the panel builder´s responsibility. |
Number of HW-interfaces RS-232 |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Number of HW-interfaces RS-422 |
Is the panel builder´s responsibility. |
Number of HW-interfaces RS-485 |
Is the panel builder´s responsibility. |
Number of HW-interfaces serial TTY |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of HW-interfaces USB |
|
Number of HW-interfaces parallel |
|
Number of HW-interfaces Wireless |
20.4 - 28.8 V |
Number of HW-interfaces other |
20.4 - 28.8 V |
With optical interface |
10.2 - 28.8 V |
Supporting protocol for TCP/IP |
AC/DC |
Supporting protocol for PROFIBUS |
5 A |
Supporting protocol for CAN |
0 |
Supporting protocol for INTERBUS |
0 |
Supporting protocol for ASI |
4 |
Supporting protocol for KNX |
4 |
Supporting protocol for MODBUS |
Yes |
Supporting protocol for Data-Highway |
0 |
Supporting protocol for DeviceNet |
0 |
Supporting protocol for SUCONET |
0 |
Supporting protocol for LON |
0 |
Supporting protocol for PROFINET IO |
0 |
Supporting protocol for PROFINET CBA |
0 |
Supporting protocol for SERCOS |
0 |
Supporting protocol for Foundation Fieldbus |
0 |
Supporting protocol for EtherNet/IP |
0 |
Supporting protocol for AS-Interface Safety at Work |
2 |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for INTERBUS-Safety |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supporting protocol for other bus systems |
No |
Radio standard Bluetooth |
No |
Radio standard WLAN 802.11 |
No |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
IO link master |
No |
Redundancy |
No |
With display |
No |
Degree of protection (IP) |
No |
Basic device |
No |
Expandable |
No |
Expansion device |
No |
With timer |
No |
Rail mounting possible |
No |
Wall mounting/direct mounting |
No |
Front build in possible |
No |
Rack-assembly possible |
No |
Suitable for safety functions |
No |
Category according to EN 954-1 |
No |
SIL according to IEC 61508 |
No |
Performance level acc. EN ISO 13849-1 |
No |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Explosion safety category for gas |
No |
Explosion safety category for dust |
No |
Width |
No |
Height |
IP20 |
Depth |
No |
UL File No. |
Yes |
UL Category Control No. |
Yes |
North America Certification |
No |
Degree of Protection |
Yes |