Basic function |
easyE4 base device |
Description |
Electronic control relay with diagnostic LEDs with Ethernet interface Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225) Rated operating voltage 12V DC, 24V DC or 24V AC 8 digital inputs, No. of these can be used as analog inputs - 4 Digital outputs: 4 relays Screw terminals Delivery with customized user program is possible via Item (Y7) -2010781 EASY-COMBINATION |
Digital |
|
of which can be used as analog |
8 |
Quantity of outputs |
4 |
Real time clock |
|
Expansions |
Relay: 4 |
Supply voltage |
|
Software |
✔ |
Connection type |
Expandable networkable (Ethernet) |
Standards |
12/24 V DC 24 V AC |
Approvals >Approvals |
EASYSOFT-SWLIC/easySoft 7 |
Approvals >certificate |
screw terminal |
Approvals >shipping classification |
|
Approvals |
EN 61000-6-2 EN 61000-6-3 IEC 60068-2-6 IEC 60068-2-27 IEC 60068-2-30 IEC 61131-2 EN 61010 EN 50178 |
Dimensions (W x H x D) |
cULus |
Weight |
CE |
Mounting |
DNV GL |
Connection type |
|
Ethernet >Connections |
71.5 x 90 x 58 mm |
Ethernet >Cable |
0.192 kg |
Screw terminals >Solid |
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Screw terminals >flexible |
screw terminal |
Screw terminals >Solid or flexible conductor, with ferrule |
RJ45 plug, 8-pin |
Screw terminals >Solid or stranded |
CAT5 |
Screw terminals >Standard screwdriver |
|
Screw terminals >Tightening torque |
0.2 - 4 mm2 |
Screw terminals >Stripping length |
0.2 - 2.5 mm2
|
Status indicator (LED) |
0,2 - 2,5 mm2
|
Operating ambient temperature |
22 - 12 AWG |
Condensation |
0.8 x 3.5 mm |
Storage [ϑ] |
0.5 - 0.7 Nm |
relative humidity |
6.5 mm |
Air pressure (operation) |
|
Protection type (IEC/EN 60529, EN50178, VBG 4) |
Power/RUN Ethernet |
Vibrations |
|
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms |
-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Drop to IEC/EN 60068-2-31 [Drop height] |
Take appropriate measures to prevent condensation |
Free fall, packaged (IEC/EN 60068-2-32) |
-40 - +70 °C |
Mounting position |
in accordance with IEC 60068-2-30, IEC 60068-2-78 5 - 95 % |
Overvoltage category/pollution degree |
795 - 1080 hPa |
Electrostatic discharge (ESD) >applied standard |
|
Electrostatic discharge (ESD) >Air discharge |
IP20 |
Electrostatic discharge (ESD) >Contact discharge |
In accordance with IEC 60068-2-6 constant amplitude 0.15 mm: 10 - 57 constant acceleration 2 g: 57 - 150 Hz |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 |
18 Impacts |
Radio interference suppression |
50 mm |
Burst |
0.3 m |
power pulses (Surge) |
Vertical or horizontal |
Immunity to line-conducted interference to (IEC/EN 61000-4-6) |
|
Clearance in air and creepage distances |
III/2 |
Insulation resistance |
according to IEC EN 61000-4-2 |
Back-up of real-time clock |
8 kV |
Accuracy of real-time clock to inputs |
6 kV |
Accuracy of timing relays (of values) |
0.8 - 1.0 GHz: 10 1.4 - 2 GHz: 3 2.0 - 2.7 GHz: 1 V/m |
Resolution >Range “S” |
EN 61000-6-3 Class B |
Resolution >Range “M:S” |
according to IEC/EN 61000-4-4 Supply cables: 2 Signal cables: 2 kV |
Resolution >Range “H:M” |
according to IEC/EN 61000-4-5 1 kV (supply cables, symmetrical) 2 kV (supply cables, asymmetrical) |
Rated operational voltage [Ue] |
10 V |
Permissible range [Ue] |
|
Residual ripple |
nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Protection against polarity reversal |
per EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Frequency |
|
Input current |
|
Voltage dips |
① Backup time (hours) with fully charged double layer capacitor ② Service life (years) |
Fuse |
typ. ± 2 (± 0.2 h⁄Year) s/day |
Power loss [P] |
depending on ambient air temperature fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible |
Heat dissipation at 24 V DC |
|
Number |
± 0.02 % |
Potential isolation |
5 ms |
Rated operational voltage [Ue] |
1 s |
Input voltage |
1 min |
Input current at signal 1 |
|
Deceleration time |
12/24 DC (-15/+20%) 24 AC (-15/+10%) V |
Cable length |
10.2 - 28.8 V DC 20.4 - 26.4 V AC |
Frequency counter >Note |
≦ 5 % |
Incremental counter >Note |
yes |
Rapid counter inputs >Note |
50/60 (± 5%) Hz |
Number |
max. 200 mA at 12 V DC max. 125 mA at 24 V DC |
Inputs can be used as analog inputs |
≤ 20 ms at 24 V AC 10 ms at 24 V DC 1 ms at 12 V DC ms |
Potential isolation |
≧ 1A (T) A |
Rated operational voltage [Ue] |
Normally 3 W |
Input voltage |
3 W |
Input current at signal 1 |
|
Deceleration time |
8 |
Cable length |
from power supply: no to the memory card: no to Ethernet: yes between inputs: no from the outputs: yes to expansion devices: yes |
Frequency counter >Number |
12 V DC |
Frequency counter >Counter frequency |
Condition 0: ≦ 5 (I1 - I8) Condition 1: ≧ 8 (I1 - I8) V DC |
Frequency counter >Pulse shape |
1.75 mA (I1 - I4) 0.9 mA (I5 - I8) mA |
Frequency counter >Pulse pause ratio |
20 (0 -> 1/1 -> 0, Debounce ON) type 0.015 (0 -> 1/1 -> 0, Debounce OFF) ms |
Frequency counter >Cable length |
100 (unshielded) m |
Incremental counter >Number of counter inputs |
Notes on this, see under Digital inputs 24 V DC |
Incremental counter >Value range |
Notes on this, see under Digital inputs 24 V DC |
Incremental counter >Counter frequency |
Notes on this, see under Digital inputs 24 V DC |
Incremental counter >Pulse shape |
|
Incremental counter >Signal offset |
8 |
Incremental counter >Pulse pause ratio |
4 (I5, I6, I7, I8) |
Incremental counter >Cable length |
from power supply: no to the memory card: no to Ethernet: yes between inputs: no from the outputs: yes to expansion devices: yes |
Rapid counter inputs >Number |
24 V DC |
Rapid counter inputs >Value range |
Signal 0: ≦ 5 (I1 - I8) Condition 1: ≧ 15 (I1 - I8) V DC |
Rapid counter inputs >Counter frequency |
3.3 (I1 – I4) 1.8 (I5 – I8) mA |
Rapid counter inputs >Pulse shape |
20 (0 -> 1/1 -> 0, Debounce ON) type 0.015 (0 -> 1/1 -> 0, Debounce OFF) ms |
Rapid counter inputs >Pulse pause ratio |
100 (unshielded) m |
Rapid counter inputs >Cable length |
4 (I1, I2, I3, I4) |
Number |
≦ 5 kHz |
Potential isolation |
Square |
Rated operational voltage [Ue] |
1:1 |
Input voltage (AC = sinusoidal) [Ue] |
≦ 20 (screened) m |
Rated frequency |
2 (I1 + I2, I3 + I4) |
Input current at signal 1 |
-2147483648 to +2147483647 |
Deceleration time |
≦ 5 kHz |
Cable length |
Square |
Number |
90° |
Potential isolation |
1:1 |
Input type |
≦ 20 (screened) m |
Signal range |
4 (I1, I2, I3, I4) |
Resolution |
-2147483648 to +2147483647 |
Input impedance |
≦ 10 kHz |
Accuracy of actual value >two devices from series |
Square |
Accuracy of actual value >Within a single device |
1:1 |
Conversion time, analog/digital |
≦ 20 (screened) m |
Input current |
|
Cable length |
8 |
Number |
from power supply: no to the memory card: no to Ethernet: yes between inputs: no from the outputs: yes to expansion devices: yes |
Outputs in groups of |
24 V AC |
Parallel switching of outputs for increased output |
Status 0: ≦ 5 (I1 - I8) Condition 1: ≧ 14 (I1 - I8) V |
Protection of an output relay |
50/60 Hz |
Potential isolation |
I1 - I4: 3.5 (at 24 VAC/DC) I5 - I8: 1.8 (at 24 VAC/DC) mA |
Contacts >Conventional thermal current (10 A UL) |
45/38 (0 -> 1/1 -> 0, debounce ON 50/60Hz) type 25⁄21 (0 - > 1/1 -> 0, debounce OFF 50/60Hz) ms |
Contacts >Recommended for load: 12 V AC/DC |
40 (unshielded) m |
Contacts >Rated impulse withstand voltage Uimp of contact coil |
|
Contacts >Rated operational voltage [Ue] |
4 (I5, I6, I7, I8) |
Rated insulation voltage [Ui] |
from power supply: no to the memory card: no to Ethernet: yes between inputs: no from the outputs: yes to expansion devices: yes |
Safe isolation according to EN 50178 |
DC voltage |
Making capacity >AC–-15, 250 V AC, 3 A (600 ops./h) [Operations] |
0-10 V DC |
Making capacity >DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] |
12 Bit (value 0 - 4095) |
Breaking capacity >AC-15, 250 V AC, 3 A (600 Ops./h) [Operations] |
13.3 kΩ |
Breaking capacity >DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] |
± 3 , ± 0.12 V % |
Filament bulb load >1000 W at 230/240 V AC [Operations] |
± 2, ± 0.12 V % |
Filament bulb load >500 W at 115/120 V AC [Operations] |
each CPU cycle ms |
Fluorescent lamp load >Fluorescent lamp load 10 x 58 W at 230/240 V AC >With upstream electrical device [Operations] |
< 1 mA |
Fluorescent lamp load >Fluorescent lamp load 10 x 58 W at 230/240 V AC >Uncompensated [Operations] |
≦ 30, screened m |
Fluorescent lamp load >Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations] |
|
Switching frequency >Mechanical operations |
4 |
Switching frequency >Switching frequency |
1 |
Switching frequency >Resistive load/lamp load |
Not allowed |
Switching frequency >Inductive load |
Miniature circuit-breaker B16 or slow-blow 8 A fuse |
UL/CSA >Uninterrupted current at 240 V AC |
Safe isolation according to EN 50178: 300 V AC Basic isolation: 600 V AC from power supply: yes From the inputs: yes between outputs: yes to Ethernet: yes to expansion devices: yes |
UL/CSA >Uninterrupted current at 24 V DC |
8 A |
UL/CSA >AC >Control Circuit Rating Codes (utilization category) |
> 500 mA |
UL/CSA >AC >Max. rated operational voltage |
6 kV |
UL/CSA >AC >max. thermal continuous current cos ϕ = 1 at B 300 |
240 V AC |
UL/CSA >AC >max. make/break cos ϕ ≠ capacity 1 at B 300 |
240 V AC |
UL/CSA >DC >Control Circuit Rating Codes (utilization category) |
300 between coil and contact 300 between two contacts V AC |
UL/CSA >DC >Max. rated operational voltage |
300000 |
UL/CSA >DC >Max. thermal uninterrupted current at R 300 |
200000 |
UL/CSA >DC >Max. make/break capacity at R 300 |
300000 |
Power loss [P] |
200000 |
Data transfer rate |
25000 |
Connections |
25000 |
Cable |
25000 |
Static heat dissipation, non-current-dependent [Pvs] |
25000 |
Operating ambient temperature min. |
25000 |
Operating ambient temperature max. |
10 x 106 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
10 Hz |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
2 Hz |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0.5 Hz |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
10 A |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
8 A |
10.2 Strength of materials and parts >10.2.5 Lifting |
B 300 Light Pilot Duty |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
300 V AC |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
5 A |
10.3 Degree of protection of ASSEMBLIES |
3600/360 VA |
10.4 Clearances and creepage distances |
R 300 Light Pilot Duty |
10.5 Protection against electric shock |
300 V DC |
10.6 Incorporation of switching devices and components |
1 A |
10.7 Internal electrical circuits and connections |
28/28 VA |
10.8 Connections for external conductors |
|
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
3 W |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
|
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
10/100 Mbit/s |
10.10 Temperature rise |
RJ45 plug, 8-pin |
10.11 Short-circuit rating |
CAT5 |
10.12 Electromagnetic compatibility |
|
10.13 Mechanical function |
3 W |
Supply voltage AC 50 Hz |
-25 °C |
Supply voltage AC 60 Hz |
+55 °C |
Supply voltage DC |
|
Voltage type of supply voltage |
Meets the product standard´s requirements. |
Switching current |
Meets the product standard´s requirements. |
Number of analogue inputs |
Meets the product standard´s requirements. |
Number of analogue outputs |
Meets the product standard´s requirements. |
Number of digital inputs |
Meets the product standard´s requirements. |
Number of digital outputs |
Does not apply, since the entire switchgear needs to be evaluated. |
With relay output |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of HW-interfaces industrial Ethernet |
Meets the product standard´s requirements. |
Number of interfaces PROFINET |
Meets the product standard´s requirements. |
Number of HW-interfaces RS-232 |
Meets the product standard´s requirements. |
Number of HW-interfaces RS-422 |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of HW-interfaces RS-485 |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of HW-interfaces serial TTY |
Is the panel builder´s responsibility. |
Number of HW-interfaces USB |
Is the panel builder´s responsibility. |
Number of HW-interfaces parallel |
Is the panel builder´s responsibility. |
Number of HW-interfaces Wireless |
Is the panel builder´s responsibility. |
Number of HW-interfaces other |
Is the panel builder´s responsibility. |
With optical interface |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Supporting protocol for TCP/IP |
Is the panel builder´s responsibility. |
Supporting protocol for PROFIBUS |
Is the panel builder´s responsibility. |
Supporting protocol for CAN |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Supporting protocol for INTERBUS |
|
Supporting protocol for ASI |
|
Supporting protocol for KNX |
20.4 - 28.8 V |
Supporting protocol for MODBUS |
20.4 - 28.8 V |
Supporting protocol for Data-Highway |
10.2 - 28.8 V |
Supporting protocol for DeviceNet |
AC/DC |
Supporting protocol for SUCONET |
8 A |
Supporting protocol for LON |
4 |
Supporting protocol for PROFINET IO |
0 |
Supporting protocol for PROFINET CBA |
8 |
Supporting protocol for SERCOS |
4 |
Supporting protocol for Foundation Fieldbus |
Yes |
Supporting protocol for EtherNet/IP |
1 |
Supporting protocol for AS-Interface Safety at Work |
0 |
Supporting protocol for DeviceNet Safety |
0 |
Supporting protocol for INTERBUS-Safety |
0 |
Supporting protocol for PROFIsafe |
0 |
Supporting protocol for SafetyBUS p |
0 |
Supporting protocol for other bus systems |
0 |
Radio standard Bluetooth |
0 |
Radio standard WLAN 802.11 |
0 |
Radio standard GPRS |
1 |
Radio standard GSM |
No |
Radio standard UMTS |
Yes |
IO link master |
No |
Redundancy |
No |
With display |
No |
Degree of protection (IP) |
No |
Basic device |
No |
Expandable |
Yes |
Expansion device |
No |
With timer |
No |
Rail mounting possible |
No |
Wall mounting/direct mounting |
No |
Front build in possible |
No |
Rack-assembly possible |
No |
Suitable for safety functions |
No |
Category according to EN 954-1 |
No |
SIL according to IEC 61508 |
No |
Performance level acc. EN ISO 13849-1 |
No |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Explosion safety category for gas |
No |
Explosion safety category for dust |
No |
Width |
No |
Height |
No |
Depth |
No |
UL File No. |
No |
UL Category Control No. |
No |
North America Certification |
No |
Degree of Protection |
No |