| Product range |
Control relays easyE4 |
| Subrange |
easyE4 analog input/output enhancements |
| Basic function |
easyE4 extensions |
| Description |
Input/output extension for easyE4 control relay Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225) Rated operating voltage 24V DC Analog inputs: 4 Analog outputs: 2 Screw terminals |
| Inputs expansion (number) |
|
| Analog |
Analog: 4 |
| Display |
4 |
| Software |
|
| Supply voltage |
with diagnostic LED |
| For use with |
EASYSOFT-SWLIC/easySoft 7 |
| Standards |
24 V DC |
Approvals >Approvals |
easyE4 |
Approvals >certificate |
|
Approvals >shipping classification |
EN 61000-6-2 EN 61000-6-3 IEC 60068-2-6 IEC 60068-2-27 IEC 60068-2-30 IEC 61131-2 EN 61010 EN 50178 |
| Approvals |
cULus |
| Dimensions (W x H x D) |
CE |
| Weight |
DNV GL |
| Mounting |
 |
| Connection type |
35.5 x 90 x 58 mm |
Screw terminals >Solid |
0.088 kg |
Screw terminals >flexible |
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Screw terminals >Solid or flexible conductor, with ferrule |
screw terminal |
Screw terminals >Solid or stranded |
|
Screw terminals >Standard screwdriver |
0.2 - 4 mm2 |
Screw terminals >Tightening torque |
0.2 - 2.5 mm2
|
Screw terminals >Stripping length |
0,2 - 2,5 mm2
|
| Operating ambient temperature |
22 - 12 AWG |
| Condensation |
0.8 x 3.5 mm |
| Storage [ϑ] |
0.5 - 0.7 Nm |
| relative humidity |
6.5 mm |
| Air pressure (operation) |
|
| Protection type (IEC/EN 60529, EN50178, VBG 4) |
-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
| Vibrations |
Take appropriate measures to prevent condensation |
| Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms |
-40 - +70 °C |
| Drop to IEC/EN 60068-2-31 [Drop height] |
in accordance with IEC 60068-2-30, IEC 60068-2-78 5 - 95 % |
| Free fall, packaged (IEC/EN 60068-2-32) |
795 - 1080 hPa |
| Mounting position |
|
| Overvoltage category/pollution degree |
IP20 |
Electrostatic discharge (ESD) >applied standard |
In accordance with IEC 60068-2-6 constant amplitude 0.15 mm: 10 - 57 constant acceleration 2 g: 57 - 150 Hz |
Electrostatic discharge (ESD) >Air discharge |
18 Impacts |
Electrostatic discharge (ESD) >Contact discharge |
50 mm |
| Electromagnetic fields (RFI) to IEC EN 61000-4-3 |
0.3 m |
| Radio interference suppression |
Vertical or horizontal |
| Burst |
|
| power pulses (Surge) |
III/2 |
| Immunity to line-conducted interference to (IEC/EN 61000-4-6) |
according to IEC EN 61000-4-2 |
| Clearance in air and creepage distances |
8 kV |
| Insulation resistance |
6 kV |
| Rated operational voltage [Ue] |
0.8 - 1.0 GHz: 10 1.4 - 2 GHz: 3 2.0 - 2.7 GHz: 1 V/m |
| Permissible range [Ue] |
EN 61000-6-3 Class B |
| Residual ripple |
according to IEC/EN 61000-4-4 Supply cables: 2 Signal cables: 2 kV |
| Protection against polarity reversal |
according to IEC/EN 61000-4-5 0.5 kV (supply cables, symmetrical) 1 kV (supply cables, asymmetrical) |
| Input current |
10 V |
| Voltage dips |
|
| Fuse |
nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Power loss [P] |
in accordance with EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Heat dissipation at 24 V DC |
|
| Number |
24 DC (-15/+20%) V |
| Potential isolation |
20.4 - 28.8 V DC |
| Input type |
≦ 5 % |
| Signal range |
yes |
| Resolution |
max. 100 mA at Ue |
| Input impedance |
≤ 10 ms |
| Cable length |
≧ 1A (T) A |
| Number |
Normally 2.5 W |
| Potential isolation |
2.5 W |
| Output type |
|
| Signal range |
4 |
| Resolution |
from power supply: no to the in/outputs: no to expansion devices: yes |
Accuracy >-25 °C - 55 °C |
Voltage or current, selectable per input |
| Cable length |
0-10 V DC 0 - 20 mA 4 - 20 mA |
| Power loss [P] |
12 Bit (value 0 - 4095) |
| Static heat dissipation, non-current-dependent [Pvs] |
12.122 kΩ |
| Operating ambient temperature min. |
≦ 10, screened m |
| Operating ambient temperature max. |
|
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
2 |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
from power supply: no to the in/outputs: no to the expansion units: yes |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Voltage or current, selectable per input |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0-10 V DC 0 - 20 mA 4 - 20 mA |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
12 Bit (value 0 - 4095) |
10.2 Strength of materials and parts >10.2.5 Lifting |
1 % |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
≦ 10, shielded m |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
|
| 10.3 Degree of protection of ASSEMBLIES |
2.5 W |
| 10.4 Clearances and creepage distances |
|
| 10.5 Protection against electric shock |
2.5 W |
| 10.6 Incorporation of switching devices and components |
-25 °C |
| 10.7 Internal electrical circuits and connections |
+55 °C |
| 10.8 Connections for external conductors |
|
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
| 10.10 Temperature rise |
Meets the product standard´s requirements. |
| 10.11 Short-circuit rating |
Meets the product standard´s requirements. |
| 10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
| 10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
| Supply voltage AC 50 Hz |
Meets the product standard´s requirements. |
| Supply voltage AC 60 Hz |
Meets the product standard´s requirements. |
| Supply voltage DC |
Meets the product standard´s requirements. |
| Voltage type of supply voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
| Switching current |
Does not apply, since the entire switchgear needs to be evaluated. |
| Number of analogue inputs |
Is the panel builder´s responsibility. |
| Number of analogue outputs |
Is the panel builder´s responsibility. |
| Number of digital inputs |
Is the panel builder´s responsibility. |
| Number of digital outputs |
Is the panel builder´s responsibility. |
| With relay output |
Is the panel builder´s responsibility. |
| Number of HW-interfaces industrial Ethernet |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| Number of interfaces PROFINET |
Is the panel builder´s responsibility. |
| Number of HW-interfaces RS-232 |
Is the panel builder´s responsibility. |
| Number of HW-interfaces RS-422 |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Number of HW-interfaces RS-485 |
|
| Number of HW-interfaces serial TTY |
|
| Number of HW-interfaces USB |
0 - 0 V |
| Number of HW-interfaces parallel |
0 - 0 V |
| Number of HW-interfaces Wireless |
20.4 - 28.8 V |
| Number of HW-interfaces other |
DC |
| With optical interface |
0.5 A |
| Supporting protocol for TCP/IP |
4 |
| Supporting protocol for PROFIBUS |
2 |
| Supporting protocol for CAN |
0 |
| Supporting protocol for INTERBUS |
0 |
| Supporting protocol for ASI |
No |
| Supporting protocol for KNX |
0 |
| Supporting protocol for MODBUS |
0 |
| Supporting protocol for Data-Highway |
0 |
| Supporting protocol for DeviceNet |
0 |
| Supporting protocol for SUCONET |
0 |
| Supporting protocol for LON |
0 |
| Supporting protocol for PROFINET IO |
0 |
| Supporting protocol for PROFINET CBA |
0 |
| Supporting protocol for SERCOS |
0 |
| Supporting protocol for Foundation Fieldbus |
2 |
| Supporting protocol for EtherNet/IP |
No |
| Supporting protocol for AS-Interface Safety at Work |
No |
| Supporting protocol for DeviceNet Safety |
No |
| Supporting protocol for INTERBUS-Safety |
No |
| Supporting protocol for PROFIsafe |
No |
| Supporting protocol for SafetyBUS p |
No |
| Supporting protocol for other bus systems |
No |
| Radio standard Bluetooth |
No |
| Radio standard WLAN 802.11 |
No |
| Radio standard GPRS |
No |
| Radio standard GSM |
No |
| Radio standard UMTS |
No |
| IO link master |
No |
| Redundancy |
No |
| With display |
No |
| Degree of protection (IP) |
No |
| Basic device |
No |
| Expandable |
No |
| Expansion device |
No |
| With timer |
No |
| Rail mounting possible |
No |
| Wall mounting/direct mounting |
No |
| Front build in possible |
No |
| Rack-assembly possible |
No |
| Suitable for safety functions |
No |
| Category according to EN 954-1 |
No |
| SIL according to IEC 61508 |
No |
| Performance level acc. EN ISO 13849-1 |
No |
| Appendant operation agent (Ex ia) |
No |
| Appendant operation agent (Ex ib) |
No |
| Explosion safety category for gas |
No |
| Explosion safety category for dust |
IP20 |
| Width |
No |
| Height |
Yes |
| Depth |
Yes |
| UL File No. |
No |
| UL Category Control No. |
Yes |
| North America Certification |
Yes |
| Degree of Protection |
No |