Eaton-T5B-7-SOND*/Z
907974 T5B-7-SOND*/Z

Non-standard switch, T5B, 63 A, rear mounting, 7 contact unit(s)Non-standard switch, Product range: Non-standard switch, Part group reference: T5B, Notes: customized version according to form, Degree of Protection: Front IP65, Design: rear mounting, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 30 kW, Rated uninterrupted current: Iu = 63 A, 7 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Non-standard switch, T5B, 63 A, rear mounting, 7 contact unit(s)
Non-standard switch, Product range: Non-standard switch, Part group reference: T5B, Notes: customized version according to form, Degree of Protection: Front IP65, Design: rear mounting, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 30 kW, Rated uninterrupted current: Iu = 63 A, 7 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Product range Non-standard switch
Part group reference T5B
Notes customized version according to form
Degree of Protection Front IP65
Design rear mounting
400 V [P] 000Z080
Rated uninterrupted current [Iu] 30 kW
Note on rated uninterrupted current !u 63 A
Number of contact units Rated uninterrupted current Iu is specified for max. cross-section.
Standards 7 contact unit(s)
Climatic proofing IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Ambient temperature
>Open
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Enclosed
-25 - +50 °C
Overvoltage category/pollution degree -25 - +40 °C
Rated impulse withstand voltage [Uimp] III/3
Mechanical shock resistance 6000 V AC
Mounting position 15 g
Electrical characteristics
>Rated operational voltage [Ue]
As required
Electrical characteristics
>Rated uninterrupted current [Iu]
690 V AC
Electrical characteristics
>Note on rated uninterrupted current !u
63 A
Load rating with intermittent operation, class 12
>AB 25 % DF
Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
>AB 40 % DF
2 x Ie
Load rating with intermittent operation, class 12
>AB 60 % DF
1.6 x Ie
Short-circuit rating
>Fuse
1.3 x Ie
Rated short-time withstand current (1 s current) [Icw ] 80 A gG/gL
Note on rated short-time withstand current lcw 1300 Arms
Rated conditional short-circuit current [Iq] Current for a time of 1 second
cos ϕ rated making capacity as per IEC 60947-3 2 kA
Rated breaking capacity cos ϕ to IEC 60947-3
>230 V
800 A
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
520 A
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
600 A
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
480 A
Safe isolation to EN 61140
>between the contacts
340 A
Safe isolation to EN 61140
>Current heat loss per contact at Ie
440 V AC
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
4.5 W
Lifespan, mechanical [Operations] 4.5 CO
Maximum operating frequency [Operations/h] > 0.5 x 106
AC
>AC-3
>Rating, motor load switch [P]
>220 V 230 V [P]
1200
AC
>AC-3
>Rating, motor load switch [P]
>230 V Star-delta [P]
15 kW
AC
>AC-3
>Rating, motor load switch [P]
>400 V 415 V [P]
18.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>400 V Star-delta [P]
22 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V [P]
30 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V Star-delta [P]
22 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V [P]
37 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V Star-delta [P]
15 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V [Ie]
22 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V star-delta [Ie]
51 A
AC
>AC-3
>Rated operational current motor load switch
>400V 415 V [Ie]
63 A
AC
>AC-3
>Rated operational current motor load switch
>400 V star-delta [Ie]
41 A
AC
>AC-3
>Rated operational current motor load switch
>500 V [Ie ]
63 A
AC
>AC-3
>Rated operational current motor load switch
>500 V star-delta [Ie ]
33 A
AC
>AC-3
>Rated operational current motor load switch
>690 V [Ie]
57.2 A
AC
>AC-3
>Rated operational current motor load switch
>690 V star-delta [Ie]
17 A
AC
>AC-21A
>Rated operational current switch
>440 V [Ie]
29.4 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>230 V [P]
63 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
18.5 kW
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
30 kW
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
22 kW
AC
>AC-23A
>Rated operational current motor load switch
>230 V [Ie]
22 kW
AC
>AC-23A
>Rated operational current motor load switch
>400 V 415 V [Ie]
63 A
AC
>AC-23A
>Rated operational current motor load switch
>500 V [Ie]
63 A
AC
>AC-23A
>Rated operational current motor load switch
>690 V [Ie]
33 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Rated operational current [Ie]
23.8 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Voltage per contact pair in series
63 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Rated operational current [Ie]
60 V
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Contacts
50 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Rated operational current [Ie]
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Contacts
50 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Rated operational current [Ie]
2 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Contacts
50 A
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Rated operational current [Ie]
3 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Contacts
25 A
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Rated operational current [Ie]
3 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Contacts
20 A
DC
>DC-13, Control switches L/R = 50 ms
>Rated operational current [Ie]
6 Quantity
DC
>DC-13, Control switches L/R = 50 ms
>Voltage per contact pair in series
25 A
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 24 V
Solid or stranded < 10 -5, < 1 fault in 100000 operations HF
Flexible with ferrules to DIN 46228 1 x (2,5 - 35)
2 x (2,5 - 16) mm2
Terminal screw 1 x (1 - 25)
2 x (1.5 - 10) mm2
Tightening torque for terminal screw M6
Notes 4 Nm
Terminal capacity
>Terminal screw
B10d values as per EN ISO 13849-1, table C1
Rated operational current for specified heat dissipation [In] M6
Heat dissipation per pole, current-dependent [Pvid] 63 A
Equipment heat dissipation, current-dependent [Pvid] 4.5 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. -25 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
+50 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
UV resistance only in connection with protective shield.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Version as main switch The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Version as maintenance-/service switch No
Version as safety switch No
Version as emergency stop installation No
Version as reversing switch No
Number of switches No
Max. rated operation voltage Ue AC 1
Rated operating voltage 690 V
Rated permanent current Iu 690 - 690 V
Rated permanent current at AC-23, 400 V 63 A
Rated permanent current at AC-21, 400 V 63 A
Rated operation power at AC-3, 400 V 63 A
Rated short-time withstand current lcw 22 kW
Rated operation power at AC-23, 400 V 1.3 kA
Switching power at 400 V 30 kW
Conditioned rated short-circuit current Iq 30 kW
Number of poles 2 kA
Number of auxiliary contacts as normally closed contact 0
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as change-over contact 0
Motor drive optional 0
Motor drive integrated No
Voltage release optional No
Device construction No
Suitable for ground mounting Built-in device fixed built-in technique
Suitable for front mounting 4-hole Yes
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting No
Colour control element Yes
Type of control element Black
Interlockable Toggle
Type of electrical connection of main circuit No
Degree of protection (IP), front side Screw connection
Degree of protection (NEMA) IP65

Benzer Ürünler

Eaton-T5-7-SOND*/V/SVB
Eaton
Eaton-T5-6-SOND*/V/SVB
Eaton
Eaton-T5-7-SOND*/EA/SVB
Eaton
Eaton-T5-6-SOND*/EA/SVB
Eaton
Eaton-T5-5-SOND*/EA/SVB
Eaton
Eaton-T5B-8-SOND*/Z
Eaton
Eaton-T5B-7-SOND*/Z
Eaton
Eaton-T5B-4-SOND*/EA/SVB
Eaton
Eaton-T5B-3-SOND*/EA/SVB
Eaton
Eaton-T5B-2-SOND*/EA/SVB
Eaton
Eaton-T5B-1-SOND*/E
Eaton
Eaton-T3-11-SOND*/Z
Eaton