Standart olmayan anahtar, T5, 100 A, arkadan montaj, Temel anahtar, 10 kontak ünitesi Standart olmayan anahtar, Ürün yelpazesi: Standart olmayan anahtar, Parça grubu referansı: T5, Notlar: forma göre özelleştirilmiş versiyon, Tasarım: arkadan montaj, Temel anahtar, Motor gücü AC-23A, 50 - 60 Hz 400 V: P = 55 kW, Nominal kesintisiz akım: Iu = 100 A, 10 kontak ünitesi, Standartlar: IEC/EN 60947, VDE 0660, IEC/EN 60204, IEC/EN 60947-3'e uygun yük ayırıcı
Standart olmayan anahtar, T5, 100 A, arkadan montaj, Temel anahtar, 10 kontak ünitesi
Standart olmayan anahtar, Ürün yelpazesi: Standart olmayan anahtar, Parça grubu referansı: T5, Notlar: forma göre özelleştirilmiş versiyon, Tasarım: arkadan montaj, Temel anahtar, Motor gücü AC-23A, 50 - 60 Hz 400 V: P = 55 kW, Nominal kesintisiz akım: Iu = 100 A, 10 kontak ünitesi, Standartlar: IEC/EN 60947, VDE 0660, IEC/EN 60204, IEC/EN 60947-3'e uygun yük ayırıcı
Product range | Non-standard switch |
Part group reference | T5 |
Notes | customized version according to form |
Design | rear mounting Basic switch |
400 V [P] | 55 kW |
Rated uninterrupted current [Iu] | 100 A |
Note on rated uninterrupted current !u | Rated uninterrupted current Iu is specified for max. cross-section. |
Number of contact units | 10 contact unit(s) |
Standards | IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Open |
-25 - +50 °C |
Ambient temperature >Enclosed |
-25 - +40 °C |
Overvoltage category/pollution degree | III/3 |
Rated impulse withstand voltage [Uimp] | 6000 V AC |
Mechanical shock resistance | 15 g |
Mounting position | As required |
Electrical characteristics >Rated operational voltage [Ue] |
690 V AC |
Electrical characteristics >Rated uninterrupted current [Iu] |
100 A |
Electrical characteristics >Note on rated uninterrupted current !u |
Rated uninterrupted current Iu is specified for max. cross-section. |
Load rating with intermittent operation, class 12 >AB 25 % DF |
2 x Ie |
Load rating with intermittent operation, class 12 >AB 40 % DF |
1.6 x Ie |
Load rating with intermittent operation, class 12 >AB 60 % DF |
1.3 x Ie |
Short-circuit rating >Fuse |
100 A gG/gL |
Rated short-time withstand current (1 s current) [Icw ] | 1700 Arms |
Note on rated short-time withstand current lcw | Current for a time of 1 second |
Rated conditional short-circuit current [Iq] | 2 kA |
cos ϕ rated making capacity as per IEC 60947-3 | 950 A |
Rated breaking capacity cos ϕ to IEC 60947-3 >230 V |
760 A |
Rated breaking capacity cos ϕ to IEC 60947-3 >400/415 V |
740 A |
Rated breaking capacity cos ϕ to IEC 60947-3 >500 V |
590 A |
Rated breaking capacity cos ϕ to IEC 60947-3 >690 V |
420 A |
Safe isolation to EN 61140 >between the contacts |
440 V AC |
Safe isolation to EN 61140 >Current heat loss per contact at Ie |
7.5 W |
Safe isolation to EN 61140 >Current heat loss per auxiliary circuit at Ie (AC-15/230 V) |
7.5 CO |
Lifespan, mechanical [Operations] | > 0.5 x 106 |
Maximum operating frequency [Operations/h] | 1200 |
AC >AC-3 >Rating, motor load switch [P] >220 V 230 V [P] |
22 kW |
AC >AC-3 >Rating, motor load switch [P] >230 V Star-delta [P] |
30 kW |
AC >AC-3 >Rating, motor load switch [P] >400 V 415 V [P] |
30 kW |
AC >AC-3 >Rating, motor load switch [P] >400 V Star-delta [P] |
45 kW |
AC >AC-3 >Rating, motor load switch [P] >500 V [P] |
30 kW |
AC >AC-3 >Rating, motor load switch [P] >500 V Star-delta [P] |
45 kW |
AC >AC-3 >Rating, motor load switch [P] >690 V [P] |
15 kW |
AC >AC-3 >Rating, motor load switch [P] >690 V Star-delta [P] |
22 kW |
AC >AC-3 >Rated operational current motor load switch >230 V [Ie] |
71 A |
AC >AC-3 >Rated operational current motor load switch >230 V star-delta [Ie] |
100 A |
AC >AC-3 >Rated operational current motor load switch >400V 415 V [Ie] |
55 A |
AC >AC-3 >Rated operational current motor load switch >400 V star-delta [Ie] |
95.3 A |
AC >AC-3 >Rated operational current motor load switch >500 V [Ie ] |
44 A |
AC >AC-3 >Rated operational current motor load switch >500 V star-delta [Ie ] |
76.2 A |
AC >AC-3 >Rated operational current motor load switch >690 V [Ie] |
17 A |
AC >AC-3 >Rated operational current motor load switch >690 V star-delta [Ie] |
29.4 A |
AC >AC-21A >Rated operational current switch >440 V [Ie] |
100 A |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >230 V [P] |
30 kW |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >400 V 415 V [P] |
55 kW |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >500 V [P] |
37 kW |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >690 V [P] |
30 kW |
AC >AC-23A >Rated operational current motor load switch >230 V [Ie] |
100 A |
AC >AC-23A >Rated operational current motor load switch >400 V 415 V [Ie] |
100 A |
AC >AC-23A >Rated operational current motor load switch >500 V [Ie] |
55 A |
AC >AC-23A >Rated operational current motor load switch >690 V [Ie] |
32 A |
DC >DC-1, Load-break switches L/R = 1 ms >Rated operational current [Ie] |
80 A |
DC >DC-1, Load-break switches L/R = 1 ms >Voltage per contact pair in series |
60 V |
Control circuit reliability at 24 V DC, 10 mA [Fault probability] | < 10 -5, < 1 fault in 100000 operations HF |
Solid or stranded | 1 x (2,5 - 35) 2 x (2,5 - 16) mm2 |
Flexible with ferrules to DIN 46228 | 1 x (1 - 25) 2 x (1.5 - 10) mm2 |
Terminal screw | M6 |
Tightening torque for terminal screw | 4 Nm |
Notes | B10d values as per EN ISO 13849-1, table C1 |
Terminal capacity >Terminal screw |
M6 |
Rated operational current for specified heat dissipation [In] | 100 A |
Heat dissipation per pole, current-dependent [Pvid] | 7.5 W |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +50 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
UV resistance only in connection with protective shield. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Version as main switch | No |
Version as maintenance-/service switch | No |
Version as safety switch | No |
Version as emergency stop installation | No |
Version as reversing switch | No |
Number of switches | 1 |
Max. rated operation voltage Ue AC | 690 V |
Rated operating voltage | 690 - 690 V |
Rated permanent current Iu | 100 A |
Rated permanent current at AC-23, 400 V | 100 A |
Rated permanent current at AC-21, 400 V | 100 A |
Rated operation power at AC-3, 400 V | 30 kW |
Rated short-time withstand current lcw | 1.7 kA |
Rated operation power at AC-23, 400 V | 55 kW |
Switching power at 400 V | 55 kW |
Conditioned rated short-circuit current Iq | 2 kA |
Number of poles | 0 |
Number of auxiliary contacts as normally closed contact | 0 |
Number of auxiliary contacts as normally open contact | 0 |
Number of auxiliary contacts as change-over contact | 0 |
Motor drive optional | No |
Motor drive integrated | No |
Voltage release optional | No |
Device construction | Built-in device fixed built-in technique |
Suitable for ground mounting | No |
Suitable for front mounting 4-hole | No |
Suitable for front mounting centre | No |
Suitable for distribution board installation | No |
Suitable for intermediate mounting | No |
Colour control element | Black |
Type of control element | Other |
Interlockable | No |
Type of electrical connection of main circuit | Screw connection |
Degree of protection (IP), front side | IP00 |
Degree of protection (NEMA) | Other |
Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.