alt
alt

T0-2-15432/SE1
197431 T0-2-15432/SE1
Y7-197431

Değiştirme anahtarları, T0, 20 A, yüzeye montaj, 2 kontak ünitesi, Kontaklar: 4, 45 °, bakımlı, 0 (Kapalı) konumunda, HAND-0-AUTO, çelik muhafazada, Tasarım numarası 15432

Değiştirme anahtarları, T0, 20 A, yüzeye montaj, 2 kontak ünitesi, Kontaklar: 4, 45 °, bakımlı, 0 (Kapalı) konumunda, HAND-0-AUTO, çelik muhafazada, Tasarım numarası 15432

Product range Control switches
Part group reference T0
Basic function Changeoverswitches
Notes with black thumb grip and front plate
Contacts in steel enclosure
Degree of Protection 4
Design IP65
Contact sequence 000Z083
Switching angle surface mounting
Switching performance 000Z078
Design number 115S293-2
Front plate no. 45 °
front plate maintained
With 0 (Off) position
400 V [P] 15432
Rated uninterrupted current [Iu] 115K028
Note on rated uninterrupted current !u HAND-0-AUTO
Number of contact units 5.5 kW
Standards 20 A
Ambient temperature
>Enclosed
Rated uninterrupted current Iu is specified for max. cross-section.
Overvoltage category/pollution degree 2 contact unit(s)
Rated impulse withstand voltage [Uimp] IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch disconnector in accordance with IEC/EN 60947-3
Mechanical shock resistance -25 - +40 °C
Mounting position III/3
Electrical characteristics
>Rated operational voltage [Ue]
6000 V AC
Electrical characteristics
>Rated uninterrupted current [Iu]
15 g
Electrical characteristics
>Note on rated uninterrupted current !u
As required
Load rating with intermittent operation, class 12
>AB 25 % DF
690 V AC
Load rating with intermittent operation, class 12
>AB 40 % DF
20 A
Load rating with intermittent operation, class 12
>AB 60 % DF
Rated uninterrupted current Iu is specified for max. cross-section.
Short-circuit rating
>Fuse
2 x Ie
Rated short-time withstand current (1 s current) [Icw ] 1.6 x Ie
Note on rated short-time withstand current lcw 1.3 x Ie
Rated conditional short-circuit current [Iq] 20 A gG/gL
cos ϕ rated making capacity as per IEC 60947-3 320 Arms
Rated breaking capacity cos ϕ to IEC 60947-3
>230 V
Current for a time of 1 second
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
6 kA
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
130 A
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
100 A
Safe isolation to EN 61140
>between the contacts
110 A
Safe isolation to EN 61140
>Current heat loss per contact at Ie
80 A
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
60 A
Lifespan, mechanical [Operations] 440 V AC
Maximum operating frequency [Operations/h] 0.6 W
AC
>AC-3
>Rating, motor load switch [P]
>220 V 230 V [P]
0.6 CO
AC
>AC-3
>Rating, motor load switch [P]
>230 V Star-delta [P]
> 0.4 x 106
AC
>AC-3
>Rating, motor load switch [P]
>400 V 415 V [P]
1200
AC
>AC-3
>Rating, motor load switch [P]
>400 V Star-delta [P]
3 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V [P]
5.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V Star-delta [P]
5.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V [P]
7.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V Star-delta [P]
5.5 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V [Ie]
7.5 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V star-delta [Ie]
4 kW
AC
>AC-3
>Rated operational current motor load switch
>400V 415 V [Ie]
5.5 kW
AC
>AC-3
>Rated operational current motor load switch
>400 V star-delta [Ie]
11.5 A
AC
>AC-3
>Rated operational current motor load switch
>500 V [Ie ]
20 A
AC
>AC-3
>Rated operational current motor load switch
>500 V star-delta [Ie ]
11.5 A
AC
>AC-3
>Rated operational current motor load switch
>690 V [Ie]
20 A
AC
>AC-3
>Rated operational current motor load switch
>690 V star-delta [Ie]
9 A
AC
>AC-21A
>Rated operational current switch
>440 V [Ie]
15.6 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>230 V [P]
4.9 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
8.5 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
20 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
3 kW
AC
>AC-23A
>Rated operational current motor load switch
>230 V [Ie]
5.5 kW
AC
>AC-23A
>Rated operational current motor load switch
>400 V 415 V [Ie]
7.5 kW
AC
>AC-23A
>Rated operational current motor load switch
>500 V [Ie]
5.5 kW
AC
>AC-23A
>Rated operational current motor load switch
>690 V [Ie]
13.3 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Rated operational current [Ie]
13.3 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Voltage per contact pair in series
13.3 A
DC
>DC-21A [Ie ]
>Rated operational current [Ie]
7.6 A
DC
>DC-21A [Ie ]
>Contacts
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Rated operational current [Ie]
60 V
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Contacts
1 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Rated operational current [Ie]
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Contacts
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Rated operational current [Ie]
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Contacts
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Rated operational current [Ie]
2 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Contacts
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Rated operational current [Ie]
3 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Contacts
5 A
DC
>DC-13, Control switches L/R = 50 ms
>Rated operational current [Ie]
3 Quantity
DC
>DC-13, Control switches L/R = 50 ms
>Voltage per contact pair in series
5 A
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 5 Quantity
Solid or stranded 10 A
Flexible with ferrules to DIN 46228 32 V
Terminal screw < 10 -5, < 1 fault in 100000 operations HF
Tightening torque for terminal screw 1 x (1 - 2,5)
2 x (1 - 2,5) mm2
Notes 1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity
>Terminal screw
M3.5
Terminal capacity
>Tightening torque
1 Nm
Version as main switch B10d values as per EN ISO 13849-1, table C1
Version as maintenance-/service switch M3.5
Version as safety switch 8.83 lb-in
Version as emergency stop installation No
Version as reversing switch Yes
Number of switches No
Max. rated operation voltage Ue AC No
Rated operating voltage No
Rated permanent current Iu 1
Rated permanent current at AC-23, 400 V 690 V
Rated permanent current at AC-21, 400 V 690 - 690 V
Rated operation power at AC-3, 400 V 20 A
Rated short-time withstand current lcw 13.3 A
Rated operation power at AC-23, 400 V 20 A
Switching power at 400 V 5.5 kW
Conditioned rated short-circuit current Iq 0.32 kA
Number of poles 5.5 kW
Number of auxiliary contacts as normally closed contact 5.5 kW
Number of auxiliary contacts as normally open contact 6 kA
Number of auxiliary contacts as change-over contact 4
Motor drive optional 0
Motor drive integrated 0
Voltage release optional 0
Device construction No
Suitable for ground mounting No
Suitable for front mounting 4-hole No
Suitable for front mounting centre Complete device in housing
Suitable for distribution board installation Yes
Suitable for intermediate mounting No
Colour control element No
Type of control element No
Interlockable No
Type of electrical connection of main circuit Black
Degree of protection (IP), front side Short thumb-grip
Degree of protection (NEMA) No

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton