Product range |
Main switch maintenance switch Repair switch |
Part group reference |
P1 |
Stop Function |
STOP function |
Information about equipment supplied |
With black rotary handle and locking ring |
Notes |
Auxiliary contact or neutral conductor fitted by user. |
Number of poles |
UL/CSA |
Degree of Protection |
3 pole |
Design |
1 N/O |
Contact sequence |
1 N/C |
Function |
IP65 |
400 V [P] |
|
Rated uninterrupted current [Iu] |
surface mounting |
Note on rated uninterrupted current !u |
|
Standards |
|
Climatic proofing |
|
Ambient temperature >Enclosed |
15 kW |
Overvoltage category/pollution degree |
32 A |
Rated impulse withstand voltage [Uimp] |
Rated uninterrupted current Iu is specified for max. cross-section. |
Mechanical shock resistance |
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnector according to IEC/EN 60947-3 |
Mounting position |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical variables >Number of poles |
-25 - +40 °C |
Mechanical variables >Auxiliary contacts1 N/O
Mechanical variables >Auxiliary contacts 1 N/C
Electrical characteristics >Rated operational voltage [Ue] |
III/3 |
Electrical characteristics >Rated uninterrupted current [Iu] |
6000 V AC |
Electrical characteristics >Note on rated uninterrupted current !u |
15 g |
Load rating with intermittent operation, class 12 >AB 25 % DF |
As required |
Load rating with intermittent operation, class 12 >AB 40 % DF |
3 pole |
Load rating with intermittent operation, class 12 >AB 60 % DF |
1 N/O |
Short-circuit rating >Fuse |
1 N/C |
Rated short-time withstand current (1 s current) [Icw
] |
690 V AC |
Note on rated short-time withstand current lcw |
32 A |
Rated conditional short-circuit current [Iq] |
Rated uninterrupted current Iu is specified for max. cross-section. |
cos ϕ rated making capacity as per IEC 60947-3 |
2 x Ie |
Rated breaking capacity cos ϕ to IEC 60947-3 >230 V |
1.6 x Ie |
Rated breaking capacity cos ϕ to IEC 60947-3 >400/415 V |
1.3 x Ie |
Rated breaking capacity cos ϕ to IEC 60947-3 >500 V |
50 A gG/gL |
Rated breaking capacity cos ϕ to IEC 60947-3 >690 V |
640 Arms |
Safe isolation to EN 61140 >between the contacts |
Current for a time of 1 second |
Safe isolation to EN 61140 >Current heat loss per contact at Ie |
80 kA |
Safe isolation to EN 61140 >Current heat loss per auxiliary circuit at Ie (AC-15/230 V) |
320 A |
Lifespan, mechanical [Operations] |
260 A |
Maximum operating frequency [Operations/h] |
300 A |
AC >AC-3 >Rating, motor load switch [P] >220 V 230 V [P] |
290 A |
AC >AC-3 >Rating, motor load switch [P] >400 V 415 V [P] |
250 A |
AC >AC-3 >Rating, motor load switch [P] >500 V [P] |
440 V AC |
AC >AC-3 >Rating, motor load switch [P] >690 V [P] |
1.8 W |
AC >AC-3 >Rated operational current motor load switch >230 V [Ie] |
0.2 CO |
AC >AC-3 >Rated operational current motor load switch >400V 415 V [Ie] |
> 0.3 x 106 |
AC >AC-3 >Rated operational current motor load switch >500 V [Ie
] |
1200 |
AC >AC-3 >Rated operational current motor load switch >690 V [Ie] |
7.5 kW |
AC >AC-21A >Rated operational current switch >440 V [Ie] |
13 kW |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >230 V [P] |
18.5 kW |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >400 V 415 V [P] |
15 kW |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >500 V [P] |
26.4 A |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >690 V [P] |
26.4 A |
AC >AC-23A >Rated operational current motor load switch >230 V [Ie] |
23.4 A |
AC >AC-23A >Rated operational current motor load switch >400 V 415 V [Ie] |
14.7 A |
AC >AC-23A >Rated operational current motor load switch >500 V [Ie] |
32 A |
AC >AC-23A >Rated operational current motor load switch >690 V [Ie] |
7.5 kW |
DC >DC-1, Load-break switches L/R = 1 ms >Rated operational current [Ie] |
15 kW |
DC >DC-1, Load-break switches L/R = 1 ms >Voltage per contact pair in series |
18.5 kW |
DC >DC-23A, motor load switch
L/R = 15 ms >24 V >Rated operational current [Ie] |
15 kW |
DC >DC-23A, motor load switch
L/R = 15 ms >24 V >Contacts |
32 A |
DC >DC-23A, motor load switch
L/R = 15 ms >48 V >Rated operational current [Ie] |
32 A |
DC >DC-23A, motor load switch
L/R = 15 ms >48 V >Contacts |
30 A |
DC >DC-23A, motor load switch
L/R = 15 ms >60 V >Rated operational current [Ie] |
19.8 A |
DC >DC-23A, motor load switch
L/R = 15 ms >60 V >Contacts |
32 A |
DC >DC-23A, motor load switch
L/R = 15 ms >120 V >Rated operational current [Ie] |
60 V |
DC >DC-23A, motor load switch
L/R = 15 ms >120 V >Contacts |
25 A |
Control circuit reliability at 24 V DC, 10 mA [Fault probability] |
1 Quantity |
Solid or stranded |
25 A |
Flexible with ferrules to DIN 46228 |
2 Quantity |
Terminal screw |
25 A |
Tightening torque for terminal screw |
2 Quantity |
Notes |
12 A |
Contacts >Rated operational voltage [Ue] |
3 Quantity |
Contacts >Rated uninterrupted current max. >Main conducting paths >General use |
< 10 -5, < 1 fault in 100000 operations HF
|
Contacts >Rated uninterrupted current max. >Auxiliary contacts >General Use [IU] |
1 x (1,5 - 6) 2 x (1,5 - 6) mm2
|
Contacts >Rated uninterrupted current max. >Auxiliary contacts >Pilot Duty |
1 x (1 - 4) 2 x (1 - 4) mm2 |
Switching capacity >Maximum motor rating >Single-phase >120 V AC |
M4 |
Switching capacity >Maximum motor rating >Single-phase >200 V AC |
1.6 Nm |
Switching capacity >Maximum motor rating >Single-phase >240 V AC |
B10d values as per EN ISO 13849-1, table C1 |
Switching capacity >Maximum motor rating >Three-phase >200 V AC |
600 V AC |
Switching capacity >Maximum motor rating >Three-phase >240 V AC |
30 A |
Switching capacity >Maximum motor rating >Three-phase >480 V AC |
10 A |
Switching capacity >Maximum motor rating >Three-phase >600 V AC |
A 600 P 600 |
Short Circuit Current Rating >Basic Rating |
1 HP |
Short Circuit Current Rating >max. Fuse |
2 HP |
Short Circuit Current Rating >High fault rating |
3 HP |
Short Circuit Current Rating >max. Fuse |
3 HP |
Terminal capacity >Solid or flexible conductor with ferrule |
7.5 HP |
Terminal capacity >Terminal screw |
10 HP |
Terminal capacity >Tightening torque |
15 HP |
Rated operational current for specified heat dissipation [In] |
5 kA |
Heat dissipation per pole, current-dependent [Pvid] |
110 A |
Equipment heat dissipation, current-dependent [Pvid] |
10 kA |
Static heat dissipation, non-current-dependent [Pvs] |
50, Class J A |
Heat dissipation capacity [Pdiss] |
14 - 8 AWG |
Operating ambient temperature min. |
M4 |
Operating ambient temperature max. |
14.1 lb-in |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
32 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
1.8 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-25 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+40 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
UV resistance only in connection with protective shield. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Version as main switch |
Is the panel builder´s responsibility. |
Version as maintenance-/service switch |
Is the panel builder´s responsibility. |
Version as safety switch |
Is the panel builder´s responsibility. |
Version as emergency stop installation |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Version as reversing switch |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of switches |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Max. rated operation voltage Ue AC |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated operating voltage |
Yes |
Rated permanent current Iu |
Yes |
Rated permanent current at AC-23, 400 V |
No |
Rated permanent current at AC-21, 400 V |
No |
Rated operation power at AC-3, 400 V |
No |
Rated short-time withstand current lcw |
1 |
Rated operation power at AC-23, 400 V |
690 V |
Switching power at 400 V |
690 - 690 V |
Conditioned rated short-circuit current Iq |
32 A |
Number of poles |
32 A |
Number of auxiliary contacts as normally closed contact |
32 A |
Number of auxiliary contacts as normally open contact |
13 kW |
Number of auxiliary contacts as change-over contact |
0.64 kA |
Motor drive optional |
15 kW |
Motor drive integrated |
15 kW |
Voltage release optional |
80 kA |
Device construction |
3 |
Suitable for ground mounting |
1 |
Suitable for front mounting 4-hole |
1 |
Suitable for front mounting centre |
0 |
Suitable for distribution board installation |
No |
Suitable for intermediate mounting |
No |
Colour control element |
No |
Type of control element |
Complete device in housing |
Interlockable |
Yes |
Type of electrical connection of main circuit |
No |
Degree of protection (IP), front side |
No |
Degree of protection (NEMA) |
No |
Product Standards |
No |
UL File No. |
Black |
UL Category Control No. |
Door coupling rotary drive |
CSA File No. |
Yes |
CSA Class No. |
Screw connection |
North America Certification |
IP65 |
Specially designed for North America |
12 |
Suitable for |
UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking |
Degree of Protection |
E36332 |