alt
alt

MSC-D-16-M15(24VDC)
100415 MSC-D-16-M15(24VDC)
100415

DOL marş motoru, 380 V 400 V 415 V: 7,5 kW, Ir= 10 - 16 A, 24 V DC, DC DOL yolverici, Temel cihaz: MSC, Notlar: IE3 verimlilik sınıfına sahip motorlar için uygun değildir, Motor değerleri Motor gücü AC-3 380 V 400 V 415 V: P= 7,5 kW, Aşırı yük bobinlerinin ayar aralığı: Ir= 10 - 16 A, Koordinasyon: Koordinasyon türü “1”, Çalıştırma gerilimi: 24 V DC, DC, Standartlar: IEC/EN 60947-4-1, VDE 0660

DOL marş motoru, 380 V 400 V 415 V: 7,5 kW, Ir= 10 - 16 A, 24 V DC, DC
DOL yolverici, Temel cihaz: MSC, Notlar: IE3 verimlilik sınıfına sahip motorlar için uygun değildir, Motor değerleri Motor gücü AC-3 380 V 400 V 415 V: P= 7,5 kW, Aşırı yük bobinlerinin ayar aralığı: Ir= 10 - 16 A, Koordinasyon: Koordinasyon türü “1”, Çalıştırma gerilimi: 24 V DC, DC, Standartlar: IEC/EN 60947-4-1, VDE 0660

Basic function DOL starters (complete devices)
Basic device MSC
Notes Not suitable for motors with efficiency class IE3.
Connection technique Screw terminals
Connection to SmartWire-DT no
Motor rating [P]
>AC-3
>380 V 400 V 415 V [P]
Rated operational current
>AC-3
>380 V 400 V 415 V [Ie]
7.5 kW
Rated short-circuit current 380 - 415 V [Iq ] 15.2 A
Setting range of overload releases [Ir] 50 kA
Coordination
Contact sequence 10 - 16 A
Actuating voltage Type of coordination “1”
Motor-protective circuit-breakers 1210SWI-16
Contactor 24 V DC
DOL starter wiring set

Mechanical connection element and electrical electric contact module
DC
Notes PKZM0-16 Type
Notes DILM15-10(...) Part no.
Standards PKZM0-XDM12 Type
Mounting position

BK25/3-PKZ0-E extension terminal and if necessary B3.../...-PKZ0 three-phase commoning link can be added to motor-starter combinations to make Type F starters in accordance with UL508.

Altitude

The DOL starters (complete units) consist of a PKZM0 motor protective circuit breaker and a DILM contactor.

With the adapter-less top-hat rail mounting of starters up to 15 A, only the motor protective circuit breaker on the top-hat rail requires an adapter. The contactors are provided with mechanical support via a mechanical connection element.

Control wire guide with max. 6 conductors up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter.

The connection of the main circuit between PKZ and contactor is established with electrical contact modules.

When using the auxiliary contacts DILA‐XHIT… (→ 101042) the plug-in electrical connector can be removed without the removal of the front mounting auxiliary contact.

Ambient temperature
Rated impulse withstand voltage [Uimp] IEC/EN 60947-4-1, VDE 0660
Overvoltage category/pollution degree 2115DRW-5
Rated operational voltage [Ue] Max. 2000 m
Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
-25 - +55
Motor protective circuit breaker PKZM0, PKE
DILM contactors
>Current heat loss
>Current heat loss at Ie to AC-3/400 V
6000 V AC
DC operated [Sealing] III/3
Auxiliary contacts
>Pilot Duty
>AC operated
230 - 415 V
Auxiliary contacts
>Pilot Duty
>DC operated
15 A
Auxiliary contacts
>General Use
>AC
Auxiliary contacts
>General Use
>AC
PKZM0 motor-protective circuit-breakers, see motor-protective circuit-breakers/PKZM0 product group
DILM contactors, see contactor product group
DILET timing relay, ETR, see contactors, electronic timing relays product group
Auxiliary contacts
>General Use
>DC
12 W
Auxiliary contacts
>General Use
>DC
Rated operational current for specified heat dissipation [In] 2.6 W
Heat dissipation per pole, current-dependent [Pvid]
Equipment heat dissipation, current-dependent [Pvid] A600
Static heat dissipation, non-current-dependent [Pvs] P300
Heat dissipation capacity [Pdiss] 600 V
Operating ambient temperature min. 15 A
Operating ambient temperature max. 250 V
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
1 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
15.5 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
4 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
12 W
10.2 Strength of materials and parts
>10.2.5 Lifting
2.6 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
-25 °C
10.3 Degree of protection of ASSEMBLIES +55 °C
10.4 Clearances and creepage distances
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Kind of motor starter Does not apply, since the entire switchgear needs to be evaluated.
With short-circuit release Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 50HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at DC Is the panel builder´s responsibility.
Voltage type for actuating Is the panel builder´s responsibility.
Rated operation power at AC-3, 230 V, 3-phase The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated power, 460 V, 60 Hz, 3-phase Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated power, 575 V, 60 Hz, 3-phase The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated operation current Ie
Rated operation current at AC-3, 400 V
Overload release current setting Direct starter
Rated conditional short-circuit current, type 1, 480 Y/277 V Yes
Rated conditional short-circuit current, type 1, 600 Y/347 V 0 - 0 V
Rated conditional short-circuit current, type 2, 230 V 0 - 0 V
Rated conditional short-circuit current, type 2, 400 V 24 - 24 V
Number of auxiliary contacts as normally open contact DC
Number of auxiliary contacts as normally closed contact 4 kW
Ambient temperature, upper operating limit 7.5 kW
Temperature compensated overload protection 0 kW
Release class 0 kW
Type of electrical connection of main circuit 15.2 A
Type of electrical connection for auxiliary- and control current circuit 15 A
Rail mounting possible 16 - 16 A
With transformer 0 A
Number of command positions 0 A
Suitable for emergency stop 0 A
Coordination class according to IEC 60947-4-3 0 A
Number of indicator lights 1
External reset possible 0
With fuse 60 °C
Degree of protection (IP) Yes
Degree of protection (NEMA) CLASS 10 A
Supporting protocol for TCP/IP Screw connection
Supporting protocol for PROFIBUS Screw connection
Supporting protocol for CAN Yes
Supporting protocol for INTERBUS No
Supporting protocol for ASI 0
Supporting protocol for MODBUS No
Supporting protocol for Data-Highway Class 1
Supporting protocol for DeviceNet 0
Supporting protocol for SUCONET No
Supporting protocol for LON No
Supporting protocol for PROFINET IO IP20
Supporting protocol for PROFINET CBA Other
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Width No
Height No
Depth No
Product Standards No
UL File No. No
UL Category Control No. No
CSA File No. No
CSA Class No. No
North America Certification No
Specially designed for North America No

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

PKE32/XTUCP-36
Eaton
EMT6-DB(230V)
Eaton
PKE65/XTUWCP-36
Eaton
PKE65/XTUCP-65
Eaton
MSC-D-16-M15(230V50HZ)
Eaton
MSC-D-16-M15(24VDC)
Eaton
MSC-D-10-M17(230V50HZ)
Eaton
MSC-D-12-M17(230V50HZ)