Product range |
Switch-disconnector Main switch maintenance switch |
Part group reference |
DMV |
Stop Function |
optional |
Notes |
Without rotary handle and drive shaft |
Information about equipment supplied |
visible contacts |
Number of poles |
auxiliary contact fitted by user. including connection materials |
Degree of Protection |
3P + N (solid) |
Design |
0 N/O |
Contact sequence |
0 N/C |
400 V [P] |
IP00 IP20 with terminal cover |
Rated uninterrupted current [Iu] |
surface mounting |
Note on rated uninterrupted current !u |
|
Connection technique |
|
Standards |
90 kW |
Certifications |
160 A |
Ambient temperature >Operation [ϑ] |
Rated uninterrupted current Iu is specified for max. cross-section. |
Ambient temperature >Storage [ϑ] |
Screw terminal, drilling dimension 6,5 mm |
Overvoltage category/pollution degree |
IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 |
Rated impulse withstand voltage [Uimp] |
CE, RoHs, KEMA, EAC, Lloyds |
Rated insulation voltage [Ui
] |
-25 - +55 °C |
Mounting position |
-30 - +80 °C |
Mechanical variables >Number of poles |
III/3 |
Mechanical variables >Auxiliary contacts0 N/O
Mechanical variables >Auxiliary contacts 0 N/C
Electrical characteristics >Rated operational voltage [Ue] |
8 kV |
Electrical characteristics >Rated uninterrupted current [Iu] |
1000 V |
Electrical characteristics >Note on rated uninterrupted current !u |
As required |
Short-circuit rating >fuse |
3P + N (solid) |
Short-circuit rating >Rated conditional short-circuit current [Iq] |
0 N/O |
Short-circuit rating >Breaking current |
0 N/C |
Short-circuit rating >max. let-through energy |
690 V AC |
Rated short-time withstand current (1 s current) [Icw
] |
160 A |
Note on rated short-time withstand current lcw |
Rated uninterrupted current Iu is specified for max. cross-section. |
Heat dissipation per pole, current-dependent [Pvid] |
160/100 |
Rated breaking capacity cos ϕ to IEC 60947-3 >400/415 V |
In = 160: 50 In = 100: 100 kA |
Rated breaking capacity cos ϕ to IEC 60947-3 >500 V |
In = 160: 50 In = 100: 14.5 kA |
Safe isolation to EN 61140 >Current heat loss per contact at Ie |
In = 160: 600 In = 100: 67 kA²s |
Lifespan, mechanical [Operations] |
8000 Arms |
AC >AC-21A >Rated operational current switch >400 V 415 V [Ie] |
Current for a time of 0.2 seconds |
AC >AC-21A >Rated operational current switch >500 V [Ie] |
3.9 W |
AC >AC-21A >Rated operational current switch >690 V [Ie] |
1232 A |
AC >AC-22A >Rated operational current switch >400 V 415 V [Ie] |
848 A |
AC >AC-22A >Rated operational current switch >500 V [Ie] |
3.9 W |
AC >AC-22A >Rated operational current switch >690 V [Ie] |
10000 |
AC >AC-23A >Rated operational current switch >400 V 415 V [Ie] |
160 A |
AC >AC-23A >Rated operational current switch >500 V [Ie] |
160 A |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >400 V 415 V [P] |
125 A |
AC >AC-23A >Motor rating AC-23A, 50 - 60 Hz [P] >500 V [P] |
160 A |
Flat conductor connection with busbars |
160 A |
Terminal screw |
125 A |
Notes |
154 A |
Rated operational current for specified heat dissipation [In] |
106 A |
Heat dissipation per pole, current-dependent [Pvid] |
90 kW |
Equipment heat dissipation, current-dependent [Pvid] |
75 kW |
Static heat dissipation, non-current-dependent [Pvs] |
75 mm2
|
Heat dissipation capacity [Pdiss] |
M6 x 16 |
Operating ambient temperature min. |
B10d values as per EN ISO 13849-1, table C1 |
Operating ambient temperature max. |
160 A |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
3.9 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
-25 °C |
10.2 Strength of materials and parts >10.2.5 Lifting |
+55 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Version as main switch |
Is the panel builder´s responsibility. |
Version as maintenance-/service switch |
Is the panel builder´s responsibility. |
Version as safety switch |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Version as emergency stop installation |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Version as reversing switch |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of switches |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Max. rated operation voltage Ue AC |
Yes |
Rated operating voltage |
Yes |
Rated permanent current Iu |
No |
Rated permanent current at AC-23, 400 V |
Yes |
Rated permanent current at AC-21, 400 V |
No |
Rated operation power at AC-3, 400 V |
1 |
Rated short-time withstand current lcw |
690 V |
Rated operation power at AC-23, 400 V |
690 - 690 V |
Switching power at 400 V |
160 A |
Conditioned rated short-circuit current Iq |
154 A |
Number of poles |
160 A |
Number of auxiliary contacts as normally closed contact |
0 kW |
Number of auxiliary contacts as normally open contact |
8 kA |
Number of auxiliary contacts as change-over contact |
90 kW |
Motor drive optional |
90 kW |
Motor drive integrated |
100 kA |
Voltage release optional |
3 |
Device construction |
0 |
Suitable for ground mounting |
0 |
Suitable for front mounting 4-hole |
0 |
Suitable for front mounting centre |
No |
Suitable for distribution board installation |
No |
Suitable for intermediate mounting |
No |
Colour control element |
Complete device in housing |
Type of control element |
Yes |
Interlockable |
No |
Type of electrical connection of main circuit |
No |
Degree of protection (IP), front side |
Yes |
Degree of protection (NEMA) |
No |