Variable frequency drive, 400 V AC, 3-phase, 170 A, 90 kW, IP54/NEMA12, DC link chokeVariable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 170 A, Note: Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 205 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 90 kW, 110 % Overload: P = 110 kW, 150 % Overload: IM = 161 A, 110 % Overload: IM = 196 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 110 kW, 110 % Overload: P = 132 kW, 150 % Overload: IM = 157 A, 110 % Overload: IM = 184 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 125 HP, 110 % Overload: P = 150 HP, Assigned motor rating 150 % Overload: IM = 156 A, 110 % Overload: IM = 180 A, Degree of Protection: IP54/NEMA12, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS5, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5
Variable frequency drive, 400 V AC, 3-phase, 170 A, 90 kW, IP54/NEMA12, DC link choke
Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 170 A, Note: Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 205 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 90 kW, 110 % Overload: P = 110 kW, 150 % Overload: IM = 161 A, 110 % Overload: IM = 196 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 110 kW, 110 % Overload: P = 132 kW, 150 % Overload: IM = 157 A, 110 % Overload: IM = 184 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 125 HP, 110 % Overload: P = 150 HP, Assigned motor rating 150 % Overload: IM = 156 A, 110 % Overload: IM = 180 A, Degree of Protection: IP54/NEMA12, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS5, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5
Product range | Variable frequency drives |
Part group reference (e.g. DIL) | DG1 |
Rated operational voltage [Ue] | 400 V AC, 3-phase 480 V AC, 3-phase 500 V AC, 3-phase |
Output voltage with Ve [U2] | 400 V AC, 3-phase 480 V AC, 3-phase 500 V AC, 3-phase |
Mains voltage (50/60Hz) [ULN] | 380 (-15%) - 500 (+10%) V |
At 150% overload [Ie] | |
At 110% overload [Ie] | 170 A |
Note | 205 A |
Note | Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload |
Note | |
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
150 % Overload [P] | Overload cycle for 60 s every 600 s |
110 % Overload [P] | at 400 V, 50 Hz |
150 % Overload [IM] | 90 kW |
110 % Overload [IM] | 110 kW |
Note | 161 A |
150 % Overload [P] | 196 A |
110 % Overload [P] | at 500 V, 50 Hz |
150 % Overload [IM] | 110 kW |
110 % Overload [IM] | 132 kW |
Note | 157 A |
150 % Overload [P] | 184 A |
110 % Overload [P] | at 480 V, 60 Hz |
150 % Overload [IM] | 125 HP |
110 % Overload [IM] | 150 HP |
Degree of Protection | 156 A |
Interface/field bus (built-in) | 180 A |
Fieldbus connection (optional) | IP54/NEMA12 |
Fitted with | Modbus RTU Modbus TCP BACnet MS/TP Ethernet IP |
Parameterization | PROFIBUS CANopen® DeviceNet SmartWire-DT |
Frame size | Radio interference suppression filter Additional PCB protection Multi-line graphic display DC link choke |
Connection to SmartWire-DT | Keypad Fieldbus Power Xpert inControl |
Standards | FS5 |
Certifications | yes in conjunction with DXG-NET-SWD SmartWire DT module |
Production quality | |
Climatic proofing [ρw] | Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5 |
Air quality | CE, UL, cUL, c-Tick, UkrSEPRO, EAC |
Ambient temperature >Operating ambient temperature min. |
RoHS, ISO 9001 |
Ambient temperature >Operating ambient temperature max. |
< 95%, average relative humidity (RH), non-condensing, non-corrosive % |
Ambient temperature >operation (110 % overload) [ϑ] |
3C2, 3S2 |
Ambient temperature | -10 °C |
Ambient temperature >Storage [ϑ] |
+50 °C |
Overvoltage category | -10 - +40 °C |
Pollution degree | Operation with 110 % overload (1 min./10 min.): -10 to +40 (max. +55 with 1% derating per Kelvin above limit) Operation with 150% overload (1 min./10 min.): -10 to +50 (max. +60 with 1% derating per Kelvin above limit) -20 with cold-weather mode |
Radio interference level >Radio interference class (EMC) |
-40 - +70 °C |
Radio interference level >Environment (EMC) |
III |
Radio interference level >maximum motor cable length [I] |
2 |
Mechanical shock resistance | C1 (with external filter, for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. |
Vibration | 1st and 2nd environments as per EN 61800-3 |
Mounting position | C2 ≤ 10 m C3 ≤ 50 m m |
Altitude | EN 61800-5-1, EN 60068-2-27 UPS drop test (for weights inside the UPS frame) Storage and transportation: maximum 15 g, 11 ms (inside the packaging) g |
Degree of Protection | EN 61800-5-1, EN 60068-2-6: 5 - 150 Hz Amplitude: 1 mm (peak) at 5 - 15.8 Hz Maximum acceleration amplitude: 1 g at 15.8 – 150 Hz |
Protection against direct contact | Vertical |
Supply >Rated operational voltage [Ue] |
0 - 1000 m above sea level Above 1000 m: 1% derating for every 100 m max. 3000 m (2000 m for Corner Grounded TN Systems) m |
Supply >Mains voltage (50/60Hz) [ULN] |
IP54/NEMA12 |
Supply >Input current (150% overload) [ILN] |
BGV A3 (VBG4, finger- and back-of-hand proof) |
Supply >Input current (110% overload) [ILN] |
|
Supply >System configuration |
400 V AC, 3-phase 480 V AC, 3-phase 500 V AC, 3-phase |
Supply >Supply frequency [fLN] |
380 (-15%) - 500 (+10%) V |
Supply >Frequency range [fLN] |
157 A |
Supply >Mains switch-on frequency |
189 T |
Supply >Mains current distortion [THD] |
TN-S, TN-C, TN-C-S, TT, IT |
Supply >Rated conditional short-circuit current [Iq] |
50/60 Hz |
Power section >Function |
45–66 (± 0%) Hz |
Power section >Overload current (150% overload) [IL] |
Maximum of one time every 60 seconds |
Power section >Overload current (110% overload) [IL] |
29.5 % |
Power section >max. starting current (High Overload) [IH] |
< 100 kA |
Power section >Note about max. starting current |
Variable frequency drive with internal DC link, DC link choke and IGBT inverter |
Power section >Output voltage with Ve [U2] |
255 A |
Power section >Output Frequency [f2] |
225.5 A |
Power section >Switching frequency [fPWM] |
200 % |
Power section >Operation Mode |
for 2 seconds every 20 seconds |
Power section >Frequency resolution (setpoint value) [Δf] |
400 V AC, 3-phase 480 V AC, 3-phase 500 V AC, 3-phase |
Power section >Rated operational current >At 150% overload [Ie] |
0 - 50/60 (max. 400) Hz |
Power section >Rated operational current >At 110% overload [Ie] |
3.6 adjustable 1 - 10 kHz |
Power section >Note |
U/f control Speed control with slip compensation sensorless vector control (SLV) Torque regulation |
Power section >Motor current limit [I] |
0.01 Hz |
Power section >Power loss >Heat dissipation at rated operational current Ie =150 % [PV] |
170 A |
Power section >Power loss >Heat dissipation at rated operational current Ie =110% [PV] |
205 A |
Power section >Efficiency [η] |
Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload |
Power section >Maximum leakage current to ground (PE) without motor [IPE] |
0.1 - 2 x IH (CT) A |
Power section >Fan |
1594 W |
Power section >Internal fan delivery rate |
2024 W |
Power section >Fitted with |
98.6 % |
Power section >Safety function |
7.5 mA |
Power section >Frame size |
temperature controlled externally accessible |
Motor feeder >Note |
395 m3/h |
Motor feeder >Note |
Radio interference suppression filter Additional PCB protection Multi-line graphic display DC link choke |
Motor feeder >Note |
STO (Safe Torque Off, SIL1, PLc Cat 1) |
Motor feeder >150 % Overload [P] |
FS5 |
Motor feeder >110 % Overload [P] |
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
Motor feeder >Note |
Overload cycle for 60 s every 600 s |
Motor feeder >150 % Overload [P] |
at 400 V, 50 Hz |
Motor feeder >110 % Overload [P] |
90 kW |
Motor feeder >Note |
110 kW |
Motor feeder >150 % Overload [P] |
at 500 V, 50 Hz |
Motor feeder >110 % Overload [P] |
110 kW |
Motor feeder >maximum permissible cable length [I] |
132 kW |
Motor feeder >Apparent power >Apparent power at rated operation 400 V [S] |
at 480 V, 60 Hz |
Motor feeder >Apparent power >Apparent power at rated operation 480 V [S] |
125 HP |
Motor feeder >Braking function >Standard braking torque |
150 HP |
Motor feeder >Braking function >DC braking torque |
screened: 200 m |
Motor feeder >Braking function >Braking torque with external braking resistance |
142 kVA |
Motor feeder >Braking function >Switch-on threshold for the braking transistor [UDC] |
177.5 kVA |
Motor feeder >Braking function >DC braking [%] |
max. 30 % MN |
External control voltage [Uc] | adjustable to 150 % |
Reference voltage [Us] | Max. 100% of rated operational current Ie with external braking resistor |
Analog inputs | 850 V DC V |
Analog outputs | ≦ 150, adjustable I/Ie |
Digital inputs | |
Digital outputs | 24 V DC (max. 250 mA options incl.) V |
Relay outputs | 10 V DC (max. 10 mA) V |
Interface/field bus (built-in) | 2, parameterizable, 0 - 10 V DC, 2 - 10 V DC, -10 - +10 V DC, 0/4 - 20 mA |
Expansion slots | 2, parameterizable, 0 - 10 V, 0/4 - 20 mA |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >IEC (Type B, gG), 150 % |
8, parameterizable, max. 30 V DC |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >IEC (Type B, gG), 110 % |
1, parameterizable, 24 V DC |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >UL (Class CC or J) |
3, parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 VAC) / 6 A (24 VDC) |
Power Wiring >Mains contactor >150 % overload (CT/IH, at 50 °C) |
Modbus RTU Modbus TCP BACnet MS/TP Ethernet IP |
Power Wiring >Mains contactor >110 % overload (VT/IL, at 40 °C) |
2 |
Power Wiring >Main choke >150 % overload (CT/IH, at 50 °C) |
|
Power Wiring >Main choke >110 % overload (VT/IL, at 40 °C) |
NZMC2-A200 |
Power Wiring >Radio interference suppression filter (external, 150 %) |
NZMC2-A250 |
Power Wiring >Radio interference suppression filter (external, 110 %) |
250 A |
Power Wiring >Radio interference suppression filter, low leakage currents (external, 150 %) |
DILM170 |
Power Wiring >Radio interference suppression filter, low leakage currents (external, 110 %) |
DILM185A |
Power Wiring >Note regarding radio interference suppression filter |
Integrated DC link choke, uk = 5% |
Motor feeder >motor choke >150 % overload (CT/IH, at 50 °C) |
Integrated DC link choke, uk = 5% |
Motor feeder >motor choke >110 % overload (VT/IL, at 40 °C) |
DX-EMC34-180 |
Motor feeder >Sine filter >150 % overload (CT/IH, at 50 °C) |
DX-EMC34-250 |
Motor feeder >Sine filter >110 % overload (VT/IL, at 40 °C) |
DX-EMC34-180-L |
Motor feeder >All-pole sine filter >150 % overload (CT/IH, at 50 °C) |
DX-EMC34-250-L |
Rated operational current for specified heat dissipation [In] | Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments |
Heat dissipation per pole, current-dependent [Pvid] | DX-LM3-180 |
Equipment heat dissipation, current-dependent [Pvid] | DX-LM3-220 |
Static heat dissipation, non-current-dependent [Pvs] | DX-SIN3-180 |
Heat dissipation capacity [Pdiss] | DX-SIN3-250 |
Operating ambient temperature min. | P:2 x DX-SIN3-110-A |
Operating ambient temperature max. | |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
170 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
2024 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
30.74 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-10 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+50 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Operation (with 150 % overload), allow for derating |
10.3 Degree of protection of ASSEMBLIES | |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise | Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating | Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility | Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function | Does not apply, since the entire switchgear needs to be evaluated. |
Mains voltage | Is the panel builder´s responsibility. |
Mains frequency | Is the panel builder´s responsibility. |
Number of phases input | Is the panel builder´s responsibility. |
Number of phases output | Is the panel builder´s responsibility. |
Max. output frequency | Is the panel builder´s responsibility. |
Max. output voltage | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Nominal output current I2N | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Max. output at quadratic load at rated output voltage | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Max. output at linear load at rated output voltage | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Relative symmetric net frequency tolerance | |
Relative symmetric net voltage tolerance | |
Number of analogue outputs | 323 - 550 V |
Number of analogue inputs | 50/60 Hz |
Number of digital outputs | 3 |
Number of digital inputs | 3 |
With control unit | 400 Hz |
Application in industrial area permitted | 480 V |
Application in domestic- and commercial area permitted | 205 A |
Supporting protocol for TCP/IP | 110 kW |
Supporting protocol for PROFIBUS | 180 kW |
Supporting protocol for CAN | 10 % |
Supporting protocol for INTERBUS | 10 % |
Supporting protocol for ASI | 2 |
Supporting protocol for KNX | 2 |
Supporting protocol for MODBUS | 1 |
Supporting protocol for Data-Highway | 8 |
Supporting protocol for DeviceNet | Yes |
Supporting protocol for SUCONET | Yes |
Supporting protocol for LON | Yes |
Supporting protocol for PROFINET IO | Yes |
Supporting protocol for PROFINET CBA | Yes |
Supporting protocol for SERCOS | Yes |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | Yes |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | Yes |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for BACnet | No |
Supporting protocol for other bus systems | Yes |
Number of HW-interfaces industrial Ethernet | No |
Number of interfaces PROFINET | No |
Number of HW-interfaces RS-232 | No |
Number of HW-interfaces RS-422 | Yes |
Number of HW-interfaces RS-485 | No |
Number of HW-interfaces serial TTY | No |
Number of HW-interfaces USB | No |
Number of HW-interfaces parallel | No |
Number of HW-interfaces other | No |
With optical interface | Yes |
With PC connection | Yes |
Integrated breaking resistance | 1 |
4-quadrant operation possible | 0 |
Type of converter | 0 |
Degree of protection (IP) | 0 |
Degree of protection (NEMA) | 1 |
Height | 0 |
Width | 0 |
Depth | 0 |
Product Standards | 1 |
UL File No. | No |
UL Category Control No. | Yes |
CSA File No. | No |
North America Certification | Yes |
Suitable for | U converter |
Max. Voltage Rating | IP54 |
Degree of Protection | 12 |