Variable frequency drive, 115 V AC, single-phase, 2.3 A, 0.37 kW, IP20/NEMA 0, FS1Variable frequency drive, Part group reference (e.g. DIL): DC1, Rated operational voltage: Ue = 115 V AC, single-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 110 (-10%) - 115 (+10%) V, Rated operational current At 150% overload: Ie = 2.3 A, Note: Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 0.37 kW, 150 % Overload: IM = 2 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 0.5 HP, Assigned motor rating 150 % Overload: IM = 2.2 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): SmartWire-DT, Fitted with: 7-digital display assembly, Frame size: FS1, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Variable frequency drive, 115 V AC, single-phase, 2.3 A, 0.37 kW, IP20/NEMA 0, FS1
Variable frequency drive, Part group reference (e.g. DIL): DC1, Rated operational voltage: Ue = 115 V AC, single-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 110 (-10%) - 115 (+10%) V, Rated operational current At 150% overload: Ie = 2.3 A, Note: Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 0.37 kW, 150 % Overload: IM = 2 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 0.5 HP, Assigned motor rating 150 % Overload: IM = 2.2 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): SmartWire-DT, Fitted with: 7-digital display assembly, Frame size: FS1, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Product range | Variable frequency drives |
Part group reference (e.g. DIL) | DC1 |
Rated operational voltage [Ue] | 115 V AC, single-phase |
Output voltage with Ve [U2] | 230 V AC, 3-phase |
Mains voltage (50/60Hz) [ULN] | 110 (-10%) - 115 (+10%) V |
At 150% overload [Ie] | |
Note | 2.3 A |
Note | Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +50 °C |
Note | |
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
150 % Overload [P] | Overload cycle for 60 s every 600 s |
150 % Overload [IM] | at 230 V, 50 Hz |
Note | 0.37 kW |
150 % Overload [P] | 2 A |
150 % Overload [IM] | at 220 - 240 V, 60 Hz |
Degree of Protection | 0.5 HP |
Interface/field bus (built-in) | 2.2 A |
Fieldbus connection (optional) | IP20/NEMA0 |
Fitted with | OP-Bus (RS485)/Modbus RTU, CANopen® |
Parameterization | SmartWire-DT |
Frame size | 7-digital display assembly Additional PCB protection |
Connection to SmartWire-DT | Keypad Fieldbus drivesConnect drivesConnect mobile (App) |
Standards | FS1 |
Certifications | yes in conjunction with DX-NET-SWD3 SmartWire DT module |
Production quality | |
Climatic proofing [ρw] | Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5-1 |
Air quality | CE, UL, cUL, RCM, Ukr SEPRO, EAC |
Ambient temperature >Operating ambient temperature min. |
RoHS, ISO 9001 |
Ambient temperature >Operating ambient temperature max. |
< 95%, average relative humidity (RH), non-condensing, non-corrosive % |
Ambient temperature | 3C2, 3S2 |
Ambient temperature >Storage [ϑ] |
-10 °C |
Mounting position | +50 °C |
Altitude | operation (with 150 % overload) |
Degree of Protection | -40 - +60 °C |
Protection against direct contact | Vertical |
Supply >Rated operational voltage [Ue] |
0 - 1000 m above sea level Above 1000 m: 1% derating for every 100 m max. 4000 m m |
Supply >Notes |
IP20/NEMA0 |
Supply >Mains voltage (50/60Hz) [ULN] |
BGV A3 (VBG4, finger- and back-of-hand proof) |
Supply >Input current (150% overload) [ILN] |
|
Supply >System configuration |
115 V AC, single-phase |
Supply >Supply frequency [fLN] |
The mains voltage of 115 V is raised to 230 V (output voltage) through an internal voltage double connection. |
Supply >Frequency range [fLN] |
110 (-10%) - 115 (+10%) V |
Supply >Mains switch-on frequency |
7.8 A |
Power section >Function |
AC supply systems with earthed center point |
Power section >Overload current (150% overload) [IL] |
50/60 Hz |
Power section >max. starting current (High Overload) [IH] |
48 - 62 Hz |
Power section >Note about max. starting current |
Maximum of one time every 30 seconds |
Power section >Output voltage with Ve [U2] |
Variable frequency drive with internal DC link and IGBT inverter |
Power section >Output Frequency [f2] |
3.45 A |
Power section >Switching frequency [fPWM] |
175 % |
Power section >Operation Mode |
for 2,5 seconds every 600 seconds |
Power section >Frequency resolution (setpoint value) [Δf] |
230 V AC, 3-phase |
Power section >Rated operational current >At 150% overload [Ie] |
0 - 50/60 (max. 500) Hz |
Power section >Note |
8 adjustable 4 - 32 (audible) kHz |
Power section >Power loss >Heat dissipation at rated operational current Ie =150 % [PV] |
U/f control Speed control with slip compensation sensorless vector control (SLV) PM motors Synchronous reluctance motors BLDC motors |
Power section >Efficiency [η] |
0.1 Hz |
Power section >Maximum leakage current to ground (PE) without motor [IPE] |
2.3 A |
Power section >Fitted with |
Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +50 °C |
Power section >Frame size |
18.5 W |
Motor feeder >Note |
95 % |
Motor feeder >Note |
4.8 mA |
Motor feeder >Note |
7-digital display assembly Additional PCB protection |
Motor feeder >150 % Overload [P] |
FS1 |
Motor feeder >Note |
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
Motor feeder >150 % Overload [P] |
Overload cycle for 60 s every 600 s |
Motor feeder >maximum permissible cable length [I] |
at 230 V, 50 Hz |
Motor feeder >Braking function >Standard braking torque |
0.37 kW |
Motor feeder >Braking function >DC braking torque |
at 220 - 240 V, 60 Hz |
Reference voltage [Us] | 0.5 HP |
Analog inputs | screened: 50 screened, with motor choke: 100 unscreened: 75 unscreened, with motor choke: 150 m |
Analog outputs | max. 30 % MN |
Digital inputs | max. 100% of rated operational current Ie, variable |
Digital outputs | |
Relay outputs | 10 V DC (max. 10 mA) V |
Interface/field bus (built-in) | 2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >IEC (Type B, gG), 150 % |
1, parameterizable, 0 - 10 V |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >UL (Class CC or J) |
4, parameterizable, max. 30 V DC |
Power Wiring >Mains contactor >150 % overload (CT/IH, at 50 °C) |
1, parameterizable, 24 V DC |
Power Wiring >Main choke >150 % overload (CT/IH, at 50 °C) |
1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1) |
Power Wiring >Radio interference suppression filter (external, 150 %) |
OP-Bus (RS485)/Modbus RTU, CANopen® |
Power Wiring >Note regarding radio interference suppression filter |
|
Motor feeder >motor choke >150 % overload (CT/IH, at 50 °C) |
FAZ-B16/1N |
Motor feeder >Sine filter >150 % overload (CT/IH, at 50 °C) |
15 A |
Rated operational current for specified heat dissipation [In] | DILEM-… + P1DILEM |
Heat dissipation per pole, current-dependent [Pvid] | DX-LN1-009 |
Equipment heat dissipation, current-dependent [Pvid] | DX-EMC12-014-FS1 |
Static heat dissipation, non-current-dependent [Pvs] | Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments |
Heat dissipation capacity [Pdiss] | DX-LM3-008 |
Operating ambient temperature min. | DX-SIN3-004 |
Operating ambient temperature max. | |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
7 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
18.5 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-10 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+50 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Operation (with 150 % overload) |
10.3 Degree of protection of ASSEMBLIES | |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise | Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating | Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility | Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function | Does not apply, since the entire switchgear needs to be evaluated. |
Mains voltage | Is the panel builder´s responsibility. |
Mains frequency | Is the panel builder´s responsibility. |
Number of phases input | Is the panel builder´s responsibility. |
Number of phases output | Is the panel builder´s responsibility. |
Max. output frequency | Is the panel builder´s responsibility. |
Max. output voltage | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Nominal output current I2N | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Max. output at quadratic load at rated output voltage | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Max. output at linear load at rated output voltage | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Relative symmetric net frequency tolerance | |
Relative symmetric net voltage tolerance | |
Number of analogue outputs | 99 - 126 V |
Number of analogue inputs | 50/60 Hz |
Number of digital outputs | 1 |
Number of digital inputs | 3 |
With control unit | 500 Hz |
Application in industrial area permitted | 250 V |
Application in domestic- and commercial area permitted | 2.3 A |
Supporting protocol for TCP/IP | 0.37 kW |
Supporting protocol for PROFIBUS | 0.37 kW |
Supporting protocol for CAN | 10 % |
Supporting protocol for INTERBUS | 10 % |
Supporting protocol for ASI | 1 |
Supporting protocol for KNX | 2 |
Supporting protocol for MODBUS | 1 |
Supporting protocol for Data-Highway | 4 |
Supporting protocol for DeviceNet | Yes |
Supporting protocol for SUCONET | Yes |
Supporting protocol for LON | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for SERCOS | Yes |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | Yes |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for BACnet | No |
Supporting protocol for other bus systems | No |
Number of HW-interfaces industrial Ethernet | No |
Number of interfaces PROFINET | No |
Number of HW-interfaces RS-232 | No |
Number of HW-interfaces RS-422 | Yes |
Number of HW-interfaces RS-485 | No |
Number of HW-interfaces serial TTY | No |
Number of HW-interfaces USB | No |
Number of HW-interfaces parallel | No |
Number of HW-interfaces other | No |
With optical interface | No |
With PC connection | Yes |
Integrated breaking resistance | 0 |
4-quadrant operation possible | 0 |
Type of converter | 0 |
Degree of protection (IP) | 0 |
Degree of protection (NEMA) | 1 |
Height | 0 |
Width | 0 |
Depth | 0 |
Product Standards | 0 |
UL File No. | No |
UL Category Control No. | Yes |
CSA File No. | No |
North America Certification | No |
Specially designed for North America | U converter |
Suitable for | IP20 |
Max. Voltage Rating | Other |
Degree of Protection | 184 mm |