Product range |
Electronic overload relays ZEB |
Phase-failure sensitivity |
IEC/EN 60947, VDE 0660 Part 102 |
Description |
Test/off button Reset pushbutton Manual/auto reset selectable Protection with heavy starting duty (Class 10A-30) |
Mounting type |
Separate mounting |
Earth-fault protection |
|
Overload releases [Ir
] |
none |
Contact sequence |
|
N/O = Normally open |
0.33 - 1.65 A |
N/C = Normally closed |
|
For use with |
|
Explosion protection (according to ATEX 94/9/EC) |
1 N/O |
EC-prototype test certification |
1 N/C |
Standards |
DILM17 DILM25 DILM32 DILM38 DIULM17 DIULM25 DIULM32 SDAINLM30 SDAINLM45 SDAINLM55 |
Climatic proofing |
|
Ambient temperature >Open |
II(2)GD [Ex d] [Ex e] [Ex tb] |
Ambient temperature >Ambient temperature open max. |
SIRA 13 ATEX 9348X |
Ambient temperature >Enclosed >Ambient temperature enclosed max. |
|
Mechanical shock resistance |
IEC/EN 60947, VDE 0660, UL, CSA |
Degree of Protection |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Protection against direct contact when actuated from front (EN 50274) |
-25 - +65 °C |
Altitude |
65 °C |
Rated impulse withstand voltage [Uimp] |
65 °C |
Overvoltage category/pollution degree |
15 Shock duration 10 ms according to IEC 60068-2-27 g |
Rated insulation voltage [Ui
] |
IP20 |
Rated operational voltage [Ue] |
Finger and back-of-hand proof |
Rated frequency [f] |
Max. 2000 m |
Safe isolation to EN 61140 >Between auxiliary contacts and main contacts |
|
Safe isolation to EN 61140 >Between main circuits |
6000 V AC |
Terminal capacities >Solid |
III/3 |
Terminal capacities >Solid or stranded |
690 V AC |
Stripping length |
690 V AC |
Rated impulse withstand voltage [Uimp] |
50/60 Hz |
Overvoltage category/pollution degree |
600 V AC |
Terminal capacities >Solid |
600 V AC |
Terminal capacities >Flexible with ferrule |
1 x 1.5 - 16 mm2 |
Terminal capacities >Solid or stranded |
1 x 14 - 4 AWG |
Terminal screw |
13 mm |
Tightening torque |
|
Tightening torque |
6000 V |
Stripping length |
III/3 |
Tools >Pozidriv screwdriver |
2 x (0.75 - 4) mm2 |
Tools >Standard screwdriver |
2 x (0.75 - 2.5) mm2 |
Rated insulation voltage [Ui
] |
2 x (18 - 12) AWG |
Rated operational voltage [Ue
] |
M3.5 |
Safe isolation to EN 61140 >between the auxiliary contacts |
0.8 - 1.2 Nm |
Conventional thermal current [Ith
] |
7 lb-in |
Rated operational current [Ie
] >AC-15 >Make contact >120 V [Ie
] |
8 mm |
Rated operational current [Ie
] >AC-15 >Make contact >220 V 230 V 240 V [Ie
] |
2 Size |
Rated operational current [Ie
] >AC-15 >Make contact >380 V 400 V 415 V [Ie
] |
1 x 6 mm |
Rated operational current [Ie
] >AC-15 >Make contact >500 V [Ie
] |
500 V AC |
Rated operational current [Ie
] >AC-15 >Break contact >120 V [Ie
] |
500 V AC |
Rated operational current [Ie
] >AC-15 >Break contact >220 V 230 V 240 V [Ie
] |
240 V AC |
Rated operational current [Ie
] >AC-15 >Break contact >380 V 400 V 415 V [Ie
] |
5 A |
Rated operational current [Ie
] >AC-15 >Break contact >500 V [Ie
] |
1.5 A |
Rated operational current [Ie
] >DC L/R ≦ 15 ms |
1.5 A |
Rated operational current [Ie
] >DC L/R ≦ 15 ms >24 V [Ie
] |
0.5 A |
Rated operational current [Ie
] >DC L/R ≦ 15 ms >60 V [Ie
] |
0.5 A |
Rated operational current [Ie
] >DC L/R ≦ 15 ms >110 V [Ie
] |
1.5 A |
Rated operational current [Ie
] >DC L/R ≦ 15 ms >220 V [Ie
] |
1.5 A |
Short-circuit rating without welding >max. fuse |
0.9 A |
Auxiliary contacts >Pilot Duty >AC operated |
0.8 A |
Auxiliary contacts >Pilot Duty >DC operated |
Switch-on and switch-off conditions based on DC-13, time constant as specified. |
Short Circuit Current Rating >Basic Rating >SCCR |
0.9 A |
Short Circuit Current Rating >Basic Rating >max. Fuse |
0.75 A |
Rated operational current for specified heat dissipation [In] |
0.4 A |
Heat dissipation per pole, current-dependent [Pvid] |
0.2 A |
Equipment heat dissipation, current-dependent [Pvid] |
6 A gG/gL |
Static heat dissipation, non-current-dependent [Pvs] |
|
Heat dissipation capacity [Pdiss] |
B600 |
Operating ambient temperature min. |
R300 |
Operating ambient temperature max. |
1 kA |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
6, RK5 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
1.65 A |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0.17 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0.5 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
0 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
0 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
-25 °C |
10.3 Degree of protection of ASSEMBLIES |
+65 °C |
10.4 Clearances and creepage distances |
|
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Meets the product standard´s requirements. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Adjustable current range |
Does not apply, since the entire switchgear needs to be evaluated. |
Mounting method |
Is the panel builder´s responsibility. |
Type of electrical connection of main circuit |
Is the panel builder´s responsibility. |
Number of auxiliary contacts as normally closed contact |
Is the panel builder´s responsibility. |
Number of auxiliary contacts as normally open contact |
Is the panel builder´s responsibility. |
Number of auxiliary contacts as change-over contact |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at AC 50HZ |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated control supply voltage Us at AC 60HZ |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated control supply voltage Us at DC |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Release class |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Voltage type for actuating |
|
Reset function automatic |
|
Reset function input |
0.33 - 1.65 A |
Reset function push-button |
Separate positioning |
Product Standards |
Screw connection |
UL File No. |
1 |
UL Category Control No. |
1 |
CSA File No. |
0 |
CSA Class No. |
0 - 0 V |
North America Certification |
0 - 0 V |
Specially designed for North America |
0 - 0 V |
Suitable for |
Adjustable |
Max. Voltage Rating |
Self powered |
Degree of Protection |
Yes |
Characteristic curve |
No |