Product range |
Accessories |
Accessories |
Undervoltage release |
Actuating voltage |
…V 50 Hz (24 - 500 V) |
Voltage type |
Non-standard voltages outside standard voltages |
Current actuation |
AC |
Contact sequence |
|
Connection technique |
Screw terminals |
For use with |
Undervoltage release PKZ0(4), PKE |
For use with |
PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE |
Notes |
For non-standard voltages, the required actuation voltage from the specified range (...-...V) must be indicated in the * for the part no. |
Notes |
|
| 1 Motorschutzschalter | |
|
Terminal capacities >Solid or flexible conductor, with ferrule |
Can be fitted to the left of: Motor protective circuit-breaker Cannot be combined with: A-PKZ0 shunt release When combined with circuit-breaker can be used as emergency switching-off device according to EN 60204. |
Terminal capacities >Solid or stranded |
|
Actuating voltage |
1 x (0,75 - 2,5) 2 x (0,75 - 2,5) mm2
|
Pick-up voltage |
1 x (18 - 14) 2 x (18 - 14) AWG |
Drop-out voltage |
…V 50 Hz (24 - 500 V) |
AC >Pull-in power [Pick-up] |
|
AC >Sealing power [Sealing] |
0,85 - 1,1 x Uc |
Rated operational current for specified heat dissipation [In] |
0,7- 0,35 x Uc |
Heat dissipation per pole, current-dependent [Pvid] |
|
Equipment heat dissipation, current-dependent [Pvid] |
5 VA |
Static heat dissipation, non-current-dependent [Pvs] |
3 VA |
Heat dissipation capacity [Pdiss] |
|
Operating ambient temperature min. |
0 A |
Operating ambient temperature max. |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0.5 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
-25 °C |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
+55 °C |
10.2 Strength of materials and parts >10.2.5 Lifting |
|
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at AC 50HZ |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at AC 60HZ |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at DC |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Voltage type for actuating |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Type of electric connection |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of contacts as normally open contact |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of contacts as normally closed contact |
|
Number of contacts as change-over contact |
|
Delayed |
24 - 500 V |
Suitable for power circuit breaker |
0 - 0 V |
Suitable for off-load switch |
0 - 0 V |
Suitable for motor safety switch |
AC |
Suitable for overload relay |
Screw connection |
Product Standards |
0 |
UL File No. |
0 |
UL Category Control No. |
0 |
CSA File No. |
No |
CSA Class No. |
No |
North America Certification |
No |
Specially designed for North America |
Yes |
Accessories |
No |