Product range |
Accessories |
Accessories |
Trip blocks |
Basic function |
Motor protection Motor protection for heavy starting duty |
Notes |
|
Overload releases [Ir
] >Setting range of overload releases [Ir] |
Also suitable for motors with efficiency class IE3. IE3-ready devices are identified by the logo on their packaging. |
Overload releases [Ir
] >Overload release, min. [Ir] |
|
Overload releases [Ir
] >Overload release, max. [Ir
] |
1 - 4 A |
Function |
1 A |
Rated uninterrupted current = rated operational current [Iu = Ie
] |
4 A |
AC-3 >220 V 230 V [P] |
With overload release |
AC-3 >380 V 400 V [P] |
4 A |
AC-3 >440 V [P] |
|
AC-3 >500 V [P] |
0.75 kW |
AC-3 >660 V 690 V [P] |
1.5 kW |
For use with |
1.5 kW |
Connection to SmartWire-DT |
2.2 kW |
Motor output/rated motor current |
3 kW |
Standards |
PKE12 basic device PKE32 basic device |
Climatic proofing |
no |
Ambient temperature >Storage |
Motor rating | | Rated motor current |
---|
| | AC-3 | | | | | | | | |
---|
| | 220 V 230 V 240 V | | 380 V 400 V 415 V | | 440 V | | 500 V | | 660 V 690 V |
---|
P | | I | | I | | I | | I | | I |
---|
kW | | A | | A | | A | | A | | A |
---|
| | | | | | | | | | |
---|
0.18 | | 1.04 | | - | | - | | - | | - | 0.25 | | 1.4 | | - | | - | | - | | - | 0.37 | | 2 | | 1.1 | | 1.02 | | - | | - | 0.55 | | 2.7 | | 1.5 | | 1.39 | | 1.2 | | - | 0.75 | | 3.2 | | 1.9 | | 1.68 | | 1.5 | | 1.1 | 1.1 | | - | | 2.6 | | 2.41 | | 2.1 | | 1.5 | 1.5 | | - | | 3.6 | | 3.28 | | 2.9 | | 2.1 | 2.2 | | - | | - | | - | | 4 | | 2.9 | 3 | | - | | - | | - | | - | | 3.8 |
|
Ambient temperature >Open |
|
Ambient temperature >Enclosed |
IEC/EN 60947, VDE 0660,UL, CSA |
Mounting position |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Direction of incoming supply |
- 40 - 80 °C |
Degree of protection >Device |
-25 - +55 °C |
Degree of protection >Terminations |
- 25 - 40 °C |
Protection against direct contact when actuated from front (EN 50274) |
|
Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 |
as required |
Altitude |
IP20 |
Rated impulse withstand voltage [Uimp] |
IP00 |
Overvoltage category/pollution degree |
Finger and back-of-hand proof |
Rated operational voltage [Ue
] |
25 g |
Rated uninterrupted current = rated operational current [Iu = Ie
] |
Max. 2000 m |
Rated frequency [f] |
|
Max. operating frequency |
6000 V AC |
Motor switching capacity >AC-3 (up to 690V) |
III/3 |
AC-4 cycle operation >Minimum current flow times |
690 V AC |
AC-4 cycle operation >Minimum cut-out periods |
4 A |
AC-4 cycle operation >Note |
40 - 60 Hz |
Temperature compensation >to IEC/EN 60947, VDE 0660 |
60 Ops/h |
Temperature compensation >Operating range |
4 A |
Setting range of overload releases |
500 (Class 5) 700 (Class 10) 900 (Class 15) 1000 (Class 20) ms |
short-circuit release |
500 ms |
Short-circuit release tolerance |
In AC-4 cycle operation, going below the minimum current flow time can cause overheating of the load (motor). For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. ms |
Phase-failure sensitivity |
|
Rated operational current for specified heat dissipation [In] |
- 5…40 °C |
Heat dissipation per pole, current-dependent [Pvid] |
- 25…55 °C |
Equipment heat dissipation, current-dependent [Pvid] |
0.25 - 1 x Iu
|
Static heat dissipation, non-current-dependent [Pvs] |
Trip block, fixed: 15.5 x Ir delayed approx. 60 ms |
Heat dissipation capacity [Pdiss] |
± 20% |
Operating ambient temperature min. |
IEC/EN 60947-4-1, VDE 0660 Part 102 |
Operating ambient temperature max. |
|
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
4 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0.2 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0.6 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-25 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+55 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
|
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Overload release current setting |
Is the panel builder´s responsibility. |
Initial value of the undelayed short-circuit release - setting range |
Is the panel builder´s responsibility. |
End value adjustment range undelayed short-circuit release |
Is the panel builder´s responsibility. |
Rated permanent current Iu |
Is the panel builder´s responsibility. |
Voltage type for actuating |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated control supply voltage Us at AC 50HZ |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated control supply voltage Us at AC 60HZ |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated control supply voltage Us at DC |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of poles |
|
Short-circuit release function |
|
With ground fault protection function |
1 - 4 A |
Type of motor protection |
15.5 A |
Product Standards |
62 A |
UL File No. |
4 A |
UL Category Control No. |
Self powered |
CSA File No. |
0 - 0 V |
CSA Class No. |
0 - 0 V |
North America Certification |
0 - 0 V |
Specially designed for North America |
3 |
Characteristic curve |
Delayed |