alt
alt

NZMH2-A20-BT
110296 NZMH2-A20-BT
110296

Devre kesici, 3p, 20A, kutu terminalleri Devre kesici NZM2, 3 kutuplu, Anahtarlama kapasitesi 400/415 V 50 Hz( Icu ): 150 kA, Nominal akım = nominal kesintisiz akım Nominal akım = nominal kesintisiz akım( In = Iu ): 20 A, Montaj tipi: Sabit, Kutu terminal, Standart/Onay: IEC, Koruma fonksiyonu: Sistem ve kablo koruması

Devre kesici, 3p, 20A, kutu terminalleri
Devre kesici NZM2, 3 kutuplu, Anahtarlama kapasitesi 400/415 V 50 Hz( Icu ): 150 kA, Nominal akım = nominal kesintisiz akım Nominal akım = nominal kesintisiz akım( In = Iu ): 20 A, Montaj tipi: Sabit, Kutu terminal, Standart/Onay: IEC, Koruma fonksiyonu: Sistem ve kablo koruması

Product range Circuit-breaker
Protective function System and cable protection
Standard/Approval IEC
Installation type Fixed
Release system Thermomagnetic release
Construction size NZM2
Number of poles 3 pole
Standard equipment Box terminal
400/415 V 50 Hz [Icu ] 150 kA
Rated current = rated uninterrupted current [In = Iu] 20 A
Overload trip [Ir ]
15 - 20 A
Short-circuit releases [Irm ]
>Non-delayed [Ii = In x …]
15 - 20 A
Short-circuit releases [Irm ]
>min.
350 A fixed
Standards 350 A
Protection against direct contact IEC/EN 60947
Climatic proofing Finger and back of hand proof to VDE 0106 Part 100
Ambient temperature
>Ambient temperature, storage
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Operation
- 40 - + 70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 -25 - +70 °C
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140
>between the auxiliary contacts
500 V AC
Weight 300 V AC
Mounting position 2.345 kg
Direction of incoming supply
Vertical and 90° in all directions
  With XFI earth-fault release:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in unit
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90° right/left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Degree of protection
>Device
as required
Degree of protection
>Enclosures
In the operating controls area: IP20 (basic degree of protection)
Degree of protection
>Terminations
With insulating surround: IP40
With door coupling rotary handle: IP66
Other technical data (sheet catalogue) Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Rated current = rated uninterrupted current [In = Iu] Temperature dependency, Derating
Rated surge voltage invariability [Uimp ]
>Main contacts
20 A
Rated surge voltage invariability [Uimp ]
>Auxiliary contacts
8000 V
Rated operational voltage [Ue] 6000 V
Rated operational voltage [Ue] 690 V AC
Overvoltage category/pollution degree 750 V DC
Rated insulation voltage [Ui ]

The following settings are required in order to ensure correct tripping:

The fast-response release will take longer to respond when used for DC applications. Because of this, the setting on the trip block inscription, which is specified for AC currents, must be set to a lower value for DC currents.

DC correction factor for instantaneous release response value:

o NZM1: 1.25

o NZM2: 1.35

o NZM3: 1.45

Example: NZM3 Ie = 500A. Desired DC tripping current: 10 * Ie = 5000A.

Calculation:

• Desired DC value / correction factor = AC setting on trip block

• 5000A / 1.45 = 3448 A ~ 7 * Ie = Value that needs to be set on the trip block

Permitted circuit configurations:

    
Use in unearthed supply systems III/3
Rated short-circuit making capacity [Icm ]
>240 V [Icm ]
1000 V
Rated short-circuit making capacity [Icm ]
>400/415 V [Icm ]
≦ 690 V
Rated short-circuit making capacity [Icm ]
>440 V 50/60 Hz [Icm ]
330 kA
Rated short-circuit making capacity [Icm ]
>525 V 50/60 Hz [Icm ]
330 kA
Rated short-circuit making capacity [Icm ]
>690 V 50/60 H [Ic]
286 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>240 V 50/60 Hz [Icu ]
105 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>400/415 V 50/60 Hz [Icu ]
40 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>440 V 50/60 Hz [Icu ]
150 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>525 V 50/60 Hz [Icu ]
150 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>690 V 50/60 Hz [Icu ]
130 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>500 V DC [Icu]
50 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>750 V DC [Icu]
20 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>240 V 50/60 Hz [Ics ]
60 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>400/415 V 50/60 Hz [Ics ]
60 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>440 V 50/60 Hz [Ics ]
150 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>525 V 50/60 Hz [Ics ]
150 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>690 V 50/60 Hz [Ics]
130 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>500 V DC [Ics]
37.5 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>750 V DC [Ics]
5 kA
Rated short-circuit breaking capacity Icn [Icn ] 15 kA
Rated short-time withstand current
>t = 0.3 s [Icw ]
15 kA
Rated short-time withstand current
>t = 1 s [Icw ]
Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Utilization category to IEC/EN 60947-2 1.9 kA
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) [Operations] 85 kA
Lifespan, electrical
>AC-1
>400 V 50/60 Hz [Operations]
A
Lifespan, electrical
>AC-1
>415 V 50/60 Hz [Operations]
20000
Lifespan, electrical
>AC-1
>690 V 50/60 Hz [Operations]
10000
Lifespan, electrical
>AC--3
>400 V 50/60 Hz [Operations]
10000
Lifespan, electrical
>AC--3
>415 V 50/60 Hz [Operations]
7500
Lifespan, electrical
>AC--3
>690 V 50/60 Hz [Operations]
6500
Lifespan, electrical
>DC-1
>500 V DC [Operations]
6500
Lifespan, electrical
>DC-1
>750 V DC [Operations]
5000
Lifespan, electrical
>DC - 3
>500 V DC [Operations]
7500
Lifespan, electrical
>DC - 3
>750 V DC [Operations]
7500
Lifespan, electrical
>Max. operating frequency
3000
Total break time at short-circuit 3000
Standard equipment 120 Ops/h
Optional accessories < 10 ms
Round copper conductor
>Box terminal
>Solid
Box terminal
Round copper conductor
>Box terminal
>Stranded
Screw terminal
Tunnel terminal
connection on rear
Round copper conductor
>Tunnel terminal
>Solid
1 x (10 - 16)
2 x (6 - 16) mm2
Round copper conductor
>Tunnel terminal
>Stranded
>1-hole
1 x (25 - 185)
2 x (25 - 70) mm2
Round copper conductor
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1 x 16 mm2
Round copper conductor
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x (25 - 185) mm2
Al circular conductor
>Tunnel terminal
>Solid
1 x (10 - 16)
2 x (6 - 16) mm2
Al circular conductor
>Tunnel terminal
>Stranded
>Stranded
1 x (25 - 185)
2 x (25 - 70) mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [min.]
1 x 16 mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [max.]
1 x (25 - 185) mm2
Cu strip (number of segments x width x segment thickness)
>Bolt terminal and rear-side connection
>Flat copper strip, with holes [min.]
2 x 9 x 0.8 mm
Cu strip (number of segments x width x segment thickness)
>Bolt terminal and rear-side connection
>Flat copper strip, with holes [max.]
10 x 16 x 0.8
(2x) 8 x 15.5 x 0,8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Screw connection
2 x 16 x 0.8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [min.]
10 x 24 x 0.8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [max.]
M8
Control cables 16 x 5 mm
Rated operational current for specified heat dissipation [In] 24 x 8 mm
Equipment heat dissipation, current-dependent [Pvid] 1 x (0.75 - 2.5)
2 x (0.75 - 1.5) mm2
Operating ambient temperature min. 20 A
Operating ambient temperature max. 5.1 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+70 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated permanent current Iu Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 20 A
Overload release current setting 690 - 690 V
Adjustment range short-term delayed short-circuit release 150 kA
Adjustment range undelayed short-circuit release 15 - 20 A
Integrated earth fault protection 0 - 0 A
Type of electrical connection of main circuit 350 - 350 A
Device construction No
Suitable for DIN rail (top hat rail) mounting Frame clamp
DIN rail (top hat rail) mounting optional Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact No
Number of auxiliary contacts as normally open contact Yes
Number of auxiliary contacts as change-over contact 0
With switched-off indicator 0
With under voltage release 0
Number of poles No
Position of connection for main current circuit No
Type of control element 3
Complete device with protection unit Front side
Motor drive integrated Rocker lever
Motor drive optional Yes
Degree of protection (IP) No
Characteristic curve Yes
Characteristic curve IP20
Characteristic curve 123U176

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

NZMH2-4-VX250/VAR
Eaton
NZMH2-VX250-SVE
Eaton
NZMS2-4-VX250/VAR
Eaton
NZMS2-4-VX160
Eaton
NZMS2-MX220-SVE
Eaton
NZMS2-VX250-SVE
Eaton
NZMN2-4-VX160/VAR
Eaton
NZMN2-VX100-BT
Eaton