alt
alt

M22-SWD-K22LEDC-W
116009 M22-SWD-K22LEDC-W
116009

Fonksiyon elemanı, RMQ-Titan çalıştırma elemanları M22-... ile kombinasyon için, 2 enversör kontak, Tabana sabitleme, beyaz Fonksiyon elemanı, Sabitleme: Tabana sabitleme, SmartWire-DT'ye bağlantı: evet

Fonksiyon elemanı, RMQ-Titan çalıştırma elemanları M22-... ile kombinasyon için, 2 enversör kontak, Tabana sabitleme, beyaz
Fonksiyon elemanı, Sabitleme: Tabana sabitleme, SmartWire-DT'ye bağlantı: evet

Basic function accessories Function elements
Function for combination with RMQ-Titan operating elements M22-...
Contacts 2 changeover contact
Fixing Base fixing
Contact sequence 2723SWI-5
Contact travel diagram
stroke in connection with front element
116U024
Configuration 116Q015
Connection to SmartWire-DT white
Standards 116C063
Dimensions (W x H x D) yes
Weight IEC/EN 61131-2
EN 50178
Mounting position 17 x 45 x 42 mm
Protection type (IEC/EN 60529, EN50178, VBG 4) 14 g
Vibrations (IEC/EN 61131-2:2008)
>Constant amplitude 3,5 mm
As required
Vibrations (IEC/EN 61131-2:2008)
>Constant acceleration 1 g
IP20
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms 5 - 8.4 Hz
Drop to IEC/EN 60068-2-31 [Drop height] 8.4 - 150 Hz
Free fall, packaged (IEC/EN 60068-2-32) 9 Impacts
Overvoltage category 50 mm
Pollution degree 0.3 m
Electrostatic discharge (IEC/EN 61131-2:2008)
>Air discharge (Level 3)
Not applicable
Electrostatic discharge (IEC/EN 61131-2:2008)
>Contact discharge (Level 2)
2
Electromagnetic fields (IEC/EN 61131-2:2008)
>80 - 1000 MHz
8 kV
Electromagnetic fields (IEC/EN 61131-2:2008)
>1.4 - 2 GHz
4 kV
Electromagnetic fields (IEC/EN 61131-2:2008)
>2 - 2.7 GHz
10 V/m
Radio interference suppression (SmartWire-DT) 3 V/m
Burst (IEC/EN 61131-2:2008, Level 3)
>Supply cable
1 V/m
Burst (IEC/EN 61131-2:2008, Level 3)
>SmartWire-DT cable
EN 55011 Class A
Radiated RFI (IEC/EN 61131-2:2008, Level 3) 2 kV
Ambient temperature
>Operating ambient temperature (IEC 60068-2)
1 kV
Ambient temperature
>Storage
10 V
Relative humidity
>Condensation
-30 - +55 °C
Relative humidity
>Relative humidity, non-condensing (IEC/EN 60068-2-30)
- 40 - + 80 °C
Station type Take appropriate measures to prevent condensation
Address allocation 5 - 95 %
Status indication SmartWire-DT slave
Connections automatic
Plug connectors Green LED
Baud rate setting Plug, 8-pole
Switching state display M22-SWD-I…LP
Diagnostics automatic
Fixing Yes LED
Rated operational current for specified heat dissipation [In] Yes
Heat dissipation per pole, current-dependent [Pvid] Base fixing
Equipment heat dissipation, current-dependent [Pvid] 0 A
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0.3 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-30 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+55 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of contacts as change-over contact Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of contacts as normally open contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of contacts as normally closed contact 0
Number of fault-signal switches 2
Rated operation current Ie at AC-15, 230 V 2
Type of electric connection 0
Model 0 A
Mounting method Flat plug-in connection
Lamp holder Top mounting
UL File No. Front fastening
UL Category Control No. LED not exchangeable
CSA File No. E29184
CSA Class No. NKCR
North America Certification 2324643
Specially designed for North America 3211-07

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

DS7-34DSX200N0-D
Eaton
DS7-34DSX160N0-D
Eaton
DS7-34DSX135N0-D
Eaton
DS7-34DSX081N0-D
Eaton
NZM-XSWD-704
Eaton
DS7-34DSX100N0-D
Eaton
DS7-34DSX032N0-D
Eaton