Product range |
RMQ-Titan |
Basic function |
Housing Controlled stop pushbuttons/emergency-stop buttons |
Single unit/Complete unit |
Complete unit |
Design |
Mushroom-shaped |
Diameter [⌀] |
38 mm |
Illumination |
Non-illuminated |
Approval |
|
Connection type |
Pull-to-release function |
Description |
Screw connection |
Mushroom head |
Tamper-proof according to ISO 13850/EN 418 |
Enclosure covers |
Red |
Degree of Protection |
|
Connection to SmartWire-DT |
Yellow |
N/C = Normally closed |
IP66, IP69 |
Notes |
no |
[mm] |
3 NC |
Maximum travel [mm] |
= safety function, by positive opening to IEC/EN 60947-5-1 |
Minimum force for positive opening [ N] |
4.8 |
Front dimensions |
5.7 |
Standards |
30 |
Lifespan, mechanical [Operations] |
35 |
Operating frequency [Operations/h] |
IEC/EN 60947 VDE 0660 |
Actuating force |
> 0.1 x 106 |
Climatic proofing |
≦ 600 |
Degree of Protection |
≦ 50 n |
Ambient temperature >Open |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mounting position |
IP66, IP69 |
Mechanical shock resistance |
-25 - +70 °C |
shipping classification |
As required |
Rated conditional short-circuit current [Iq] |
50 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 g |
Rated operational current for specified heat dissipation [In] |
DNV GL LR |
Heat dissipation per pole, current-dependent [Pvid] |
|
Equipment heat dissipation, current-dependent [Pvid] |
1 kA |
Static heat dissipation, non-current-dependent [Pvs] |
6 A |
Heat dissipation capacity [Pdiss] |
0.11 W |
Operating ambient temperature min. |
0 W |
Operating ambient temperature max. |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
-25 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
+70 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Please enquire |
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances |
Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
Colour button |
Is the panel builder´s responsibility. |
Construction type lens |
Is the panel builder´s responsibility. |
Diameter cap |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Hole diameter |
Red |
Width opening |
Round |
Height opening |
38 mm |
Degree of protection (IP) |
22.5 mm |
Degree of protection (NEMA) |
0 mm |
Type of button |
0 mm |
Suitable for illumination |
IP66 |
Switching function latching |
4X |
Spring-return |
Flat |
With front ring |
No |
Material front ring |
Yes |
Colour front ring |
No |
Suitable for emergency stop |
No |
Unlocking method |
Plastic |
Product Standards |
Other |
UL File No. |
Yes |
UL Category Control No. |
Pull-release |
CSA File No. |
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking |
CSA Class No. |
E29184 |
North America Certification |
NKCR |
Degree of Protection |
012528 |