Product range |
RMQ-Titan |
Basic function |
Pushbutton actuators |
Single unit/Complete unit |
Single unit |
Design |
Flat |
button plate |
momentary |
Button plate |
red |
Degree of Protection |
|
Front ring |
inscribed |
Connection to SmartWire-DT |
IP66, IP67, IP69 |
Front dimensions |
Bezel: titanium |
Standards |
yes with SWD-RMQ connections |
Lifespan, mechanical [Operations] |
22 x 22 |
Operating frequency [Operations/h] |
IEC/EN 60947 VDE 0660 |
Actuating force |
> 5 x 106 |
Climatic proofing |
≦ 3600 |
Degree of Protection |
≦ 5 n |
Ambient temperature >Open |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Storage |
IP66, IP67, IP69 |
Mounting position |
-25 - +70 °C |
Mechanical shock resistance |
- 40 - + 80 °C |
shipping classification |
As required |
Rated operational current for specified heat dissipation [In] |
30 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 g |
Heat dissipation per pole, current-dependent [Pvid] |
DNV GL LR |
Equipment heat dissipation, current-dependent [Pvid] |
|
Static heat dissipation, non-current-dependent [Pvs] |
Indoor and protected outdoor installation |
Heat dissipation capacity [Pdiss] |
0 A |
Operating ambient temperature min. |
0 W |
Operating ambient temperature max. |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
-25 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
+70 °C |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Please enquire |
10.4 Clearances and creepage distances |
Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Colour button |
Not applicable. |
Number of command positions |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Construction type lens |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Hole diameter |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Width opening |
Red |
Height opening |
1 |
Type of button |
Round |
Suitable for illumination |
22 mm |
With protective cover |
0 mm |
Labelled |
0 mm |
Switching function latching |
Flat |
Spring-return |
No |
With front ring |
No |
Material front ring |
Yes |
Colour front ring |
No |
Degree of protection (IP), front side |
Yes |
Degree of protection (NEMA), front side |
Yes |
Product Standards |
Plastic |
UL File No. |
Chrome |
UL Category Control No. |
IP67/IP69K |
CSA File No. |
4X |
CSA Class No. |
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking |
North America Certification |
E29184 |
Degree of Protection |
NKCR |