Product range |
RMQ-Titan |
Basic function |
Pushbutton actuators Pushbutton actuators |
Single unit/Complete unit |
Complete unit |
Design |
Enclosure |
Connection type |
momentary |
Number of locations |
Screw connection |
Enclosure covers |
1 Qty. |
RAL Value |
Grey |
button plate |
RAL 7035 |
Button plate |
light grey, RAL 7035 |
Degree of Protection |
green |
Front ring |
|
Connection to SmartWire-DT |
inscribed |
N/C = Normally closed |
IP66, IP67, IP69 |
N/O = Normally open |
Bezel: titanium |
Notes |
no |
[mm] |
1 NC |
Maximum travel [mm] |
1 N/O |
Minimum force for positive opening [ N] |
= safety function, by positive opening to IEC/EN 60947-5-1 |
Contact sequence |
4.8 |
Front dimensions |
5.7 |
Standards |
20 |
Lifespan, mechanical [Operations] |
|
Operating frequency [Operations/h] |
22 x 22 |
Actuating force |
IEC/EN 60947 VDE 0660 |
Climatic proofing |
> 1 x 106 |
Degree of Protection |
≦ 1800 |
Ambient temperature >Open |
≦ 5 n |
Mounting position |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance |
IP66, IP67, IP69 |
Cable entry knockouts >Base |
-25 - +70 °C |
Cable entry knockouts >Sides |
As required |
shipping classification |
30 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 g |
Rated conditional short-circuit current [Iq] |
2 x 16 Quantity x M… |
Rated operational current for specified heat dissipation [In] |
1 x 20 2 x 25/20 Quantity x M… |
Heat dissipation per pole, current-dependent [Pvid] |
DNV GL LR |
Equipment heat dissipation, current-dependent [Pvid] |
|
Static heat dissipation, non-current-dependent [Pvs] |
1 kA |
Heat dissipation capacity [Pdiss] |
6 A |
Operating ambient temperature min. |
0.11 W |
Operating ambient temperature max. |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
-25 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
+70 °C |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Please enquire |
10.4 Clearances and creepage distances |
Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Number of command positions |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Number of push buttons |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of indicator lights |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of key switches |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of selector switches |
1 |
Number of mushroom-shaped push-buttons |
1 |
Suitable for emergency stop |
0 |
Rated control supply voltage Us at AC 50HZ |
0 |
Rated control supply voltage Us at AC 60HZ |
0 |
Rated control supply voltage Us at DC |
0 |
Colour housing cover |
No |
Material housing |
115 - 500 V |
Number of contacts as normally open contact |
115 - 500 V |
Number of contacts as normally closed contact |
24 - 220 V |
Number of contacts as change-over contact |
Grey |
Degree of protection (IP) |
Plastic |
Degree of protection (NEMA) |
1 |
Product Standards |
1 |
UL Category Control No. |
0 |
CSA File No. |
IP67/IP69K |
CSA Class No. |
4X |
North America Certification |
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking |
Degree of Protection |
NKCR |