Kaçak akım devre kesici (RCCB), 125A, 4p, 30mA, AC tipi Kaçak akım devre kesici, 4 kutuplu, Nominal akım In:, Nominal kısa devre gücü Icn: 10, yedek sigorta ile kA, Nominal arıza akımı IΔN: 0,03 A
Kaçak akım devre kesici (RCCB), 125A, 4p, 30mA, AC tipi
Kaçak akım devre kesici, 4 kutuplu, Nominal akım In:, Nominal kısa devre gücü Icn: 10, yedek sigorta ile kA, Nominal arıza akımı IΔN: 0,03 A
Basic function | Residual current circuit-breakers |
Number of poles | 4 pole |
Application | Switchgear for industrial and advanced commercial applications |
Rated current [In] | 125 A |
Rated short-circuit strength [Icn] | 10 with back-up fuse kA |
Rated fault current [IΔN] | 0.03 A |
Type | Type AC |
Tripping | non-delayed s… |
Product range | FRCmM-125 |
Sensitivity | AC current sensitive |
Impulse withstand current | Partly surge-proof 250 A |
Types conform to | IEC/EN 61008 |
Current test marks | As per inscription |
Tripping | non-delayed s… |
Rated voltage according to IEC/EN 60947-2 [Un] | 240/415 V AC |
Rated frequency [f] | 50 Hz |
Limit values of the operating voltage >Test circuit |
184 - 440 V AC |
Rated fault current [IΔn] | 30 mA |
Sensitivity | AC current sensitive |
Rated insulation voltage [Ui ] | 440 V |
Rated impulse withstand voltage [Uimp] | 4 (1.2/50μs) kV |
Rated short-circuit strength [Icn] | 10 with back-up fuse kA |
Impulse withstand current | 250 A (8/20 μs) surge-proof |
Max. admissible back-up fuse >Short-circuit [gG/gL] |
125 A |
Max. admissible back-up fuse >Overload [gG/gL] |
80 A |
Rated making and breaking capacity / Rated residual making and breaking capacity [Im / IΔm] | 1250 A |
lifespan >Electrical [Operations] |
≧ 4000 |
lifespan >Mechanical [Operations] |
≧ 20000 |
Standard front dimension | 45 mm |
Device height | 80 mm |
Built-in width | 70 (4TE) mm |
Mounting | Quick attachment for DIN-rail EN 50022 |
Degree of Protection | IP40, IP54 (with moisture-proof enclosure) |
Terminals top and bottom | Twin-purpose terminals |
Terminal protection | Busbar tag shroud to BGV A3, ÖVE-EN 6 |
Terminal cross-section >Solid |
1.5 - 50 2 x (1.5 - 16) mm2 |
Terminal cross-section >Stranded |
1.5 - 50 2 x (1.5 - 16) mm2 |
Thickness of busbar material | 0.8 - 2 mm |
Climatic proofing | 25-55°C/90-95% relative humidity according to IEC 60068-2 |
Mounting position | As required |
Contact position indicator | red / green |
Trip indication | toggle-center postition |
Rated operational current for specified heat dissipation [In] | 125 A |
Heat dissipation per pole, current-dependent [Pvid] | 0 W |
Equipment heat dissipation, current-dependent [Pvid] | 22.5 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +60 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Starting at 40 °C, the max. permissible continuous current decreases by 2.2% for every 1 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of poles | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated voltage | 4 |
Rated current | 240 V |
Rated fault current | 125 A |
Rated insulation voltage Ui | 30 mA |
Rated impulse withstand voltage Uimp | 440 V |
Mounting method | 4 kV |
Leakage current type | DIN rail |
Selective protection | AC |
Short-time delayed tripping | No |
Short-circuit breaking capacity (Icw) | No |
Surge current capacity | 10 kA |
Frequency | 0.25 kA |
Additional equipment possible | 50 Hz |
With interlocking device | Yes |
Degree of protection (IP) | Yes |
Width in number of modular spacings | IP20 |
Built-in depth | 4 |
Ambient temperature during operating | 77.5 mm |
Pollution degree | -25 - 40 °C |
Connectable conductor cross section multi-wired | 2 |
Connectable conductor cross section solid-core | 1.5 - 16 mm² |
Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.