G/Ç genişletme, entegre, 24 V DC, 6DI, 4DO(T) CANopen aracılığıyla G/Ç genişletme. XC100/200, EC4P, XV-… için kullanılabilir
G/Ç genişletme, entegre, 24 V DC, 6DI, 4DO(T)
CANopen aracılığıyla G/Ç genişletme. XC100/200, EC4P, XV-… için kullanılabilir
Product range | Remote I/O systems Compact PLCs |
Subrange | I/O expansions digital/analog |
Basic function | Expansions |
Description | usable via CANopen® |
Function | CANopen® expansion EC4E |
Inputs expansion (number) | |
Transistor | Digital: 6 |
Real time clock | |
Supply voltage | 4 |
For use with | |
For use with | ✔ |
Dimensions (W x H x D) | 24 V DC |
Weight | easy800 EC4P MFD-CP8… MFD-CP10... |
Mounting | XC100/200, EC4P, MFD4 (via CANopen®) |
Solid | |
Flexible with ferrule | 71.5 x 90 x 58 (4 PE) mm |
Standard screwdriver | 0.2 kg |
Max. tightening torque | Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Operating ambient temperature | |
Condensation | 0.2/4 (AWG 22 - 12) mm2 |
Storage [ϑ] | 0.2/2.5 (AWG 22 - 12) mm2 |
Mounting position | 0.8 x 3.5 mm |
Overvoltage category/pollution degree | 0.6 Nm |
Electrostatic discharge (ESD) >applied standard |
|
Electrostatic discharge (ESD) >Air discharge |
-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 | Take appropriate measures to prevent condensation |
Burst | -40 - +70 °C |
power pulses (Surge) | |
Immunity to line-conducted interference to (IEC/EN 61000-4-6) | Vertical or horizontal |
Clearance in air and creepage distances | |
Insulation resistance | II/2 |
Rated operational voltage [Ue] | IEC EN 61000-4-2, Level 3 |
Permissible range [Ue] | 8 kV |
Residual ripple | 10 V/m |
Input current | according to IEC/EN 61000-4-4 kV |
Voltage dips | 2 kV (supply cables, symmetrical, EASY...AC) 0.5 kV (supply cables, symmetrical, easy-DC) according to IEC/EN 61000-4-5 |
Heat dissipation [P] | 10 V |
CANopen® >Data transfer rate |
|
CANopen® >Bus termination (first and last station) |
EN 50178, UL 508, CSA C22.2, No. 142 |
CANopen® >Connection types |
EN 50178 |
Mode slave >Stations |
|
Mode slave >PDO type |
24 DC (-15/+20%) V |
Mode slave >Control contact rated current |
20.4 - 28.8 V DC |
Number | ≦ 5 % |
Potential isolation | 150 mA at Ue at no load |
Rated operational voltage [Ue] | ≤ 20 (IEC/EN 61131-2) ms |
Input voltage | Normally 3.5 W |
Input current on 1 signal >Input current at signal 1 |
|
Deceleration time | 500 kBit/s, 25 m250 kBit/s, 40m125 kBit/s, 125 m50 kBit/s, 300 m20 kBit/s, 700 m10 kBit/s, 1000 m |
Cable length | Via integrated Dip switch |
Number | 2 x terminals (see terminal capacity) |
Rated operational voltage [Ue] | max. 62 Number |
Permissible range [Ue] | Asynchronous, cyclic, acyclic |
Residual ripple | to DS301V4 |
Supply current | |
Protection against polarity reversal | 6 |
Potential isolation | from the outputs: yes |
Rated operational current at signal „1” DC per channel [Ie] | 24 V DC |
Lamp load without Rv per channel | < 5 (R1 - R6) at signal "0" > 15 (R1 - R6) at signal "1" V DC |
Residual current on 0 signal per channel | 3.3 (R1 to R6 (R12)) mA |
Max. output voltage | 20 (from “0” to “1”, debounce ON) Normally 0.25 (R1 - R12) (from “0” to “1”, debounce OFF) 20 (from „1“ to „0“) ms |
Short-circuit protection | 100 (unshielded) m |
Short-circuit tripping current for Ra ≦ 10 mΩ | |
Total short-circuit current | 4 |
Peak short-circuit current | 24 V DC |
Thermal cutout | 20.4 - 28.8 V DC |
Max. operating frequency with constant resistive load | 5 % |
Parallel connection of outputs >With resistive load, inductive load with external suppressor circuit, combination within a group |
Norm./max. 9/16 at signal 0 12/22 at signal 1 mA |
Parallel connection of outputs >Number of outputs [max.] |
yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.) |
Parallel connection of outputs >Max. total current |
from power supply, inputs to the memory card: yes |
Protection against polarity reversal | Max. 0.5 A |
Bus termination (first and last station) | 5 W |
Rated operational current for specified heat dissipation [In] | < 0.1 mA |
Heat dissipation per pole, current-dependent [Pvid] | 2.5 (signal 0 at external load < 10 MΩ) U = Ue - 1 V (signal 1 at Ie = 0.5 A) V |
Equipment heat dissipation, current-dependent [Pvid] | Yes, thermal (analysis via diagnostics input I16, I15; R15, R16) |
Static heat dissipation, non-current-dependent [Pvs] | 0.7 ≦ Ie ≦ 2 per output A |
Heat dissipation capacity [Pdiss] | 8 A |
Operating ambient temperature min. | 16 A |
Operating ambient temperature max. | Yes |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
40000 Operations/h |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Group 1: Q1 to Q4 |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
4 |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
2 (Caution! Outputs must be actuated simultaneously and for the same length of time.) A |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
|
10.2 Strength of materials and parts >10.2.5 Lifting |
yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.) |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
|
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Via integrated Dip switch |
10.3 Degree of protection of ASSEMBLIES | |
10.4 Clearances and creepage distances | 0 A |
10.5 Protection against electric shock | 0 W |
10.6 Incorporation of switching devices and components | 0 W |
10.7 Internal electrical circuits and connections | 3.4 W |
10.8 Connections for external conductors | 0 W |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
-25 °C |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
+55 °C |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
|
10.10 Temperature rise | Meets the product standard´s requirements. |
10.11 Short-circuit rating | Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility | Meets the product standard´s requirements. |
10.13 Mechanical function | Meets the product standard´s requirements. |
Supply voltage AC 50 Hz | Meets the product standard´s requirements. |
Supply voltage AC 60 Hz | Does not apply, since the entire switchgear needs to be evaluated. |
Supply voltage DC | Does not apply, since the entire switchgear needs to be evaluated. |
Voltage type of supply voltage | Meets the product standard´s requirements. |
Number of digital inputs | Meets the product standard´s requirements. |
Number of digital outputs | Meets the product standard´s requirements. |
Digital inputs configurable | Does not apply, since the entire switchgear needs to be evaluated. |
Digital outputs configurable | Does not apply, since the entire switchgear needs to be evaluated. |
Input current at signal 1 | Is the panel builder´s responsibility. |
Permitted voltage at input | Is the panel builder´s responsibility. |
Type of voltage (input voltage) | Is the panel builder´s responsibility. |
Type of digital output | Is the panel builder´s responsibility. |
Output current | Is the panel builder´s responsibility. |
Permitted voltage at output | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Type of output voltage | Is the panel builder´s responsibility. |
Short-circuit protection, outputs available | Is the panel builder´s responsibility. |
Redundancy | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Type of electric connection | |
Time delay at signal exchange | |
Suitable for safety functions | 0 - 0 V |
Category according to EN 954-1 | 0 - 0 V |
SIL according to IEC 61508 | 20.4 - 28.8 V |
Performance level acc. EN ISO 13849-1 | DC |
Appendant operation agent (Ex ia) | 6 |
Appendant operation agent (Ex ib) | 4 |
Explosion safety category for gas | No |
Explosion safety category for dust | No |
Width | 3.3 mA |
Height | 0 - 0 V |
Depth | DC |
North America Certification | Transistor |
Specially designed for North America | 0.5 A |
Current Limiting Circuit-Breaker | 0 - 0 V |
Degree of Protection | DC |
Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.