DX-EMC34-042
184503 DX-EMC34-042
184503

Radyo parazitini bastırma filtresi, üç fazlı, ULN= maks. 520 + %10 V, 42 A, Şunlarla kullanım için: DC1, DA1, DG1 Radyo parazitini önleme filtresi, Açıklama: üç fazlı, Şebeke voltajı (50/60Hz): ULN= maks. 520 + 10% V, Nominal çalışma akımı: Ie= 42 A, Kullanım için: DC1, DA1, DG1, Koruma Sınıfı: IP20, Bağlantı tipi: Vidalı terminal, PE saplama, Notlar: Ayrı montaj, Standartlar: EN 50178, IEC 61800-3, EN 61800-3 dahil. A11

Radyo parazitini bastırma filtresi, üç fazlı, ULN= maks. 520 + %10 V, 42 A, Şunlarla kullanım için: DC1, DA1, DG1
Radyo parazitini önleme filtresi, Açıklama: üç fazlı, Şebeke voltajı (50/60Hz): ULN= maks. 520 + 10% V, Nominal çalışma akımı: Ie= 42 A, Kullanım için: DC1, DA1, DG1, Koruma Sınıfı: IP20, Bağlantı tipi: Vidalı terminal, PE saplama, Notlar: Ayrı montaj, Standartlar: EN 50178, IEC 61800-3, EN 61800-3 dahil. A11

Description three-phase
Mains voltage (50/60Hz) [ULN] max. 520 + 10% V
Rated operational current [Ie] 42 A
For use with DC1
DA1
DG1
Degree of Protection IP20
Connection type Screw terminal, PE stud
Notes Separate mounting
Standards
Environmental conditions
>Altitude
EN 50178, IEC 61800-3, EN 61800-3 incl. A11
Degree of Protection Up to 2000 m a.s.l.; observe derating at higher altitudes m
Short Circuit Current Rating
>High fault rating
IP20
Rated operational current for specified heat dissipation [In]
Heat dissipation per pole, current-dependent [Pvid] 100 kA
Equipment heat dissipation, current-dependent [Pvid]
Static heat dissipation, non-current-dependent [Pvs] 42 A
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 22 W
Operating ambient temperature max. 0 W
Degree of Protection 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+50 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
IP20
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Type of accessory The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Product Standards Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
UL File No. Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
North America Certification The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

DX-EMC12-014-FS1
Eaton
DX-EMC12-019-FS1
Eaton