alt
alt

DILM7-01(26VDC)
186880 DILM7-01(26VDC)
186880

Kontaktör, 3 kutuplu, 380 V 400 V 3 kW, 1 NC, DC çalışma, Vidalı terminaller

Kontaktör, 3 kutuplu, 380 V 400 V 3 kW, 1 NC, DC çalışma, Vidalı terminaller

Product range Contactors
Application Contactors for Motors
Subrange Contactors up to 170 A, 3 pole
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Number of poles Screw terminals
AC-3
>380 V 400 V [Ie]
3 pole
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
7 A
AC-1
>Conventional free air thermal current, 1 pole
>open [Ith ]
22 A
AC-1
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
18 A
AC-3
>220 V 230 V [P]
50 A
AC-3
>380 V 400 V [P]
45 A
AC-3
>660 V 690 V [P]
AC-4
>220 V 230 V [P]
2.2 kW
AC-4
>380 V 400 V [P]
3 kW
AC-4
>660 V 690 V [P]
3.5 kW
N/C = Normally closed 1 kW
Contact sequence 2.2 kW
Instructions 2.9 kW
Can be combined with auxiliary contact
Voltage AC/DC 1 NC
Connection to SmartWire-DT 210S027
Frame size Contacts to EN 50 012.
Integrated varistor suppressor circuit.
with mirror contact.
Standards DILA-XHI(V)…
Lifespan, mechanical
>DC operated [Operations]
DC operation
Operating frequency, mechanical
>DC operated [Operations/h]
no
Climatic proofing 1
Ambient temperature
>Open
Ambient temperature
>Enclosed
IEC/EN 60947, VDE 0660, UL, CSA
Ambient temperature
>Storage
10 x 106
Mounting position 9000
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Main contacts
>N/O contact
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/O contact
-25 - +60 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/C contact
- 25 - 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Main contacts
>N/O contact
- 40 - 80 °C
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/O contact
210N017
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/C contact
10 g
Degree of Protection 7 g
Protection against direct contact when actuated from front (EN 50274) 5 g
Weight
>DC operated
5.7 g
Screw connector terminals
>Terminal capacity main cable
>Solid
3.4 g
Screw connector terminals
>Terminal capacity main cable
>Flexible with ferrule
3.4 g
Screw connector terminals
>Terminal capacity main cable
IP20
Screw connector terminals
>Terminal capacity main cable
>Solid or stranded
Finger and back-of-hand proof
Screw connector terminals
>Terminal capacity main cable
>Stripping length
0.3 kg
Screw connector terminals
>Terminal capacity main cable
>Terminal screw
1 x (0.75 - 4)
2 x (0.75 - 2.5) mm2
Screw connector terminals
>Terminal capacity main cable
>Tightening torque
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Screw connector terminals
>Terminal capacity main cable
>Tool
>Pozidriv screwdriver
Also without ferrule.
Screw connector terminals
>Terminal capacity main cable
>Tool
>Standard screwdriver
single 18 - 10, double 18 - 14 AWG
Screw connector terminals
>Terminal capacity control circuit cables
>Solid
10 mm
Screw connector terminals
>Terminal capacity control circuit cables
>Flexible with ferrule
M3.5
Screw connector terminals
>Terminal capacity control circuit cables
>Solid or stranded
1.2 Nm
Screw connector terminals
>Terminal capacity control circuit cables
>Stripping length
2 Size
Screw connector terminals
>Terminal capacity control circuit cables
>Terminal screw
0.8 x 5.5
1 x 6 mm
Screw connector terminals
>Terminal capacity control circuit cables
>Tightening torque
1 x (0.75 - 4)
2 x (0.75 - 2.5) mm2
Screw connector terminals
>Terminal capacity control circuit cables
>Tool
>Pozidriv screwdriver
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Screw connector terminals
>Terminal capacity control circuit cables
>Tool
>Standard screwdriver
18 - 14 AWG
Rated impulse withstand voltage [Uimp] 10 mm
Overvoltage category/pollution degree M3.5
Rated insulation voltage [Ui] 1.2 Nm
Rated operational voltage [Ue] 2 Size
Safe isolation to EN 61140
>between coil and contacts
0.8 x 5.5
1 x 6 mm
Safe isolation to EN 61140
>between the contacts
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V] 8000 V AC
Breaking capacity
>220 V 230 V
III/3
Breaking capacity
>380 V 400 V
690 V AC
Breaking capacity
>500 V
690 V AC
Breaking capacity
>660 V 690 V
400 V AC
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “2” coordination
>400 V [gG/gL 500 V]
400 V AC
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “2” coordination
>690 V [gG/gL 690 V]
112 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “1” coordination
>400 V [gG/gL 500 V]
70 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “1” coordination
>690 V [gG/gL 690 V]
70 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
50 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 50 °C [Ith =Ie]
40 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 55 °C [Ith =Ie]
20 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 60 °C [Ith =Ie]
16 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
35 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>open [Ith ]
20 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie]
22 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie]
21 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
21 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie]
20 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440V [Ie]
18 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie]
50 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie]
45 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
7 A
AC-3
>Motor rating [P]
>220 V 230 V [P]
7 A
AC-3
>Motor rating [P]
>240V [P]
7 A
AC-3
>Motor rating [P]
>380 V 400 V [P]
7 A
AC-3
>Motor rating [P]
>415 V [P]
7 A
AC-3
>Motor rating [P]
>440 V [P]
5 A
AC-3
>Motor rating [P]
>500 V [P]
4 A
AC-3
>Motor rating [P]
>660 V 690 V [P]
7 A
AC-4
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie ]
2.2 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie ]
2.2 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie ]
3 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie ]
4 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>440 V [Ie ]
4.5 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie ]
3.5 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie ]
3.5 kW
AC-4
>Motor rating [P]
>220 V 230 V [P]
5 A
AC-4
>Motor rating [P]
>240 V [P]
5 A
AC-4
>Motor rating [P]
>380 V 400 V [P]
5 A
AC-4
>Motor rating [P]
>415 V [P]
5 A
AC-4
>Motor rating [P]
>440 V [P]
5 A
AC-4
>Motor rating [P]
>500 V [P]
4.5 A
AC-4
>Motor rating [P]
>660 V 690 V [P]
4 A
Rated operational current, open
>DC-1
>60 V [Ie ]
1 kW
Rated operational current, open
>DC-1
>110 V [Ie ]
1.5 kW
Rated operational current, open
>DC-1
>220 V [Ie ]
2.2 kW
3 pole, at Ith (60°) 2.3 kW
Current heat loss at Ie to AC-3/400 V 2.4 kW
Impedance per pole 2.5 kW
Voltage tolerance
>DC operated [Pick-up]
2.9 kW
Voltage tolerance
>Notes
Voltage tolerance
>DC operated [Drop-out]
20 A
Voltage tolerance
>Notes
20 A
Power consumption of the coil in a cold state and 1.0 x US
>DC operated [Pick-up]
15 A
Power consumption of the coil in a cold state and 1.0 x US
>DC operated [Sealing]
Duty factor 4.5 W
Changeover time at 100 % US (recommended value)
>Main contacts
>DC operated
>Closing delay
>Closing delay
0.3 W
Changeover time at 100 % US (recommended value)
>Main contacts
>DC operated
>Opening delay
>Opening delay
4.6 mΩ
Changeover time at 100 % US (recommended value)
>Arcing time
Emitted interference 0.8 - 1.1 x Uc
Interference immunity 0.85 - 1.1 only with auxiliary contact module with 3 or more N/C contacts
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
0.15 - 0.6 x Uc
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
at least smoothed two-phase bridge rectifier or three-phase rectifier
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
3 W
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
3 W
Switching capacity
>Maximum motor rating
>Single-phase
>115 V
120 V
100 % DF
Switching capacity
>Maximum motor rating
>Single-phase
>230 V
240 V
31 ms
Switching capacity
>General use
12 ms
Auxiliary contacts
>Pilot Duty
>AC operated
10 ms
Auxiliary contacts
>Pilot Duty
>DC operated
Auxiliary contacts
>General Use
>AC
According to EN 60947-1
Auxiliary contacts
>General Use
>AC
According to EN 60947-1
Auxiliary contacts
>General Use
>DC
Auxiliary contacts
>General Use
>DC
1.5 HP
Short Circuit Current Rating
>Basic Rating
>SCCR
2 HP
Short Circuit Current Rating
>Basic Rating
>max. Fuse
3 HP
Short Circuit Current Rating
>Basic Rating
>max. CB
5 HP
Short Circuit Current Rating
>480 V High Fault
>SCCR (fuse)
0.25 HP
Short Circuit Current Rating
>480 V High Fault
>max. Fuse
1 HP
Short Circuit Current Rating
>480 V High Fault
>SCCR (CB)
20 A
Short Circuit Current Rating
>480 V High Fault
>max. CB
A600
Short Circuit Current Rating
>600 V High Fault
>SCCR (fuse)
P300
Short Circuit Current Rating
>600 V High Fault
>max. Fuse
600 V
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>480V 60Hz 3phase, 277V 60Hz 1phase
10 A
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>600V 60Hz 3phase, 347V 60Hz 1phase
250 V
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>480V 60Hz 3phase, 277V 60Hz 1phase
1 A
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>600V 60Hz 3phase, 347V 60Hz 1phase
5 kA
Special Purpose Ratings
>Resistance Air Heating
>480V 60Hz 3phase, 277V 60Hz 1phase
45 A
Special Purpose Ratings
>Resistance Air Heating
>600V 60Hz 3phase, 347V 60Hz 1phase
60 A
Special Purpose Ratings
>Refrigeration Control (CSA only)
>LRA 480V 60Hz 3phase
30/100 kA
Special Purpose Ratings
>Refrigeration Control (CSA only)
>FLA 480V 60Hz 3phase
25 Class RK5/20 Class J A
Special Purpose Ratings
>Refrigeration Control (CSA only)
>LRA 600V 60Hz 3phase
65 kA
Special Purpose Ratings
>Refrigeration Control (CSA only)
>FLA 600V 60Hz 3phase
16 A
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>LRA 480V 60Hz 3phase
30/100 kA
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>FLA 480V 60Hz 3phase
25 Class RK5/20 Class J A
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
12 A
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
12 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
14 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
14 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
12 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
12 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
60 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
10 A
Rated operational current for specified heat dissipation [In] 60 A
Heat dissipation per pole, current-dependent [Pvid] 10 A
Equipment heat dissipation, current-dependent [Pvid] 42 A
Static heat dissipation, non-current-dependent [Pvs] 7 A
Heat dissipation capacity [Pdiss] 0.75 HP
Operating ambient temperature min. 3.7 A
Operating ambient temperature max. 1.5 HP
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
6 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
2 HP
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
3.4 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
3 HP
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
3.9 A
10.2 Strength of materials and parts
>10.2.5 Lifting
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
7 A
10.2 Strength of materials and parts
>10.2.7 Inscriptions
0.1 W
10.3 Degree of protection of ASSEMBLIES 0 W
10.4 Clearances and creepage distances 3 W
10.5 Protection against electric shock 0 W
10.6 Incorporation of switching devices and components -25 °C
10.7 Internal electrical circuits and connections +60 °C
10.8 Connections for external conductors
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 50HZ Meets the product standard´s requirements.
Rated control supply voltage Us at AC 60HZ Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at DC Meets the product standard´s requirements.
Voltage type for actuating Does not apply, since the entire switchgear needs to be evaluated.
Rated operation current Ie at AC-1, 400 V Does not apply, since the entire switchgear needs to be evaluated.
Rated operation current Ie at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power NEMA Is the panel builder´s responsibility.
Modular version The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of auxiliary contacts as normally open contact Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally closed contact Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Type of electrical connection of main circuit The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of normally closed contacts as main contact
Number of main contacts as normally open contact
Product Standards 0 - 0 V
UL File No. 0 - 0 V
UL Category Control No. 26 - 26 V
CSA File No. DC
CSA Class No. 22 A
North America Certification 7 A
Specially designed for North America 3 kW
Accessories 5 A
Characteristic curve 2.2 kW

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton