Product range |
DILL Lighting contactors |
Application |
Contactors for lighting systems |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
AC-5a >220 V 230 V [Ie
] |
|
AC-5a >380 V 400 V [Ie
] |
20 A |
AC-5b >220 V 230 V [Ie] |
20 A |
AC-5b >380 V 400 V [Ie] |
27 A |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
27 A |
Contact sequence |
45 A |
Actuating voltage |
|
Note |
24 V 50 Hz |
Standards |
Switchgear for lighting systems |
---|
| | | | | | | | | | | | |
---|
| DIL | L12 | L18 | L20 | M7 | M9 | M12 | M17 | M25 | M32 | M40 | M50 | Permissible compensation capacitance | Cmax [mF] | 470 | 470 | 470 | 47 | 80 | 100 | 220 | 330 | 470 | 470 | 500 | | | | | | | | | | | | | | Filament lamp | Ie [A] | 14 | 21 | 27 | 6 | 7.5 | 10 | 14 | 21 | 27 | 33 | 42 | Mercury blended lamps | Ie [A] | 12 | 16 | 23 | 5 | 6.5 | 8.5 | 12 | 16 | 23 | 30 | 38 | Fluorescent lamps, conventional -reactor – starter – connection | Ie [A] | 20 | 26 | 35 | 9 | 10 | 15 | 20 | 26 | 35 | 41 | 45 | Fluorescent lamps, conventional -reactor – starter – connection | Ie [A] | 20 | 26 | 35 | 5.5 | 8 | 13 | 15 | 22.5 | 29 | 36 | 47 | Fluorescent lamps, duo circuit (series compensated) | Ie [A] | 12 | 18 | 20 | 5 | 6.5 | 8.5 | 12 | 17.5 | 22.5 | 28 | 35 | electronic upstream devices and LED lamps | Ie [A] | 12 | 18 | 20 | 3.5 | 6 | 10 | 12 | 17.5 | 20 | 25 | 30 | High-pressure mercury-arc lamps | Ie [A] | 12 | 18 | 20 | 3.5 | 6 | 10 | 12 | 17.5 | 20 | 25 | 30 | Metal-halide lamps | Ie [A] | 12 | 18 | 20 | 3.5 | 6 | 10 | 12 | 17.5 | 20 | 25 | 30 | Low-pressure sodium lamps | Ie [A] | 7.5 | 10 | 12 | 3 | 4 | 6 | 7.5 | 10 | 12 | 15 | 22 | | | | | | | | | | | | | | | DIL | M65 | M80 | M95 | M115 | M150 | M185A | M225A | M250A | M300A | M400A | M500A | Permissible compensation capacitance | Cmax [mF] | 500 | 550 | 620 | 830 | 970 | 2055 | 2300 | 2600 | 3000 | 3250 | 3500 | | | | | | | | | | | | | | Filament lamp | Ie [A] | 55 | 67 | 79 | 95 | 125 | 153 | 187 | 208 | 349 | 332 | 415 | Mercury blended lamps | Ie [A] | 45 | 65 | 67 | 80 | 110 | 123 | 150 | 167 | 200 | 266 | 332 | Fluorescent lamps, conventional -reactor – starter – connection | Ie [A] | 55 | 95 | 100 | 125 | 145 | 207 | 237 | 263 | 300 | 375 | 525 | Fluorescent lamps, conventional -reactor – starter – connection | Ie [A] | 59 | 71 | 95 | 100 | 138 | 186 | 213 | 236 | 270 | 338 | 473 | Fluorescent lamps, duo circuit (series compensated) | Ie [A] | 45.5 | 56 | 66.5 | 80.5 | 105 | 130 | 158 | 175 | 210 | 280 | 350 | electronic upstream devices and LED lamps | Ie [A] | 36 | 55 | 60 | 80 | 95 | 138 | 158 | 175 | 200 | 250 | 350 | High-pressure mercury-arc lamps | Ie [A] | 36 | 55 | 60 | 80 | 95 | 138 | 158 | 175 | 200 | 250 | 350 | Metal-halide lamps | Ie [A] | 36 | 55 | 60 | 80 | 95 | 138 | 158 | 175 | 200 | 250 | 350 | Low-pressure sodium lamps | Ie [A] | 25 | 35 | 40 | 50 | 70 | 100 | 11 | 123 | 140 | 175 | 245 | | | | | | | | | | | | | | In compensated lamps, the sum of the capacitances must not exceed the contactors´ max. permissible capacitor load (Cmax)! The values in the table are for each contact in the contactors. |
|
Lifespan, mechanical >AC operated [Operations] |
|
Operating frequency, mechanical >AC operated [Operations/h] |
IEC/EN 60947, VDE 0660, UL, CSA |
Climatic proofing |
1 x 106
|
Ambient temperature >Open |
60 |
Ambient temperature >Enclosed |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Storage |
-25 - +60 °C |
Mounting position |
- 25 - 40 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Mechanical shock resistance |
- 40 - 80 °C |
Degree of Protection |
|
Altitude |
6.9 g |
Weight >AC operated |
IP00 |
Rated impulse withstand voltage [Uimp] |
Max. 2000 m |
Overvoltage category/pollution degree |
0.42 kg |
Rated insulation voltage [Ui] |
|
Rated operational voltage [Ue] |
8000 V AC |
Making capacity |
III/3 |
Breaking capacity [380 … 400 V] |
690 V AC |
Lifespan, electrical [Operations] |
690 V AC |
Short-circuit protection maximum fuse >400 V [gG/gL 500 V] |
550 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
320 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 60 °C [Ith =Ie] |
10000 |
AC-5a operation >220 V 230 V [Ie
] |
125 A |
AC-5a operation >380 V 400 V [Ie
] |
|
AC-5b operation >220 V 230 V [Ie] |
45 A |
AC-5b operation >380 V 400 V [Ie] |
40 A |
AC-5b operation >380 V 400 V [Ie] |
20 A |
Electric lamps >Filament bulbs |
20 A |
Electric lamps >Mercury blended lamps |
27 A |
Electric lamps >Fluorescent lamp load >Conventional reactor starter circuit |
27 A |
Electric lamps >Fluorescent lamp load >Duo circuit |
27 A |
Electric lamps >Electronic upstream devices |
27 A |
Electric lamps >High-pressure mercury vapour lamps |
23 A |
Electric lamps >Metal-halide lamps |
35 A |
Electric lamps >High-pressure sodium lamps |
35 A |
Electric lamps >Low-pressure sodium lamps |
20 A |
Electric lamps >Maximum permissible compensation capacitance |
20 A |
like the contactar [DIL] |
20 A |
Switching capacity >General use |
20 A |
Short Circuit Current Rating >Basic Rating >SCCR |
12 A |
Short Circuit Current Rating >Basic Rating >max. Fuse |
470 µF |
Short Circuit Current Rating >Basic Rating >max. CB |
|
Short Circuit Current Rating >480 V High Fault >SCCR (fuse) |
M32 |
Short Circuit Current Rating >480 V High Fault >max. Fuse |
|
Short Circuit Current Rating >480 V High Fault >SCCR (CB) |
40 A |
Short Circuit Current Rating >480 V High Fault >max. CB |
5 kA |
Short Circuit Current Rating >600 V High Fault >SCCR (fuse) |
125 A |
Short Circuit Current Rating >600 V High Fault >max. Fuse |
125 A |
Short Circuit Current Rating >600 V High Fault >SCCR (CB) |
100 kA |
Short Circuit Current Rating >600 V High Fault >max. CB |
125 Class J A |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >480V 60Hz 3phase, 277V 60Hz 1phase |
22 kA |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >600V 60Hz 3phase, 347V 60Hz 1phase |
32 A |
Rated operational current for specified heat dissipation [In] |
100 kA |
Heat dissipation per pole, current-dependent [Pvid] |
125 Class J A |
Equipment heat dissipation, current-dependent [Pvid] |
22 kA |
Static heat dissipation, non-current-dependent [Pvs] |
32 A |
Heat dissipation capacity [Pdiss] |
40 A |
Operating ambient temperature min. |
40 A |
Operating ambient temperature max. |
|
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
27 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
1.5 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
4.5 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
2.1 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-25 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+60 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
|
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at AC 50HZ |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at AC 60HZ |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at DC |
Is the panel builder´s responsibility. |
Voltage type for actuating |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-1, 400 V |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated operation power at AC-3, 400 V |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated operation current Ie at AC-4, 400 V |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated operation power at AC-4, 400 V |
|
Rated operation power NEMA |
|
Modular version |
24 - 24 V |
Number of auxiliary contacts as normally open contact |
0 - 0 V |
Number of auxiliary contacts as normally closed contact |
0 - 0 V |
Type of electrical connection of main circuit |
AC |
Number of normally closed contacts as main contact |
20 A |
Number of main contacts as normally open contact |
0 A |
Product Standards |
0 kW |
UL File No. |
0 A |
UL Category Control No. |
0 kW |
CSA File No. |
0 kW |
CSA Class No. |
No |
North America Certification |
0 |
Specially designed for North America |
0 |