alt
alt

Eaton-DA1-32030FB-B55C
169362 DA1-32030FB-B55C

Variable frequency drive, 230 V AC, 3-phase, 30 A, 7.5 kW, IP55/NEMA 12, Radio interference suppression filter, OLED displayVariable frequency drive, Part group reference (e.g. DIL): DA1, Rated operational voltage: Ue = 230 V AC, 3-phase, 240 V AC, 3-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, 240 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, Rated operational current At 150% overload: Ie = 30 A, Note: Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +40 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 7.5 kW, 150 % Overload: IM = 26.4 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 10 HP, Assigned motor rating 150 % Overload: IM = 28 A, Degree of Protection: IP55/NEMA 12, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): Ethernet IP, DeviceNet, PROFIBUS, PROFINET, Modbus-TCP, EtherCAT, SmartWire-DT, Fitted with: Radio interference suppression filter, Brake chopper, Additional PCB protection, OLED display, Frame size: FS4, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Variable frequency drive, 230 V AC, 3-phase, 30 A, 7.5 kW, IP55/NEMA 12, Radio interference suppression filter, OLED display
Variable frequency drive, Part group reference (e.g. DIL): DA1, Rated operational voltage: Ue = 230 V AC, 3-phase, 240 V AC, 3-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, 240 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, Rated operational current At 150% overload: Ie = 30 A, Note: Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +40 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 7.5 kW, 150 % Overload: IM = 26.4 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 10 HP, Assigned motor rating 150 % Overload: IM = 28 A, Degree of Protection: IP55/NEMA 12, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): Ethernet IP, DeviceNet, PROFIBUS, PROFINET, Modbus-TCP, EtherCAT, SmartWire-DT, Fitted with: Radio interference suppression filter, Brake chopper, Additional PCB protection, OLED display, Frame size: FS4, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Product range Variable frequency drives
Part group reference (e.g. DIL) DA1
Rated operational voltage [Ue] 230 V AC, 3-phase
240 V AC, 3-phase
Output voltage with Ve [U2] 230 V AC, 3-phase
240 V AC, 3-phase
Mains voltage (50/60Hz) [ULN] 200 (-10%) - 240 (+10%) V
At 150% overload [Ie]
Note 30 A
Note Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +40 °C
Note
Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
150 % Overload [P] Overload cycle for 60 s every 600 s
150 % Overload [IM] at 230 V, 50 Hz
Note 7.5 kW
150 % Overload [P] 26.4 A
150 % Overload [IM] at 220 - 240 V, 60 Hz
Degree of Protection 10 HP
Interface/field bus (built-in) 28 A
Fieldbus connection (optional) IP55/NEMA 12
Fitted with OP-Bus (RS485)/Modbus RTU, CANopen®
Parameterization Ethernet IP
DeviceNet
PROFIBUS
PROFINET
Modbus-TCP
EtherCAT
SmartWire-DT
Frame size Radio interference suppression filter
Brake chopper
Additional PCB protection
OLED display
Connection to SmartWire-DT Keypad
Fieldbus
drivesConnect
drivesConnect mobile (App)
Standards FS4
Certifications yes
in conjunction with DX-NET-SWD1 SmartWire DT module
Approvals
Production quality Specification for general requirements: IEC/EN 61800-2
EMC requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5-1
Climatic proofing [ρw] CE, UL, cUL, RCM, UkrSEPRO, EAC
Air quality DNV
Ambient temperature
>Operating ambient temperature min.
RoHS, ISO 9001
Ambient temperature
>Operating ambient temperature max.
< 95%, average relative humidity (RH), non-condensing, non-corrosive %
Ambient temperature 3C3, 3S3
Ambient temperature
>Storage [ϑ]
-10 °C
Radio interference level
>Radio interference class (EMC)
+40 °C
Radio interference level
>Environment (EMC)
operation (with 150 % overload)
Radio interference level
>maximum motor cable length [I]
-40 - +60 °C
Mounting position C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Altitude 1st and 2nd environments as per EN 61800-3
Degree of Protection C2 ≤ 5 m
C3 ≤ 25 m m
Protection against direct contact Vertical
Supply
>Rated operational voltage [Ue]
0 - 1000 m above sea level
Above 1000 m: 1% derating for every 100 m
max. 4000 m m
Supply
>Mains voltage (50/60Hz) [ULN]
IP55/NEMA 12
Supply
>Input current (150% overload) [ILN]
BGV A3 (VBG4, finger- and back-of-hand proof)
Supply
>System configuration
Supply
>Supply frequency [fLN]
230 V AC, 3-phase
240 V AC, 3-phase
Supply
>Frequency range [fLN]
200 (-10%) - 240 (+10%) V
Supply
>Mains switch-on frequency
33.3 A
Power section
>Function
AC supply systems with earthed center point
Power section
>Overload current (150% overload) [IL]
50/60 Hz
Power section
>max. starting current (High Overload) [IH]
48 - 62 Hz
Power section
>Note about max. starting current
Maximum of one time every 30 seconds
Power section
>Output voltage with Ve [U2]
Variable frequency drive with internal DC link and IGBT inverter
Power section
>Output Frequency [f2]
45 A
Power section
>Switching frequency [fPWM]
200 %
Power section
>Operation Mode
for 4 seconds every 40 seconds
Power section
>Frequency resolution (setpoint value) [Δf]
230 V AC, 3-phase
240 V AC, 3-phase
Power section
>Rated operational current
>At 150% overload [Ie]
0 - 50/60 (max. 500) Hz
Power section
>Note
8
adjustable 4 - 24 (audible) kHz
Power section
>Power loss
>Heat dissipation at rated operational current Ie =150 % [PV]
U/f control
Speed control with slip compensation
sensorless vector control (SLV)
optional: Vector control with feedback (CLV)
Power section
>Efficiency [η]
0.1 Hz
Power section
>Maximum leakage current to ground (PE) without motor [IPE]
30 A
Power section
>Fitted with
Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +40 °C
Power section
>Safety function
187.5 W
Power section
>Frame size
97.5 %
Motor feeder
>Note
1.42 mA
Motor feeder
>Note
Radio interference suppression filter
Brake chopper
Additional PCB protection
OLED display
Motor feeder
>Note
STO (Safe Torque Off, SIL2, PLd Cat 3)
Motor feeder
>150 % Overload [P]
FS4
Motor feeder
>Note
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
Motor feeder
>150 % Overload [P]
Overload cycle for 60 s every 600 s
Motor feeder
>maximum permissible cable length [I]
at 230 V, 50 Hz
Motor feeder
>Apparent power
>Apparent power at rated operation 230 V [S]
7.5 kW
Motor feeder
>Apparent power
>Apparent power at rated operation 240 V [S]
at 220 - 240 V, 60 Hz
Motor feeder
>Braking function
>Standard braking torque
10 HP
Motor feeder
>Braking function
>DC braking torque
screened: 100
screened, with motor choke: 200
unscreened: 150
unscreened, with motor choke: 300 m
Motor feeder
>Braking function
>Braking torque with external braking resistance
11.95 kVA
Motor feeder
>Braking function
>minimum external braking resistance [Rmin]
12.47 kVA
Motor feeder
>Braking function
>Switch-on threshold for the braking transistor [UDC]
max. 30 % MN
External control voltage [Uc] max. 100% of rated operational current Ie, variable
Reference voltage [Us] Max. 100% of rated operational current Ie with external braking resistor
Analog inputs 22 Ω
Analog outputs 390 V DC V
Digital inputs
Digital outputs 24 V DC (max. 100 mA) V
Relay outputs 10 V DC (max. 10 mA) V
Interface/field bus (built-in) 2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 150 %
2, parameterizable, 0 - 10 V, 0/4 - 20 mA
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>UL (Class CC or J)
3, parameterizable, max. 30 VDC, max. 5 for non-parameterized analog inputs
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>Notes
2, parameterizable, 24 V DC
Power Wiring
>Mains contactor
>150 % overload (CT/IH, at 50 °C)
2, parameterizable, 1 N/O and 1 changeover contact, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)
Power Wiring
>Main choke
>150 % overload (CT/IH, at 50 °C)
OP-Bus (RS485)/Modbus RTU, CANopen®
Power Wiring
>Radio interference suppression filter (external, 150 %)
Power Wiring
>Radio interference suppression filter, low leakage currents (external, 150 %)
FAZ-B50/3
Power Wiring
>Note regarding radio interference suppression filter
50 A
DC link connection
>Braking resistance
>10 % duty factor (DF)
LPJ fuse used together with JM60100-3 fuse base
DC link connection
>Braking resistance
>20 % duty factor (DF)
DILM17
DC link connection
>Braking resistance
>40 % duty factor (DF)
DX-LN3-040
DC link connection
>Braking resistance
>Notes concerning braking resistances:
DX-EMC34-042
Motor feeder
>motor choke
>150 % overload (CT/IH, at 50 °C)
DX-EMC34-042-L
Motor feeder
>Sine filter
>150 % overload (CT/IH, at 50 °C)
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Motor feeder
>All-pole sine filter
>150 % overload (CT/IH, at 50 °C)
DX-BR022-1K4
Rated operational current for specified heat dissipation [In] DX-BR022-3K1
Heat dissipation per pole, current-dependent [Pvid] DX-BR022-5K1
Equipment heat dissipation, current-dependent [Pvid] The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request.
Static heat dissipation, non-current-dependent [Pvs] DX-LM3-035
Heat dissipation capacity [Pdiss] DX-SIN3-032
Operating ambient temperature min. DX-SIN3-046-A
Operating ambient temperature max.
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
30 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
187.5 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-10 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+40 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Is the panel builder´s responsibility.
Mains voltage Is the panel builder´s responsibility.
Mains frequency Is the panel builder´s responsibility.
Number of phases input Is the panel builder´s responsibility.
Number of phases output Is the panel builder´s responsibility.
Max. output frequency The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Max. output voltage Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Nominal output current I2N Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. output at quadratic load at rated output voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Max. output at linear load at rated output voltage
Relative symmetric net frequency tolerance
Relative symmetric net voltage tolerance 180 - 264 V
Number of analogue outputs 50/60 Hz
Number of analogue inputs 3
Number of digital outputs 3
Number of digital inputs 500 Hz
With control unit 250 V
Application in industrial area permitted 30 A
Application in domestic- and commercial area permitted 7.5 kW
Supporting protocol for TCP/IP 7.5 kW
Supporting protocol for PROFIBUS 10 %
Supporting protocol for CAN 10 %
Supporting protocol for INTERBUS 2
Supporting protocol for ASI 2
Supporting protocol for KNX 2
Supporting protocol for MODBUS 5
Supporting protocol for Data-Highway Yes
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET Yes
Supporting protocol for LON Yes
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFINET CBA Yes
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work Yes
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety Yes
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for BACnet Yes
Supporting protocol for other bus systems No
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET No
Number of HW-interfaces RS-232 Yes
Number of HW-interfaces RS-422 No
Number of HW-interfaces RS-485 No
Number of HW-interfaces serial TTY No
Number of HW-interfaces USB No
Number of HW-interfaces parallel No
Number of HW-interfaces other Yes
With optical interface Yes
With PC connection 0
Integrated breaking resistance 0
4-quadrant operation possible 0
Type of converter 0
Degree of protection (IP) 1
Degree of protection (NEMA) 0
Height 0
Width 0
Depth 0
Product Standards No
UL File No. Yes
UL Category Control No. Yes
CSA File No. Yes
North America Certification U converter
Specially designed for North America IP55
Suitable for 12
Max. Voltage Rating 450 mm
Degree of Protection 173 mm

Benzer Ürünler

Eaton-DA1-32110FB-B55C
Eaton
Eaton-DA1-32150FB-B55C
Eaton
Eaton-DA1-32180FB-B55C
Eaton
Eaton-DA1-32202FB-B55C
Eaton
Eaton-DA1-32248FB-B55C
Eaton
Eaton-DA1-342D2FB-B66C
Eaton
Eaton-DA1-342D2FB-B6SC
Eaton
Eaton-DA1-344D1FB-B66C
Eaton
Eaton-DA1-344D1FB-B6SC
Eaton