Power supply unit, 1p, 192VA, prim 230VAC, sec. 24VAC, 24 V DC, 10 V DCUniversal power supply unit single-phase, safety transformer to IEC/EN 61558-2-2, 2-6, VDE 0570 Part 2-2, 2-6. rated power 192VA, one fuse per output voltage, a changeover contact for monitoring and annunciation, rated input voltage 230V +- 5%, rated output voltage: 24V AC / 8A, 10V DC / 1A, 24V DC / 3A
Power supply unit, 1p, 192VA, prim 230VAC, sec. 24VAC, 24 V DC, 10 V DC
Universal power supply unit single-phase, safety transformer to IEC/EN 61558-2-2, 2-6, VDE 0570 Part 2-2, 2-6. rated power 192VA, one fuse per output voltage, a changeover contact for monitoring and annunciation, rated input voltage 230V +- 5%, rated output voltage: 24V AC / 8A, 10V DC / 1A, 24V DC / 3A
Product range | Universal power supply unit AING |
Basic function | Single-phase power supply |
Rated input voltage | Every output voltage a fuse, an LED and a changeover contact for monitoring and annunciation Non-standard voltages on request |
Rated output voltage | 230± 5 % V |
Rated power | 24 AC, 10 DC, 24 DC V |
Max. output current | 0.192 kVA |
Cu factor | 8 1 3 A |
Notes | 3,60 kg |
Standards >Built and tested to |
Signal contacts Switching voltage max. 250 V AC/110 V DC max. 1 A Switching duty 62 VA/30 W LED indication
Size/part no. FK2 fuses are used. |
Standards >Suitable for use to |
Safety transformer to IEC/EN 61558-2-2/2-6 VDE 0570 part 2-2/2-6 |
Ambient temperature | IEC/EN 60204-1 VDE 0113 |
Terminations | -25 - 40 |
Insulation class | ● |
Rated frequency | B |
Primary tapping | 50 - 60 Hz |
Degree of Protection | ± 5 % |
Separate windings | IP20 |
Fully vacuum-impregnated | ● |
Reinforced insulation | ● |
Rated duty factor | ● |
Rated operational current for specified heat dissipation [In] | 100 % DF |
Heat dissipation per pole, current-dependent [Pvid] | 0 A |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 50 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | -25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+40 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Input voltage at AC 50 Hz | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Input voltage at AC 60 Hz | 230 - 230 V |
Input voltage at DC | 230 - 230 V |
Type of voltage (input voltage) | 0 - 0 V |
Max. input current AC 50 Hz | AC |
Max. input current AC 60 Hz | 0.83 A |
Max. input current DC | 0.83 A |
Type of output voltage | 0 A |
Output voltage at AC 50 Hz | AC/DC |
Output voltage at AC 60 Hz | 24 - 24 V |
Output voltage at DC | 24 - 24 V |
Max. output current AC 50 Hz | 24 - 24 V |
Max. output current AC 60 Hz | 8 A |
Max. output current DC | 8 A |
Power output | 3 A |
Redundancy | 192 W |
Suitable for safety functions | No |
Width | Yes |
Height | 110 mm |
Depth | 155 mm |