alt
alt

PKZM01-1
278479 PKZM01-1
278479

Motor koruyucu devre kesici, 660 V 690 V: 0,55 kW, Ir= 0,63 - 1 A, IP20 IEC/EN60947'ye uygun motor koruyucu devre kesici, 3 kutuplu PKZM01, ayarlanabilir aşırı yük ve gecikmesiz kısa devre açma özellikli, faz hatasına duyarlı, vidalı ve geçmeli bağlantı, kapak montaj boyutu 45 mm, nominal çalışma gerilimi Ue 690V, derece koruma IP20, VDE 0106 T. 100'e göre parmak korumalı, aksesuarlar: yardımcı kontak, gerilim bobini

Motor koruyucu devre kesici, 660 V 690 V: 0,55 kW, Ir= 0,63 - 1 A, IP20
IEC/EN60947'ye uygun motor koruyucu devre kesici, 3 kutuplu PKZM01, ayarlanabilir aşırı yük ve gecikmesiz kısa devre açma özellikli, faz hatasına duyarlı, vidalı ve geçmeli bağlantı, kapak montaj boyutu 45 mm, nominal çalışma gerilimi Ue 690V, derece koruma IP20, VDE 0106 T. 100'e göre parmak korumalı, aksesuarlar: yardımcı kontak, gerilim bobini

Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation
Basic function Motor protection
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Contact sequence Screw terminals
AC-3
>220 V 230 V 240 V [P]
121S003
AC-3
>380 V 400 V 415 V [P]
AC-3
>440 V [P]
0.12 kW
AC-3
>500 V [P]
0.25 kW
AC-3
>660 V 690 V [P]
0.25 kW
Rated uninterrupted current [Iu] 0.37 kW
Overload releases [Ir ] 0.55 kW
short-circuit release [Irm ]
>max. [Irm ]
1 A
Phase-failure sensitivity
Notes 0.63 - 1 A
Standards 15.5 A
Climatic proofing IEC/EN 60947-4-1, VDE 0660 Part 102
Ambient temperature
>Storage
Overload trigger: tripping class 10 A
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height.
Ambient temperature
>Open
Ambient temperature
>Enclosed
IEC/EN 60947, VDE 0660,UL, CSA
Mounting position Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Direction of incoming supply - 40 - 80 °C
Degree of protection
>Device
-25 - +55 °C
Degree of protection
>Terminations
- 25 - 40 °C
Protection against direct contact when actuated from front (EN 50274) 1210DRW-68
Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 as required
Altitude IP20
Terminal capacity main cable
>Screw terminals
>Solid
IP00
Terminal capacity main cable
>Screw terminals
>Flexible with ferrule to DIN 46228
Finger and back-of-hand proof
Terminal capacity main cable
>Screw terminals
>Solid or stranded
25 g
Terminal capacity main cable
>Screw terminals
>Stripping length
Max. 2000 m
Specified tightening torque for terminal screws
>Main cable
1 x (1 - 6)
2 x (1 - 6) mm2
Rated impulse withstand voltage [Uimp] 1 x (1 - 6)
2 x (1 - 6) mm2
Overvoltage category/pollution degree 18 - 10 AWG
Rated operational voltage [Ue ] 10 mm
Rated uninterrupted current = rated operational current [Iu = Ie ] 1.7 Nm
Rated frequency [f]
Current heat loss (3 pole at operating temperature) 6000 V AC
Impedance per pole III/3
Lifespan, mechanical [Operations] 690 V AC
Lifespan, electrical (AC-3 at 400 V)
>Lifespan, electrical [Operations]
1 A
Max. operating frequency 40 - 60 Hz
Short-circuit rating
>DC
>Short-circuit rating
5.33 W
Short-circuit rating
>DC
>Notes
1700 mΩ
Motor switching capacity
>AC-3 (up to 690V)
0.05 x 106
Motor switching capacity
>DC-5 (up to 250V)
0.05 x 106
Temperature compensation
>to IEC/EN 60947, VDE 0660
25 Ops/h
Temperature compensation
>Operating range
60 kA
Temperature compensation residual error for T > 40 °C up to 250 V
Setting range of overload releases 1 A
short-circuit release 1 (3 contacts in series) A
Short-circuit release tolerance
Phase-failure sensitivity - 5…40 °C
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
- 25…55 °C
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
≦ 0.25 %/K
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
0.6 - 1 x Iu
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
Basic device, fixed: 15.5 x Iu
Short Circuit Current Rating, group protection
>600 V High Fault
>SCCR (fuse)
± 20%
Short Circuit Current Rating, group protection
>600 V High Fault
>max. Fuse
IEC/EN 60947-4-1, VDE 0660 Part 102
Short Circuit Current Rating, group protection
>600 V High Fault
>SCCR (CB)
Short Circuit Current Rating, group protection
>600 V High Fault
>max. CB
Hinweis: Motorleistung in diesem Bereich nach Bemessungsstrom berechnen. Angegebene Werte nach NEC Table 430-150 HP
Rated operational current for specified heat dissipation [In] Hinweis: Motorleistung in diesem Bereich nach Bemessungsstrom berechnen. Angegebene Werte nach NEC Table 430-150 HP
Heat dissipation per pole, current-dependent [Pvid] Hinweis: Motorleistung in diesem Bereich nach Bemessungsstrom berechnen. Angegebene Werte nach NEC Table 430-150 HP
Equipment heat dissipation, current-dependent [Pvid] Hinweis: Motorleistung in diesem Bereich nach Bemessungsstrom berechnen. Angegebene Werte nach NEC Table 430-150 HP
Static heat dissipation, non-current-dependent [Pvs] 50 kA
Heat dissipation capacity [Pdiss] 600 A
Operating ambient temperature min. 50 kA
Operating ambient temperature max. 600 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
1 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
1.78 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
5.33 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
-25 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
+55 °C
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Overload release current setting Is the panel builder´s responsibility.
Adjustment range undelayed short-circuit release Is the panel builder´s responsibility.
With thermal protection Is the panel builder´s responsibility.
Phase failure sensitive Is the panel builder´s responsibility.
Switch off technique Is the panel builder´s responsibility.
Rated operating voltage The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated permanent current Iu Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power at AC-3, 230 V Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power at AC-3, 400 V The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Type of electrical connection of main circuit
Type of control element
Device construction 0.63 - 1 A
With integrated auxiliary switch 15.5 - 15.5 A
With integrated under voltage release Yes
Number of poles Yes
Rated short-circuit breaking capacity lcu at 400 V, AC Thermomagnetic
Degree of protection (IP) 690 - 690 V
Height 1 A
Width 0.12 kW
Depth 0.25 kW
Product Standards Screw connection
UL File No. Push button
UL Category Control No. Built-in device fixed built-in technique
CSA File No. No
CSA Class No. No
North America Certification 3
Specially designed for North America 50 kA
Suitable for IP20
Accessories 93 mm
Characteristic curve 45 mm
Characteristic curve 90.5 mm
Characteristic curve IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.