alt
alt

750-667/000-003
Fault-tolerant 4/4 channel digital input/output

Fail-safe 4/4-channel digital input/output; 24VDC; 2 A; PROFIsafe V2.0 iPar; yellowThe 75x-667/000-003 module is equipped with 4 power outputs (O1 .. O4) and 4 clock sensitive inputs (I1 .. I4). Sensors can be powered directly with 24V or with 2 different clocked outputs (T1 ... T2). The inputs are connected via contacts to potential-free emergency switches, safety door switches, mode selectors and safety sensors as well as semiconductor outputs (e.g. light barriers, PLC outputs). The power outputs switch both DC13 resistive and inductive loads with a rated current of up to 2A, without requiring additional external circuitry. The power outputs operate in both bipolar (rising edge/falling edge switching) and unipolar (common potential on one side of the load) mode. The module monitors short circuits, reverse circuits and 24V voltage supply from separate sources. Monitoring and safety-related parameters (e.g. operating modes, shutdown test pulses, mismatch or filter times) can be set with WAGO-I/O-CHECK. The configuration tool can be easily integrated into engineering systems that support CC2 and CC3 ride-hailing interfaces (TCI). When changing modules, parameters are automatically downloaded to the control unit from the PROFIsafe-compatible iPar server, depending on the settings. The PROFIsafe address can be set using the DIP switch on the side of the module or via WAGO-I/O-CHECK. The modules support both PROFIsafe V1 (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols. The individual input modules can be arranged in any combination when configuring the fieldbus node. To protect the module against voltage surges (overvoltage protection in accordance with IEC 61000-4-5), the filter module 750-626 or an external surge filter must be used for the 24V power supply. For more information, see the product user manual (available in German and English).

Fail-safe 4/4-channel digital input/output; 24VDC; 2 A; PROFIsafe V2.0 iPar; yellow


The 75x-667/000-003 module is equipped with 4 power outputs (O1 .. O4) and 4 clock sensitive inputs (I1 .. I4). Sensors can be powered directly with 24V or with 2 different clocked outputs (T1 ... T2).

The inputs are connected via contacts to potential-free emergency switches, safety door switches, mode selectors and safety sensors as well as semiconductor outputs (e.g. light barriers, PLC outputs). The power outputs switch both DC13 resistive and inductive loads with a rated current of up to 2A, without requiring additional external circuitry.

The power outputs operate in both bipolar (rising edge/falling edge switching) and unipolar (common potential on one side of the load) mode.

The module monitors short circuits, reverse circuits and 24V voltage supply from separate sources. Monitoring and safety-related parameters (e.g. operating modes, shutdown test pulses, mismatch or filter times) can be set with WAGO-I/O-CHECK.

The configuration tool can be easily integrated into engineering systems that support CC2 and CC3 ride-hailing interfaces (TCI).

When changing modules, parameters are automatically downloaded to the control unit from the PROFIsafe-compatible iPar server, depending on the settings. The PROFIsafe address can be set using the DIP switch on the side of the module or via WAGO-I/O-CHECK.

The modules support both PROFIsafe V1 (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols.

The individual input modules can be arranged in any combination when configuring the fieldbus node.

To protect the module against voltage surges (overvoltage protection in accordance with IEC 61000-4-5), the filter module 750-626 or an external surge filter must be used for the 24V power supply.

For more information, see the product user manual (available in German and English).

Number of digital inputs 4
Number of digital outputs 4
Total number of channels (module) 8
Achievable safety classes SIL 3; Cat. 4, PL e
Sinyal tipi Voltage
Type of signal voltage DC 24 V
Sensor connection 4 x (sicherer Eingang mit Testpuls)
Actuator connection 4 x (fail-safe output with test pulse)
Input characteristic clock sensitive
Giriş karakteristikleri Type 1
Input current per channel for signal (1) typ. 2,2mA
Output switching design Power outputs
Output current per channel 2A
Çıkış akımı (modül) 8A
Çıkış akımı short-circuit-protected
Switching frequency max. 50 Hz; Ohmsche Last
Switching frequency max. (2) 0,1 Hz; Induktive Last
Her kanal için kapasitif yük O1 ... O4; 2,2 µF
Signal frequency max. 50Hz
Switching frequency max. 50Hz
Lastart der Schaltfrequenz Ohmsche Last
Test pulse duration min. 0ms
Test pulse duration max. 500ms
System supply voltage DC 5 V; via data contacts
Current consumption, system supply (5 V) 180mA
Field supply voltage DC 24 V (-15 … +20 %); über Leistungskontakte (Einspeisung über Messerkontakt; Weiterleitung über Federkontakt)
Current consumption, field supply (module with no external load) 20mA
İzolasyon 500 V sistem/besleme
Indicators LED (A-D) green/red: Status/Error I1 … I4; LED (I-M) green/red: Status/error O1 … O4;LED (E) red: Group error; LED (F-H) green/red: Diagnostics
Number of incoming power jumper contacts 2
Number of outgoing power jumper contacts 2
Current carrying capacity of the power jumper contacts 10A
Connection technology: In-/Outputs 16 x CAGE CLAMP®
Connection type (1) Inputs/Outputs
Tek damarlı boylar 0,08 … 2,5 mm² / 28 … 14 AWG
İnce bükümlü kablolar 0,08 … 2,5 mm² / 28 … 14 AWG
Sıyırma uzunluğu 8 … 9 mm / 0.31 … 0.35 inch
Width 24 mm / 0.945 inch
Height 67,8 mm / 2.669 inch
DIN rayın üst kenarından yükseklik 60,6 mm / 2.386 inch
Depth 100 mm / 3.937 inch
Montaj tipi DIN 35 ray
Renk sarı
Gövde malzemesi Polycarbonate, polyamide 6.6
Ağırlık 104,4
Uygunluk işareti CE
Surrounding air (operating) temperature 0 … 55 °C
Surrounding air (storage) temperature -40 … 85 °C
Koruma sınıfı IP20
Kirlilik derecesi (5) 2 per IEC 61131-2
Çalışma yüksekliği 0 … 2000 m
Montaj pozisyonu horizontal (standing/lying) or vertical
Nısbi nem (yoğuşmasız) 95%
Titreşime dayanıklı 4g per IEC 60068-2-6
Darbe direnci 15g per IEC 60068-2-27
EMV-Störfestigkeit acc. to EN 61000-6-2, marine applications
EMU: 1 - enterferans emisyonu acc. to EN 61000-6-4, marine applications
Kirletici maddelere maruziyet Per IEC 60068-2-42 and IEC 60068-2-43
Permissible H2S contaminant concentration at a relative humidity 75 % 10ppm
Permissible SO2 contaminant concentration at a relative humidity 75 % 25ppm
Product Group 15 (Remote I/O)
SAP´den ambalaj tipi BOX
Country of origin DE
GTIN 4050821038764
Customs Tariff No. 85389099990

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.