alt
alt

750-493/025-000
3 Phase Power Measurement

3 Phase Power Measurement; 480VAC, 1A; Wide. heat; Light grey750-493 3-Phase Power Measurement Module measures electrical data in a three-phase electrical network. Voltage is measured via mains connection L1, L2, L3 and N. Three phase current is fed to IL1, IL2, IL3 and IN via current transformers. The 750-493 Module sends root mean square values to the process image without requiring high computing power from the controller. The effective power (P) and energy consumption (W) for each phase are calculated by the module using the root mean square values of all measured voltages (V) and currents (I). For example, both apparent power (S) and phase shift angle (φ) can be easily obtained from these values. Therefore, the 750-493 Module provides comprehensive network analysis via fieldbus. Values such as effective and apparent power consumption or load status enable the operator to optimize the power fed to the drive or machine. In this way, the installation can be protected from damage and malfunction.

3 Phase Power Measurement; 480VAC, 1A; Wide. heat; Light grey


750-493 3-Phase Power Measurement Module measures electrical data in a three-phase electrical network.

Voltage is measured via mains connection L1, L2, L3 and N.

Three phase current is fed to IL1, IL2, IL3 and IN via current transformers.

The 750-493 Module sends root mean square values to the process image without requiring high computing power from the controller. The effective power (P) and energy consumption (W) for each phase are calculated by the module using the root mean square values of all measured voltages (V) and currents (I). For example, both apparent power (S) and phase shift angle (φ) can be easily obtained from these values.

Therefore, the 750-493 Module provides comprehensive network analysis via fieldbus. Values such as effective and apparent power consumption or load status enable the operator to optimize the power fed to the drive or machine. In this way, the installation can be protected from damage and malfunction.

Number of measurement inputs 6 (3 voltage measurement inputs, 3 current measurement inputs)
Sinyal tipi Power measurement
Sinyal şekli herhangi (maksimum frekansı dikkate alınarak)
Çözünürlük [bit] 16Bit
Bit genişliği 2 x 48-bit veri, 2 x 24-bit kontrol/durum (seçenek)
Giriş direnci gerilim yolu (tip.) 1071
Input resistance current path typ. 22 mΩ
Bezug für Messfehler AC Strom/Spannung
Messfehler, Bezugstemperatur 25°C
Messfehler, Abweichung max. vom Messbereichsendwert 0,6%
Ölçüm akımı (maks.) 1 A
Ölçüm gerilimi maks. 500 VAC, 3 faz
Ölçme çevrim süresi Adjustable measuring cycle time for Min_Max_Values
Etkin DC filtre ile frekans aralığı 10 … 2000 Hz
Etkin olmayan DC filtre ile frekans aralığı 0 … 2000 Hz
Frekans aralığı, güç kaynağı frekansı 45 … 65 Hz
Operating frequency 7,2kHz
Anma gerilimi ULN = 277 V AC/DC; ULL = 480 VAC
Ölçülen değerler Efektif güç, enerji, güç faktörü (cos ϕ)
Messkomponenten Evaluating
Ölçme prosedürü Hakiki RMS ölçümü
System supply voltage DC 5 V; via data contacts
Current consumption, system supply (5 V) 100mA
İzolasyon 4 kV system/field
Rated surge voltage 4 kV
Connection technology: In-/Outputs 8 x CAGE CLAMP®
Connection type (1) Inputs/Outputs
Tek damarlı boylar 0,08 … 2,5 mm² / 28 … 14 AWG
İnce bükümlü kablolar 0,08 … 2,5 mm² / 28 … 14 AWG
Sıyırma uzunluğu 8 … 9 mm / 0.31 … 0.35 inch
Width 12 mm / 0.472 inch
Height 67,8 mm / 2.669 inch
DIN rayın üst kenarından yükseklik 60,6 mm / 2.386 inch
Depth 100 mm / 3.937 inch
Montaj tipi DIN 35 ray
Renk açık gri
Gövde malzemesi Polycarbonate, polyamide 6.6
Ağırlık 50
Uygunluk işareti CE
Surrounding air (operating) temperature -20 … 60 °C
Surrounding air (storage) temperature -40 … 85 °C
Koruma sınıfı IP20
Kirlilik derecesi (5) 2 per IEC 61131-2
Çalışma yüksekliği 0 … 2000 m
Montaj pozisyonu horizontal (standing/lying) or vertical
Nısbi nem (yoğuşmasız) 95%
Relative humidity Short-term condensation per Class 3K6/IEC EN 60721-3-3 and E DIN 40046-721-3, taking a temperature range of −20 … +60 °C into consideration (except wind-driven precipitation, water and ice formation)
Titreşime dayanıklı acc. to IEC 60068-2-6
Darbe direnci 15g per IEC 60068-2-27
EMV-Störfestigkeit acc. to EN 61000-6-2
EMU: 1 - enterferans emisyonu acc. to EN 61000-6-3
Kirletici maddelere maruziyet Per IEC 60068-2-42 and IEC 60068-2-43
Permissible H2S contaminant concentration at a relative humidity 75 % 10ppm
Permissible SO2 contaminant concentration at a relative humidity 75 % 25ppm
Product Group 15 (Remote I/O)
SAP´den ambalaj tipi BOX
Country of origin DE
GTIN 4055143085878
Customs Tariff No. 85389099990

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.