alt
alt

XIOC-32DI
267411 XIOC-32DI
267411

Digital input card for XC100/200, 24 V DC, 32DIModular programmable controllers XC-CPU1xx and XC-CPU2xx offer an outstanding level of scalability. Different CPU performance classes and a wide range of expansion modules (XIOC module) are available. The compact PLCs XC152 facilitate cost-effective solutions of automation tasks using their computing power, the SmartWire-DT interface as well as a whole range of further interfaces. a particular feature is the ability to integrate the product into modern communication concepts. Data exchange via the Ethernet interface to OPC clients or the integrated WEB servers enables the creation of innovative solutions.

Digital input card for XC100/200, 24 V DC, 32DI
Modular programmable controllers XC-CPU1xx and XC-CPU2xx offer an outstanding level of scalability. Different CPU performance classes and a wide range of expansion modules (XIOC module) are available. The compact PLCs XC152 facilitate cost-effective solutions of automation tasks using their computing power, the SmartWire-DT interface as well as a whole range of further interfaces. a particular feature is the ability to integrate the product into modern communication concepts. Data exchange via the Ethernet interface to OPC clients or the integrated WEB servers enables the creation of innovative solutions.

Function Digital modules
Description Compact I/O system for connection to XC100/200 Modular PLCs
XC100/200 expandable with up to 15 XI/OC modules
Optionally, screw terminals or spring-loaded terminals for digital/analog modules
Standards 32 inputs, 24 V DC
Ambient temperature
Storage [ϑ] IEC/EN 61131-2
EN 50178
Vibration resistance 0 - +55 °C
Mechanical shock resistance -25 - +70 °C
Impact resistance 10 - 57 Hz ±0.075 mm
57 - 150 Hz ±1.0 mm
Overvoltage category/pollution degree 15
Shock duration 11 ms g
Protection class 500 g/⌀ 50 mm ±25 g
Degree of Protection II/2
Emitted interference 1
Weight IP20
Rated voltage [Ue ] DIN/EN 55011/22, Class A
Admissible range 0.16 kg
Neutral poles
>Duration of dip
Neutral poles
>Repetition rate
24 (12) V DC
Residual ripple 20.4 – 28.8 (11.8 – 14.4)
Maximum power loss [Pv] 10 ms
Input type 1 s
Input voltage ≦ 5 %
Admissible range 3.8 W
Input current
Input impedance DC input
Voltage level to IEC 61131-2, limit value type 1
>ON
24 V DC
Voltage level to IEC 61131-2, limit value type 1
>OFF
20.4 - 28.8 V DC
Input delay
>Off → On
>Debounce ON
Normally 4.3 mA
Input delay
>On → Off
>Debounce ON
Normally 5.6 kΩ
Input channels ≧ 15 DC V
Channels with the same reference potential ≦ 5 DC V
Potential isolation ≦ 5 (normally 4) ms
Indicating elements ≦ 5 (normally 4) ms
Terminals 32 Qty.
Internal current consumption (5 V DC) 32 Number
Short-circuit protection Opto-isolated
Short-circuit protection 16 LED (green), switchable: 0 - 15, 16 - 31
Rated operational current for specified heat dissipation [In] XIOC-TERM32 (connector and cable)
Heat dissipation per pole, current-dependent [Pvid] 100 mA
Equipment heat dissipation, current-dependent [Pvid]
Static heat dissipation, non-current-dependent [Pvs] Yes
Heat dissipation capacity [Pdiss] Yes
Operating ambient temperature min.
Operating ambient temperature max.

For clamp terminals: connectors and cables are not included in delivery.

10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
3.8 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
+55 °C
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Supply voltage AC 50 Hz Is the panel builder´s responsibility.
Supply voltage AC 60 Hz Is the panel builder´s responsibility.
Supply voltage DC Is the panel builder´s responsibility.
Voltage type of supply voltage Is the panel builder´s responsibility.
Number of digital inputs Is the panel builder´s responsibility.
Number of digital outputs The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Digital inputs configurable Is the panel builder´s responsibility.
Digital outputs configurable Is the panel builder´s responsibility.
Input current at signal 1 The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Permitted voltage at input
Type of voltage (input voltage)
Type of digital output 0 - 0 V
Output current 0 - 0 V
Permitted voltage at output 20.4 - 28.8 V
Type of output voltage DC
Short-circuit protection, outputs available 32
Redundancy 0
Type of electric connection No
Time delay at signal exchange No
Suitable for safety functions 4.3 mA
Category according to EN 954-1 20.4 - 28.8 V
SIL according to IEC 61508 DC
Performance level acc. EN ISO 13849-1 None
Appendant operation agent (Ex ia) 0 A
Appendant operation agent (Ex ib) 20.4 - 28.8 V
Explosion safety category for gas DC
Explosion safety category for dust No
Width No
Height Plug-in connection
Depth 0 - 0 ms
Product Standards No
UL File No.
UL Category Control No. None
CSA File No. None
CSA Class No. No
North America Certification No
Specially designed for North America None
Current Limiting Circuit-Breaker None
Degree of Protection 30 mm

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.