I/O expansion, For use with easyE4, 12/24 V DC, 24 V AC, Inputs expansion (number) digital: 8, screw terminalI/O expansion, Supply voltage: 12/24 V DC, 24 V AC, Can be used via easyConnect, Mounting position: Vertical or horizontal, Protection type (IEC/EN 60529, EN50178, VBG 4): IP20, Standards: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 61131-2, EN 61010, EN 50178, cULus per UL 61010, CSA C22.2 No.61010

I/O expansion, For use with easyE4, 12/24 V DC, 24 V AC, Inputs expansion (number) digital: 8, screw terminal
I/O expansion, Supply voltage: 12/24 V DC, 24 V AC, Can be used via easyConnect, Mounting position: Vertical or horizontal, Protection type (IEC/EN 60529, EN50178, VBG 4): IP20, Standards: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 61131-2, EN 61010, EN 50178, cULus per UL 61010, CSA C22.2 No.61010

Product range Control relays easyE4
Subrange easyE4 digital input/output enhancements
Basic function easyE4 extensions
Description Input/output extension for easyE4 control relay
Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225)
Rated operating voltage 12V DC, 24V DC or 24V AC
Digital inputs: 8
Digital outputs: 8 relays
Screw terminals
Inputs expansion (number)
Display digital: 8
Software
Supply voltage with diagnostic LED
For use with EASYSOFT-SWLIC/easySoft 7
Standards 12/24 V DC
24 V AC
Approvals
>Approvals
easyE4
Approvals
>certificate
Approvals
>shipping classification
EN 61000-6-2
EN 61000-6-3
IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-30
IEC 61131-2
EN 61010
EN 50178
Approvals cULus
Dimensions (W x H x D) CE
Weight DNV GL
Mounting 0000SPC-596
Connection type 71.5 x 90 x 58 mm
Screw terminals
>Solid
0.229 kg
Screw terminals
>flexible
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Screw terminals
>Solid or flexible conductor, with ferrule
screw terminal
Screw terminals
>Solid or stranded
Screw terminals
>Standard screwdriver
0.2 - 4 mm2
Screw terminals
>Tightening torque
0.2 - 2.5 mm2
Screw terminals
>Stripping length
0,2 - 2,5 mm2
Operating ambient temperature 22 - 12 AWG
Condensation 0.8 x 3.5 mm
Storage [ϑ] 0.5 - 0.7 Nm
relative humidity 6.5 mm
Air pressure (operation)
Protection type (IEC/EN 60529, EN50178, VBG 4) -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
Vibrations Take appropriate measures to prevent condensation
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms -40 - +70 °C
Drop to IEC/EN 60068-2-31 [Drop height] in accordance with IEC 60068-2-30, IEC 60068-2-78
5 - 95 %
Free fall, packaged (IEC/EN 60068-2-32) 795 - 1080 hPa
Mounting position
Overvoltage category/pollution degree IP20
Electrostatic discharge (ESD)
>applied standard
In accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 - 57
constant acceleration 2 g: 57 - 150 Hz
Electrostatic discharge (ESD)
>Air discharge
18 Impacts
Electrostatic discharge (ESD)
>Contact discharge
50 mm
Electromagnetic fields (RFI) to IEC EN 61000-4-3 0.3 m
Radio interference suppression Vertical or horizontal
Burst
power pulses (Surge) III/2
Immunity to line-conducted interference to (IEC/EN 61000-4-6) according to IEC EN 61000-4-2
Clearance in air and creepage distances 8 kV
Insulation resistance 6 kV
Rated operational voltage [Ue] 0.8 - 1.0 GHz: 10
1.4 - 2 GHz: 3
2.0 - 2.7 GHz: 1 V/m
Permissible range [Ue] EN 61000-6-3 Class B
Residual ripple according to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2 kV
Protection against polarity reversal according to IEC/EN 61000-4-5
1 kV (supply cables, symmetrical)
2 kV (supply cables, asymmetrical)
Frequency 10 V
Input current
Voltage dips nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Fuse in accordance with EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Power loss [P]
Heat dissipation at 24 V DC 12/24 DC (-15/+20%)
24 AC (-15/+10%) V
Number 10.2 - 28.8 V DC
20.4 - 26.4 V AC
Potential isolation ≦ 5 %
Rated operational voltage [Ue] yes
Input voltage 50/60 (± 5%) Hz
Input current at signal 1 max. 200 mA at 12 V DC
max. 125 mA at 24 V DC
Deceleration time ≤ 20 ms at 24 V AC
10 ms at 24 V DC
1 ms at 12 V DC ms
Cable length ≧ 1A (T) A
Number Normally 3 W
Potential isolation 3 W
Rated operational voltage [Ue]
Input voltage 8
Input current at signal 1 from power supply: no
between inputs: no
from the outputs: yes
to base unit: yes
to expansion devices: yes
Deceleration time 12 V DC
Cable length Condition 0: ≦ 5 (I1 - I8)
Condition 1: ≧ 8 (I1 - I8) V DC
Number 1.75 mA (I1 - I8) mA
Potential isolation type 0.2 (0 -> 1)
type 0.15 (1 -> 0) ms
Rated operational voltage [Ue] 100 (unshielded) m
Input voltage (AC = sinusoidal) [Ue]
Rated frequency 8
Input current at signal 1 from power supply: no
between inputs: no
from the outputs: yes
to base unit: yes
to expansion devices: yes
Deceleration time 24 V DC
Cable length Signal 0: ≦ 5 (I1 - I8)
Condition 1: ≧ 15 (I1 - I8) V DC
Number 3.3 (I5 - I8) mA
Outputs in groups of type 0.1 (0 -> 1)
type 0.2 (1 -> 0) ms
Parallel switching of outputs for increased output 100 (unshielded) m
Protection of an output relay
Potential isolation 8
Contacts
>Conventional thermal current (10 A UL)
from power supply: no
between inputs: no
from the outputs: yes
to base unit: yes
to expansion devices: yes
Contacts
>Recommended for load: 12 V AC/DC
24 V AC
Contacts
>Rated impulse withstand voltage Uimp of contact coil
Status 0: ≦ 5 (I1 - I8)
Condition 1: ≧ 14 (I1 - I8) V
Contacts
>Rated operational voltage [Ue]
50/60 Hz
Rated insulation voltage [Ui] I5 - I8: 3.5 (at 24 VAC/DC) mA
Safe isolation according to EN 50178 type 25⁄21 (0 - > 1/1 -> 0, 50/60Hz) ms
Making capacity
>AC–-15, 250 V AC, 3 A (600 ops./h) [Operations]
40 (unshielded) m
Making capacity
>DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
Breaking capacity
>AC-15, 250 V AC, 3 A (600 Ops./h) [Operations]
8
Breaking capacity
>DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
1
Filament bulb load
>1000 W at 230/240 V AC [Operations]
Not permitted
Filament bulb load
>500 W at 115/120 V AC [Operations]
B16 circuit breaker or 8 A (T) fuse
Fluorescent lamp load
>Fluorescent lamp load 10 x 58 W at 230/240 V AC
>With upstream electrical device [Operations]
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
from power supply: yes
From the inputs: yes
between outputs: yes
to expansion devices: yes
Fluorescent lamp load
>Fluorescent lamp load 10 x 58 W at 230/240 V AC
>Uncompensated [Operations]
5 A
Fluorescent lamp load
>Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations]
> 500 mA
Switching frequency
>Mechanical operations
6 kV
Switching frequency
>Switching frequency
240 V AC
Switching frequency
>Resistive load/lamp load
240 V AC
Switching frequency
>Inductive load
300 between coil and contact
300 between two contacts V AC
UL/CSA
>Uninterrupted current at 240 V AC
300000
UL/CSA
>Uninterrupted current at 24 V DC
200000
UL/CSA
>AC
>Control Circuit Rating Codes (utilization category)
300000
UL/CSA
>AC
>Max. rated operational voltage
200000
UL/CSA
>AC
>max. thermal continuous current cos ϕ = 1 at B 300
25000
UL/CSA
>AC
>max. make/break cos ϕ ≠ capacity 1 at B 300
25000
UL/CSA
>DC
>Control Circuit Rating Codes (utilization category)
25000
UL/CSA
>DC
>Max. rated operational voltage
25000
UL/CSA
>DC
>Max. thermal uninterrupted current at R 300
25000
UL/CSA
>DC
>Max. make/break capacity at R 300
10 x 106
Power loss [P] 10 Hz
Static heat dissipation, non-current-dependent [Pvs] 2 Hz
Operating ambient temperature min. 0.5 Hz
Operating ambient temperature max. 5 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
5 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
B 300 Light Pilot Duty
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
300 V AC
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
5 A
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
3600/360 VA
10.2 Strength of materials and parts
>10.2.5 Lifting
R 300 Light Pilot Duty
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
300 V DC
10.2 Strength of materials and parts
>10.2.7 Inscriptions
1 A
10.3 Degree of protection of ASSEMBLIES 28/28 VA
10.4 Clearances and creepage distances
10.5 Protection against electric shock 3 W
10.6 Incorporation of switching devices and components
10.7 Internal electrical circuits and connections 3 W
10.8 Connections for external conductors -25 °C
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
+55 °C
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Meets the product standard´s requirements.
Supply voltage AC 50 Hz Does not apply, since the entire switchgear needs to be evaluated.
Supply voltage AC 60 Hz Does not apply, since the entire switchgear needs to be evaluated.
Supply voltage DC Meets the product standard´s requirements.
Voltage type of supply voltage Meets the product standard´s requirements.
Switching current Meets the product standard´s requirements.
Number of analogue inputs Does not apply, since the entire switchgear needs to be evaluated.
Number of analogue outputs Does not apply, since the entire switchgear needs to be evaluated.
Number of digital inputs Is the panel builder´s responsibility.
Number of digital outputs Is the panel builder´s responsibility.
With relay output Is the panel builder´s responsibility.
Number of HW-interfaces industrial Ethernet Is the panel builder´s responsibility.
Number of interfaces PROFINET Is the panel builder´s responsibility.
Number of HW-interfaces RS-232 The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of HW-interfaces RS-422 Is the panel builder´s responsibility.
Number of HW-interfaces RS-485 Is the panel builder´s responsibility.
Number of HW-interfaces serial TTY The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of HW-interfaces USB
Number of HW-interfaces parallel
Number of HW-interfaces Wireless 20.4 - 28.8 V
Number of HW-interfaces other 20.4 - 28.8 V
With optical interface 10.2 - 28.8 V
Supporting protocol for TCP/IP AC/DC
Supporting protocol for PROFIBUS 5 A
Supporting protocol for CAN 0
Supporting protocol for INTERBUS 0
Supporting protocol for ASI 8
Supporting protocol for KNX 8
Supporting protocol for MODBUS Yes
Supporting protocol for Data-Highway 0
Supporting protocol for DeviceNet 0
Supporting protocol for SUCONET 0
Supporting protocol for LON 0
Supporting protocol for PROFINET IO 0
Supporting protocol for PROFINET CBA 0
Supporting protocol for SERCOS 0
Supporting protocol for Foundation Fieldbus 0
Supporting protocol for EtherNet/IP 0
Supporting protocol for AS-Interface Safety at Work 2
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth No
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
IO link master No
Redundancy No
With display No
Degree of protection (IP) No
Basic device No
Expandable No
Expansion device No
With timer No
Rail mounting possible No
Wall mounting/direct mounting No
Front build in possible No
Rack-assembly possible No
Suitable for safety functions No
Category according to EN 954-1 No
SIL according to IEC 61508 No
Performance level acc. EN ISO 13849-1 No
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Explosion safety category for gas No
Explosion safety category for dust No
Width No
Height IP20
Depth No
UL File No. Yes
UL Category Control No. Yes
North America Certification No
Degree of Protection Yes

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

EASY-NT-RJ45
Eaton
EASY-E4-UC-12RC1
Eaton
EASY-E4-UC-12RCX1
Eaton
EASY-E4-DC-12TC1
Eaton
EASY-E4-DC-12TCX1
Eaton
EASY-E4-AC-12RC1
Eaton
EASY-E4-AC-12RCX1
Eaton
EASY-E4-UC-8RE1
Eaton