Basic function |
easyE4 base device |
Description |
Electronic control relay with display with Ethernet interface Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225) Rated operating voltage 100 to 240 VAC or 100 to 240 VDC (cULus: 100 to 110 VDC) Digital inputs: 8 Digital outputs: 4 relays Screw terminals Delivery with customized user program is possible via Item (Y7) -2010781 EASY-COMBINATION |
Digital |
|
Quantity of outputs |
8 |
Real time clock |
|
Display & keypad |
Relay: 4 |
Expansions |
|
Supply voltage |
✔ |
Software |
✔ |
Connection type |
Expandable networkable (Ethernet) |
Standards |
100 - 240 V AC, 100 - 240 V DC (cULus: 100 - 110 V DC) |
Approvals >Approvals |
EASYSOFT-SWLIC/easySoft 7 |
Approvals >certificate |
screw terminal |
Approvals >shipping classification |
|
Approvals |
EN 61000-6-2 EN 61000-6-3 IEC 60068-2-6 IEC 60068-2-27 IEC 60068-2-30 IEC 61131-2 EN 61010 EN 50178 |
Dimensions (W x H x D) |
cULus |
Weight |
CE |
Mounting |
DNV GL |
Connection type |
|
Ethernet >Connections |
71.5 x 90 x 58 mm |
Ethernet >Cable |
0.226 kg |
Screw terminals >Solid |
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Screw terminals >flexible |
screw terminal |
Screw terminals >Solid or flexible conductor, with ferrule |
RJ45 plug, 8-pin |
Screw terminals >Solid or stranded |
CAT5 |
Screw terminals >Standard screwdriver |
|
Screw terminals >Tightening torque |
0.2 - 4 mm2 |
Screw terminals >Stripping length |
0.2 - 2.5 mm2
|
Display - Type |
0,2 - 2,5 mm2
|
Lines x characters |
22 - 12 AWG |
Operating ambient temperature |
0.8 x 3.5 mm |
Condensation |
0.5 - 0.7 Nm |
LCD display (clearly legible) |
6.5 mm |
Storage [ϑ] |
|
relative humidity |
Monochrome |
Air pressure (operation) |
6 x 16 |
Protection type (IEC/EN 60529, EN50178, VBG 4) |
|
Vibrations |
-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms |
Take appropriate measures to prevent condensation |
Drop to IEC/EN 60068-2-31 [Drop height] |
0 - 55 °C |
Free fall, packaged (IEC/EN 60068-2-32) |
-40 - +70 °C |
Mounting position |
in accordance with IEC 60068-2-30, IEC 60068-2-78 5 - 95 % |
Overvoltage category/pollution degree |
795 - 1080 hPa |
Electrostatic discharge (ESD) >applied standard |
|
Electrostatic discharge (ESD) >Air discharge |
IP20 |
Electrostatic discharge (ESD) >Contact discharge |
In accordance with IEC 60068-2-6 constant amplitude 0.15 mm: 10 - 57 constant acceleration 2 g: 57 - 150 Hz |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 |
18 Impacts |
Radio interference suppression |
50 mm |
Burst |
0.3 m |
power pulses (Surge) |
Vertical or horizontal |
Immunity to line-conducted interference to (IEC/EN 61000-4-6) |
|
Clearance in air and creepage distances |
III/2 |
Insulation resistance |
according to IEC EN 61000-4-2 |
Back-up of real-time clock |
8 kV |
Accuracy of real-time clock to inputs |
6 kV |
Accuracy of timing relays (of values) |
0.8 - 1.0 GHz: 10 1.4 - 2 GHz: 3 2.0 - 2.7 GHz: 1 V/m |
Resolution >Range “S” |
EN 61000-6-3 Class B |
Resolution >Range “M:S” |
according to IEC/EN 61000-4-4 Supply cables: 2 Signal cables: 2 kV |
Resolution >Range “H:M” |
according to IEC/EN 61000-4-5 1 kV (supply cables, symmetrical) 2 kV (supply cables, asymmetrical) |
Rated operational voltage [Ue] |
10 V |
Permissible range [Ue] |
|
Residual ripple |
nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Protection against polarity reversal |
per EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Frequency |
|
Voltage dips |
|
Fuse |
① Backup time (hours) with fully charged double layer capacitor ② Service life (years) |
Power loss [P] |
typ. ± 2 (± 0.2 h⁄Year) s/day |
Number |
depending on ambient air temperature fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible |
Status Display |
|
Potential isolation |
± 0.02 % |
Rated operational voltage [Ue] |
5 ms |
Input voltage [Ue] |
1 s |
Rated frequency |
1 min |
Input current at signal 1 |
|
Deceleration time |
100 - 240V DC (-15/+10%) 100 - 240 DC (cULus: 100 -110 DC) (-15/+10%) V |
Cable length |
85 - 264 V AC 85 - 264 V DC (cULus: 85 - 120 V DC) |
Number |
≦ 5 % |
Outputs in groups of |
yes |
Parallel switching of outputs for increased output |
50/60 (± 5%) Hz |
Protection of an output relay |
≤ 20 ms at 100V AC 10 ms at 100V DC ms |
Potential isolation |
≧ 1A (T) A |
Contacts >Conventional thermal current (10 A UL) |
Normally 10 W |
Contacts >Recommended for load: 12 V AC/DC |
|
Contacts >Rated impulse withstand voltage Uimp of contact coil |
8 |
Contacts >Rated operational voltage [Ue] |
LCD-Display |
Rated insulation voltage [Ui] |
from power supply: no for memory card: no for Ethernet interface: yes between inputs: no from the outputs: yes to the base unit: yes to the expansion units: yes |
Safe isolation according to EN 50178 |
100 - 240 V AC 100 - 240 V DC (cULus: 100 - 110 V DC) V |
Making capacity >AC–-15, 250 V AC, 3 A (600 ops./h) [Operations] |
Condition 0: 0 - 40V AC/DC Condition 1: 79–264 V AC/DC (cULus: 79–264 V AC/79–120 V DC) V |
Making capacity >DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] |
50/60 Hz |
Breaking capacity >AC-15, 250 V AC, 3 A (600 Ops./h) [Operations] |
I1 - I6: 6 x 0.25 (at 115 V AC, 60 Hz) I7, I8: 2 x 4 (at 115 V AC, 60 Hz) I1 - I6: 6 x 0.5 (at 230 V AC, 50 Hz) I7, I8: 2 x 6 (at 230 V AC, 50 Hz) I1 - I8: 8 x 0.25 (at 115V DC) I1 - I8: 8 x 0.5 (at 230V DC) mA |
Breaking capacity >DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] |
45/38 (0 -> 1/1 -> 0, debounce ON 50/60Hz) for AC type 25⁄21 (0 -> 1/1 -> 0, debounce OFF 50/60Hz) for AC 20 (0 -> 1/1 -> 0, debounce ON) for DC type 0.03 (0 -> 1/1 -> 0, debounce OFF) for DC ms |
Filament bulb load >1000 W at 230/240 V AC [Operations] |
40 (unshielded) (I1 - I6) 100 (unshielded) (I7, I8) m |
Filament bulb load >500 W at 115/120 V AC [Operations] |
|
Fluorescent lamp load >Fluorescent lamp load 10 x 58 W at 230/240 V AC >With upstream electrical device [Operations] |
4 |
Fluorescent lamp load >Fluorescent lamp load 10 x 58 W at 230/240 V AC >Uncompensated [Operations] |
1 |
Fluorescent lamp load >Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations] |
Not permitted |
Switching frequency >Mechanical operations |
B16 circuit breaker or 8 A (T) fuse |
Switching frequency >Switching frequency |
Safe isolation according to EN 50178: 300 V AC Basic isolation: 600 V AC from power supply: yes From the inputs: yes between outputs: yes to Ethernet: yes to control buttons: yes to expansion devices: yes |
Switching frequency >Resistive load/lamp load |
8 A |
Switching frequency >Inductive load |
> 500 mA |
UL/CSA >Uninterrupted current at 240 V AC |
6 kV |
UL/CSA >Uninterrupted current at 24 V DC |
240 V AC |
UL/CSA >AC >Control Circuit Rating Codes (utilization category) |
240 V AC |
UL/CSA >AC >Max. rated operational voltage |
300 between coil and contact 300 between two contacts V AC |
UL/CSA >AC >max. thermal continuous current cos ϕ = 1 at B 300 |
300000 |
UL/CSA >AC >max. make/break cos ϕ ≠ capacity 1 at B 300 |
200000 |
UL/CSA >DC >Control Circuit Rating Codes (utilization category) |
300000 |
UL/CSA >DC >Max. rated operational voltage |
200000 |
UL/CSA >DC >Max. thermal uninterrupted current at R 300 |
25000 |
UL/CSA >DC >Max. make/break capacity at R 300 |
25000 |
Power loss [P] |
25000 |
Data transfer rate |
25000 |
Connections |
25000 |
Cable |
10 x 106 |
Static heat dissipation, non-current-dependent [Pvs] |
10 Hz |
Operating ambient temperature min. |
2 Hz |
Operating ambient temperature max. |
0.5 Hz |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
10 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
8 A |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
B 300 Light Pilot Duty |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
300 V AC |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
5 A |
10.2 Strength of materials and parts >10.2.5 Lifting |
3600/360 VA |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
R 300 Light Pilot Duty |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
300 V DC |
10.3 Degree of protection of ASSEMBLIES |
1 A |
10.4 Clearances and creepage distances |
28/28 VA |
10.5 Protection against electric shock |
|
10.6 Incorporation of switching devices and components |
10 W |
10.7 Internal electrical circuits and connections |
|
10.8 Connections for external conductors |
10/100 Mbit/s |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
RJ45 plug, 8-pin |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
CAT5 |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
|
10.10 Temperature rise |
10 W |
10.11 Short-circuit rating |
-25 °C |
10.12 Electromagnetic compatibility |
+55 °C |
10.13 Mechanical function |
|
Supply voltage AC 50 Hz |
Meets the product standard´s requirements. |
Supply voltage AC 60 Hz |
Meets the product standard´s requirements. |
Supply voltage DC |
Meets the product standard´s requirements. |
Voltage type of supply voltage |
Meets the product standard´s requirements. |
Switching current |
Meets the product standard´s requirements. |
Number of analogue inputs |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of analogue outputs |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of digital inputs |
Meets the product standard´s requirements. |
Number of digital outputs |
Meets the product standard´s requirements. |
With relay output |
Meets the product standard´s requirements. |
Number of HW-interfaces industrial Ethernet |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of interfaces PROFINET |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of HW-interfaces RS-232 |
Is the panel builder´s responsibility. |
Number of HW-interfaces RS-422 |
Is the panel builder´s responsibility. |
Number of HW-interfaces RS-485 |
Is the panel builder´s responsibility. |
Number of HW-interfaces serial TTY |
Is the panel builder´s responsibility. |
Number of HW-interfaces USB |
Is the panel builder´s responsibility. |
Number of HW-interfaces parallel |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Number of HW-interfaces Wireless |
Is the panel builder´s responsibility. |
Number of HW-interfaces other |
Is the panel builder´s responsibility. |
With optical interface |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Supporting protocol for TCP/IP |
|
Supporting protocol for PROFIBUS |
|
Supporting protocol for CAN |
85 - 264 V |
Supporting protocol for INTERBUS |
85 - 264 V |
Supporting protocol for ASI |
85 - 264 V |
Supporting protocol for KNX |
AC/DC |
Supporting protocol for MODBUS |
8 A |
Supporting protocol for Data-Highway |
0 |
Supporting protocol for DeviceNet |
0 |
Supporting protocol for SUCONET |
8 |
Supporting protocol for LON |
4 |
Supporting protocol for PROFINET IO |
Yes |
Supporting protocol for PROFINET CBA |
1 |
Supporting protocol for SERCOS |
0 |
Supporting protocol for Foundation Fieldbus |
0 |
Supporting protocol for EtherNet/IP |
0 |
Supporting protocol for AS-Interface Safety at Work |
0 |
Supporting protocol for DeviceNet Safety |
0 |
Supporting protocol for INTERBUS-Safety |
0 |
Supporting protocol for PROFIsafe |
0 |
Supporting protocol for SafetyBUS p |
0 |
Supporting protocol for other bus systems |
1 |
Radio standard Bluetooth |
No |
Radio standard WLAN 802.11 |
Yes |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
IO link master |
No |
Redundancy |
No |
With display |
Yes |
Degree of protection (IP) |
No |
Basic device |
No |
Expandable |
No |
Expansion device |
No |
With timer |
No |
Rail mounting possible |
No |
Wall mounting/direct mounting |
No |
Front build in possible |
No |
Rack-assembly possible |
No |
Suitable for safety functions |
No |
Category according to EN 954-1 |
No |
SIL according to IEC 61508 |
No |
Performance level acc. EN ISO 13849-1 |
No |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Explosion safety category for gas |
No |
Explosion safety category for dust |
No |
Width |
No |
Height |
No |
Depth |
No |
UL File No. |
No |
UL Category Control No. |
No |
North America Certification |
Yes |
Degree of Protection |
IP20 |