alt
alt

EASY-E4-AC-16RE1
197222 EASY-E4-AC-16RE1
Y7-197222

I/O expansion, For use with easyE4, 100 - 240 V AC, 110 - 220 V DC (cULus: 100-110 V DC), Inputs expansion (number) digital: 8, screw terminalI/O expansion, Supply voltage: 100 - 240 V AC, 110 - 220 V DC. In cULus applications applies 100-110 VDC to all V DC Information. Can be used via easyConnect, Mounting position: Vertical or horizontal, Protection type (IEC/EN 60529, EN50178, VBG 4): IP20, Standards: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 60664, IEC 61131-2, EN 61010, EN 50178, cULus per UL 61010, CSA C22.2 No.61010

I/O expansion, For use with easyE4, 100 - 240 V AC, 110 - 220 V DC (cULus: 100-110 V DC), Inputs expansion (number) digital: 8, screw terminal
I/O expansion, Supply voltage: 100 - 240 V AC, 110 - 220 V DC. In cULus applications applies 100-110 VDC to all V DC Information. Can be used via easyConnect, Mounting position: Vertical or horizontal, Protection type (IEC/EN 60529, EN50178, VBG 4): IP20, Standards: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 60664, IEC 61131-2, EN 61010, EN 50178, cULus per UL 61010, CSA C22.2 No.61010

Product range Control relays easyE4
Subrange easyE4 digital input/output enhancements
Basic function easyE4 extensions
Description Input/output extension for easyE4 control relay
Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225)
Rated operating voltage 100 to 240 VAC or 100 to 240 VDC (cULus: 100 to 110 VDC)
Digital inputs: 8
Digital outputs: 8 relays
Screw terminals
Inputs expansion (number)
Display digital: 8
Software
Supply voltage with diagnostic LED
For use with EASYSOFT-SWLIC/easySoft 7
Standards 100 - 240 V AC, 100 - 240 V DC (cULus: 100 - 110 V DC)
Approvals
>Approvals
easyE4
Approvals
>certificate
Approvals
>shipping classification
EN 61000-6-2
EN 61000-6-3
IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-30
IEC 61131-2
EN 61010
EN 50178
Approvals cULus
Dimensions (W x H x D) CE
Weight DNV GL
Mounting 0000SPC-596
Connection type 71.5 x 90 x 58 mm
Screw terminals
>Solid
0.232 kg
Screw terminals
>flexible
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Screw terminals
>Solid or flexible conductor, with ferrule
screw terminal
Screw terminals
>Solid or stranded
Screw terminals
>Standard screwdriver
0.2 - 4 mm2
Screw terminals
>Tightening torque
0.2 - 2.5 mm2
Screw terminals
>Stripping length
0,2 - 2,5 mm2
Operating ambient temperature 22 - 12 AWG
Condensation 0.8 x 3.5 mm
Storage [ϑ] 0.5 - 0.7 Nm
relative humidity 6.5 mm
Air pressure (operation)
Protection type (IEC/EN 60529, EN50178, VBG 4) -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
Vibrations Take appropriate measures to prevent condensation
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms -40 - +70 °C
Drop to IEC/EN 60068-2-31 [Drop height] in accordance with IEC 60068-2-30, IEC 60068-2-78
5 - 95 %
Free fall, packaged (IEC/EN 60068-2-32) 795 - 1080 hPa
Mounting position
Overvoltage category/pollution degree IP20
Electrostatic discharge (ESD)
>applied standard
In accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 - 57
constant acceleration 2 g: 57 - 150 Hz
Electrostatic discharge (ESD)
>Air discharge
18 Impacts
Electrostatic discharge (ESD)
>Contact discharge
50 mm
Electromagnetic fields (RFI) to IEC EN 61000-4-3 0.3 m
Radio interference suppression Vertical or horizontal
Burst
power pulses (Surge) III/2
Immunity to line-conducted interference to (IEC/EN 61000-4-6) according to IEC EN 61000-4-2
Clearance in air and creepage distances 8 kV
Insulation resistance 6 kV
Rated operational voltage [Ue] 0.8 - 1.0 GHz: 10
1.4 - 2 GHz: 3
2.0 - 2.7 GHz: 1 V/m
Permissible range [Ue] EN 61000-6-3 Class B
Residual ripple according to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2 kV
Protection against polarity reversal according to IEC/EN 61000-4-5
1 kV (supply cables, symmetrical)
2 kV (supply cables, asymmetrical)
Frequency 10 V
Voltage dips
Fuse nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Power loss [P] in accordance with EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Number
Potential isolation 100 - 240V DC (-15/+10%)
100 - 240 DC (cULus: 100 -110 DC) (-15/+10%) V
Rated operational voltage [Ue] 85 - 264 V AC
85 - 264 V DC (cULus: 85 - 120 V DC)
Input voltage [Ue] ≦ 5 %
Rated frequency yes
Input current at signal 1 50/60 (± 5%) Hz
Deceleration time ≤ 20 ms at 100V AC
10 ms at 100V DC ms
Cable length ≧ 1A (T) A
Number Normally 11 W
Outputs in groups of
Parallel switching of outputs for increased output 8
Protection of an output relay from power supply: no
between inputs: no
from the outputs: yes
to the base unit: yes
to the expansion units: yes
Potential isolation 100 - 240 V AC
100 - 240 V DC (cULus: 100 - 110 V DC) V
Contacts
>Conventional thermal current (10 A UL)
Condition 0: 0 - 40V AC/DC
Condition 1: 79–264 V AC/DC (cULus: 79–264 V AC/79–120 V DC) V
Contacts
>Recommended for load: 12 V AC/DC
50/60 Hz
Contacts
>Rated impulse withstand voltage Uimp of contact coil
I1 - I8: 8 x 0.25 (at 115V AC, 60 Hz)
I1 - I8: 8 x 0.5 (at 230V AC, 50 Hz)
I1 - I8: 8 x 0.25 (at 115V DC)
I1 - I8: 8 x 0.5 (at 230V DC) mA
Contacts
>Rated operational voltage [Ue]
type 39⁄32 (0 - > 1/1 -> 0, 50/60Hz) in AC
type 0.5 (0 - > 1/1 -> 0) in DC ms
Rated insulation voltage [Ui] 40 (unshielded) m
Safe isolation according to EN 50178
Making capacity
>AC–-15, 250 V AC, 3 A (600 ops./h) [Operations]
8
Making capacity
>DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
1
Breaking capacity
>AC-15, 250 V AC, 3 A (600 Ops./h) [Operations]
Not permitted
Breaking capacity
>DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
B16 circuit breaker or 8 A (T) fuse
Filament bulb load
>1000 W at 230/240 V AC [Operations]
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
from power supply: yes
From the inputs: yes
between outputs: yes
to expansion devices: yes
Filament bulb load
>500 W at 115/120 V AC [Operations]
5 A
Fluorescent lamp load
>Fluorescent lamp load 10 x 58 W at 230/240 V AC
>With upstream electrical device [Operations]
> 500 mA
Fluorescent lamp load
>Fluorescent lamp load 10 x 58 W at 230/240 V AC
>Uncompensated [Operations]
6 kV
Fluorescent lamp load
>Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations]
240 V AC
Switching frequency
>Mechanical operations
240 V AC
Switching frequency
>Switching frequency
300 between coil and contact
300 between two contacts V AC
Switching frequency
>Resistive load/lamp load
300000
Switching frequency
>Inductive load
200000
UL/CSA
>Uninterrupted current at 240 V AC
300000
UL/CSA
>Uninterrupted current at 24 V DC
200000
UL/CSA
>AC
>Control Circuit Rating Codes (utilization category)
25000
UL/CSA
>AC
>Max. rated operational voltage
25000
UL/CSA
>AC
>max. thermal continuous current cos ϕ = 1 at B 300
25000
UL/CSA
>AC
>max. make/break cos ϕ ≠ capacity 1 at B 300
25000
UL/CSA
>DC
>Control Circuit Rating Codes (utilization category)
25000
UL/CSA
>DC
>Max. rated operational voltage
10 x 106
UL/CSA
>DC
>Max. thermal uninterrupted current at R 300
10 Hz
UL/CSA
>DC
>Max. make/break capacity at R 300
2 Hz
Power loss [P] 0.5 Hz
Static heat dissipation, non-current-dependent [Pvs] 5 A
Operating ambient temperature min. 5 A
Operating ambient temperature max. B 300 Light Pilot Duty
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
300 V AC
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
5 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
3600/360 VA
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
R 300 Light Pilot Duty
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
300 V DC
10.2 Strength of materials and parts
>10.2.5 Lifting
1 A
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
28/28 VA
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES 11 W
10.4 Clearances and creepage distances
10.5 Protection against electric shock 11 W
10.6 Incorporation of switching devices and components -25 °C
10.7 Internal electrical circuits and connections +55 °C
10.8 Connections for external conductors
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Supply voltage AC 50 Hz Meets the product standard´s requirements.
Supply voltage AC 60 Hz Meets the product standard´s requirements.
Supply voltage DC Meets the product standard´s requirements.
Voltage type of supply voltage Does not apply, since the entire switchgear needs to be evaluated.
Switching current Does not apply, since the entire switchgear needs to be evaluated.
Number of analogue inputs Is the panel builder´s responsibility.
Number of analogue outputs Is the panel builder´s responsibility.
Number of digital inputs Is the panel builder´s responsibility.
Number of digital outputs Is the panel builder´s responsibility.
With relay output Is the panel builder´s responsibility.
Number of HW-interfaces industrial Ethernet The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of interfaces PROFINET Is the panel builder´s responsibility.
Number of HW-interfaces RS-232 Is the panel builder´s responsibility.
Number of HW-interfaces RS-422 The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of HW-interfaces RS-485
Number of HW-interfaces serial TTY
Number of HW-interfaces USB 85 - 264 V
Number of HW-interfaces parallel 85 - 264 V
Number of HW-interfaces Wireless 85 - 264 V
Number of HW-interfaces other AC/DC
With optical interface 5 A
Supporting protocol for TCP/IP 0
Supporting protocol for PROFIBUS 0
Supporting protocol for CAN 8
Supporting protocol for INTERBUS 8
Supporting protocol for ASI Yes
Supporting protocol for KNX 0
Supporting protocol for MODBUS 0
Supporting protocol for Data-Highway 0
Supporting protocol for DeviceNet 0
Supporting protocol for SUCONET 0
Supporting protocol for LON 0
Supporting protocol for PROFINET IO 0
Supporting protocol for PROFINET CBA 0
Supporting protocol for SERCOS 0
Supporting protocol for Foundation Fieldbus 2
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth No
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
IO link master No
Redundancy No
With display No
Degree of protection (IP) No
Basic device No
Expandable No
Expansion device No
With timer No
Rail mounting possible No
Wall mounting/direct mounting No
Front build in possible No
Rack-assembly possible No
Suitable for safety functions No
Category according to EN 954-1 No
SIL according to IEC 61508 No
Performance level acc. EN ISO 13849-1 No
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Explosion safety category for gas No
Explosion safety category for dust IP20
Width No
Height Yes
Depth Yes
UL File No. No
UL Category Control No. Yes
North America Certification Yes
Degree of Protection No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

EASY-NT-RJ45
Eaton
EASY-E4-UC-12RC1
Eaton
EASY-E4-UC-12RCX1
Eaton
EASY-E4-DC-12TC1
Eaton
EASY-E4-DC-12TCX1
Eaton
EASY-E4-AC-12RC1
Eaton
EASY-E4-AC-12RCX1
Eaton
EASY-E4-UC-8RE1
Eaton