Overload relay, Separate mounting, Earth-fault protection: none, Ir= 0.33 - 1.65 A, 1 N/O, 1 N/COverload relay, Product range: Electronic overload relays ZEB, Phase-failure sensitivity: IEC/EN 60947, VDE 0660 Part 102, Description: Test/off button, Reset pushbutton, Manual/auto reset selectable, Protection with heavy starting duty (Class 10A-30), Mounting type: Separate mounting, Auxiliary contacts N/O = Normally open: 1 N/O, Auxiliary contacts N/C = Normally closed: 1 N/C, For use with: DILM17, DILM25, DILM32, DILM38, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP20

Overload relay, Separate mounting, Earth-fault protection: none, Ir= 0.33 - 1.65 A, 1 N/O, 1 N/C
Overload relay, Product range: Electronic overload relays ZEB, Phase-failure sensitivity: IEC/EN 60947, VDE 0660 Part 102, Description: Test/off button, Reset pushbutton, Manual/auto reset selectable, Protection with heavy starting duty (Class 10A-30), Mounting type: Separate mounting, Auxiliary contacts N/O = Normally open: 1 N/O, Auxiliary contacts N/C = Normally closed: 1 N/C, For use with: DILM17, DILM25, DILM32, DILM38, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP20

Product range Electronic overload relays ZEB
Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102
Description Test/off button
Reset pushbutton
Manual/auto reset selectable
Protection with heavy starting duty (Class 10A-30)
Mounting type Separate mounting
Earth-fault protection
Overload releases [Ir ] none
Contact sequence
N/O = Normally open 0.33 - 1.65 A
N/C = Normally closed 230S005
For use with
Explosion protection (according to ATEX 94/9/EC) 1 N/O
EC-prototype test certification 1 N/C
Standards DILM17
DILM25
DILM32
DILM38
DIULM17
DIULM25
DIULM32
SDAINLM30
SDAINLM45
SDAINLM55
Climatic proofing
Ambient temperature
>Open
II(2)GD [Ex d] [Ex e] [Ex tb]
Ambient temperature
>Ambient temperature open max.
SIRA 13 ATEX 9348X
Ambient temperature
>Enclosed
>Ambient temperature enclosed max.
Mechanical shock resistance IEC/EN 60947, VDE 0660, UL, CSA
Degree of Protection Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Protection against direct contact when actuated from front (EN 50274) -25 - +65 °C
Altitude 65 °C
Rated impulse withstand voltage [Uimp] 65 °C
Overvoltage category/pollution degree 15
Shock duration 10 ms
according to IEC 60068-2-27 g
Rated insulation voltage [Ui ] IP20
Rated operational voltage [Ue] Finger and back-of-hand proof
Rated frequency [f] Max. 2000 m
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
Safe isolation to EN 61140
>Between main circuits
6000 V AC
Terminal capacities
>Solid
III/3
Terminal capacities
>Solid or stranded
690 V AC
Stripping length 690 V AC
Rated impulse withstand voltage [Uimp] 50/60 Hz
Overvoltage category/pollution degree 600 V AC
Terminal capacities
>Solid
600 V AC
Terminal capacities
>Flexible with ferrule
1 x 1.5 - 16 mm2
Terminal capacities
>Solid or stranded
1 x 14 - 4 AWG
Terminal screw 13 mm
Tightening torque
Tightening torque 6000 V
Stripping length III/3
Tools
>Pozidriv screwdriver
2 x (0.75 - 4) mm2
Tools
>Standard screwdriver
2 x (0.75 - 2.5) mm2
Rated insulation voltage [Ui ] 2 x (18 - 12) AWG
Rated operational voltage [Ue ] M3.5
Safe isolation to EN 61140
>between the auxiliary contacts
0.8 - 1.2 Nm
Conventional thermal current [Ith ] 7 lb-in
Rated operational current [Ie ]
>AC-15
>Make contact
>120 V [Ie ]
8 mm
Rated operational current [Ie ]
>AC-15
>Make contact
>220 V 230 V 240 V [Ie ]
2 Size
Rated operational current [Ie ]
>AC-15
>Make contact
>380 V 400 V 415 V [Ie ]
1 x 6 mm
Rated operational current [Ie ]
>AC-15
>Make contact
>500 V [Ie ]
500 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>120 V [Ie ]
500 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>220 V 230 V 240 V [Ie ]
240 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>380 V 400 V 415 V [Ie ]
5 A
Rated operational current [Ie ]
>AC-15
>Break contact
>500 V [Ie ]
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>24 V [Ie ]
0.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>60 V [Ie ]
0.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>110 V [Ie ]
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>220 V [Ie ]
1.5 A
Short-circuit rating without welding
>max. fuse
0.9 A
Auxiliary contacts
>Pilot Duty
>AC operated
0.8 A
Auxiliary contacts
>Pilot Duty
>DC operated
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Short Circuit Current Rating
>Basic Rating
>SCCR
0.9 A
Short Circuit Current Rating
>Basic Rating
>max. Fuse
0.75 A
Rated operational current for specified heat dissipation [In] 0.4 A
Heat dissipation per pole, current-dependent [Pvid] 0.2 A
Equipment heat dissipation, current-dependent [Pvid] 6 A gG/gL
Static heat dissipation, non-current-dependent [Pvs]
Heat dissipation capacity [Pdiss] B600
Operating ambient temperature min. R300
Operating ambient temperature max. 1 kA
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
6, RK5 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
1.65 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0.17 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0.5 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
-25 °C
10.3 Degree of protection of ASSEMBLIES +65 °C
10.4 Clearances and creepage distances
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Adjustable current range Does not apply, since the entire switchgear needs to be evaluated.
Mounting method Is the panel builder´s responsibility.
Type of electrical connection of main circuit Is the panel builder´s responsibility.
Number of auxiliary contacts as normally closed contact Is the panel builder´s responsibility.
Number of auxiliary contacts as normally open contact Is the panel builder´s responsibility.
Number of auxiliary contacts as change-over contact Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 50HZ The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated control supply voltage Us at DC Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Release class The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Voltage type for actuating
Reset function automatic
Reset function input 0.33 - 1.65 A
Reset function push-button Separate positioning
Product Standards Screw connection
UL File No. 1
UL Category Control No. 1
CSA File No. 0
CSA Class No. 0 - 0 V
North America Certification 0 - 0 V
Specially designed for North America 0 - 0 V
Suitable for Adjustable
Max. Voltage Rating Self powered
Degree of Protection Yes
Characteristic curve No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.