alt
alt

ZEB225-175
164307 ZEB225-175
164307

Overload relay, Direct mounting, Earth-fault protection: none, Ir= 35 - 175 A, 1 N/O, 1 N/COverload relay, Product range: Electronic overload relays ZEB, Phase-failure sensitivity: IEC/EN 60947, VDE 0660 Part 102, Description: Test/off button, Reset pushbutton, Manual/auto reset selectable, Protection with heavy starting duty (Class 10A-30), Mounting type: Direct mounting, Auxiliary contacts N/O = Normally open: 1 N/O, Auxiliary contacts N/C = Normally closed: 1 N/C, For use with: DILM185A, DILM225A, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP00

Overload relay, Direct mounting, Earth-fault protection: none, Ir= 35 - 175 A, 1 N/O, 1 N/C
Overload relay, Product range: Electronic overload relays ZEB, Phase-failure sensitivity: IEC/EN 60947, VDE 0660 Part 102, Description: Test/off button, Reset pushbutton, Manual/auto reset selectable, Protection with heavy starting duty (Class 10A-30), Mounting type: Direct mounting, Auxiliary contacts N/O = Normally open: 1 N/O, Auxiliary contacts N/C = Normally closed: 1 N/C, For use with: DILM185A, DILM225A, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP00

Product range Electronic overload relays ZEB
Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102
Description Test/off button
Reset pushbutton
Manual/auto reset selectable
Protection with heavy starting duty (Class 10A-30)
Mounting type Direct mounting
Earth-fault protection
Overload releases [Ir ] none
Contact sequence
N/O = Normally open 35 - 175 A
N/C = Normally closed 230S002
For use with
Standards 1 N/O
Climatic proofing 1 N/C
Ambient temperature
>Open
DILM185A
DILM225A
Ambient temperature
>Ambient temperature open max.
Ambient temperature
>Enclosed
>Ambient temperature enclosed max.
IEC/EN 60947, VDE 0660, UL, CSA
Mechanical shock resistance Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Degree of Protection -25 - +65 °C
Protection against direct contact when actuated from front (EN 50274) 65 °C
Altitude 45 °C
Rated impulse withstand voltage [Uimp] 15
Shock duration 10 ms
according to IEC 60068-2-27 g
Overvoltage category/pollution degree IP00
Rated insulation voltage [Ui ] With terminal cover
Rated operational voltage [Ue] Max. 2000 m
Rated frequency [f]
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
6000 V AC
Safe isolation to EN 61140
>Between main circuits
III/3
Terminal capacities
>Solid
690 V AC
Terminal capacities
>Solid or stranded
690 V AC
Terminal capacities
>Flat conductor [Lamellenzahl x Breite x Dicke ]
50/60 Hz
Stripping length 600 V AC
Rated impulse withstand voltage [Uimp] 600 V AC
Overvoltage category/pollution degree 1 x 10 - 95 mm2
Terminal capacities
>Solid
1 x 8 - 4/0 AWG
Terminal capacities
>Flexible with ferrule
6 x 18 x 0.8 mm
Terminal capacities
>Solid or stranded
22 mm
Terminal screw
Tightening torque 6000 V
Tightening torque III/3
Stripping length 2 x (0.75 - 4) mm2
Tools
>Pozidriv screwdriver
2 x (0.75 - 2.5) mm2
Tools
>Standard screwdriver
2 x (18 - 12) AWG
Rated insulation voltage [Ui ] M3.5
Rated operational voltage [Ue ] 0.8 - 1.2 Nm
Safe isolation to EN 61140
>between the auxiliary contacts
7 lb-in
Conventional thermal current [Ith ] 8 mm
Rated operational current [Ie ]
>AC-15
>Make contact
>120 V [Ie ]
2 Size
Rated operational current [Ie ]
>AC-15
>Make contact
>220 V 230 V 240 V [Ie ]
1 x 6 mm
Rated operational current [Ie ]
>AC-15
>Make contact
>380 V 400 V 415 V [Ie ]
500 V AC
Rated operational current [Ie ]
>AC-15
>Make contact
>500 V [Ie ]
500 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>120 V [Ie ]
240 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>220 V 230 V 240 V [Ie ]
5 A
Rated operational current [Ie ]
>AC-15
>Break contact
>380 V 400 V 415 V [Ie ]
1.5 A
Rated operational current [Ie ]
>AC-15
>Break contact
>500 V [Ie ]
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
0.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>24 V [Ie ]
0.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>60 V [Ie ]
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>110 V [Ie ]
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>220 V [Ie ]
0.9 A
Short-circuit rating without welding
>max. fuse
0.8 A
Auxiliary contacts
>Pilot Duty
>AC operated
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Auxiliary contacts
>Pilot Duty
>DC operated
0.9 A
Short Circuit Current Rating
>600 V High Fault
>SCCR (fuse)
0.75 A
Short Circuit Current Rating
>600 V High Fault
>max. Fuse
0.4 A
Rated operational current for specified heat dissipation [In] 0.2 A
Heat dissipation per pole, current-dependent [Pvid] 6 A gG/gL
Equipment heat dissipation, current-dependent [Pvid]
Static heat dissipation, non-current-dependent [Pvs] B600
Heat dissipation capacity [Pdiss] R300
Operating ambient temperature min. 100 kA
Operating ambient temperature max. 400 Class J A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
175 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
11.86 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
35.6 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
-25 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
+65 °C
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Adjustable current range Is the panel builder´s responsibility.
Mounting method Is the panel builder´s responsibility.
Type of electrical connection of main circuit Is the panel builder´s responsibility.
Number of auxiliary contacts as normally closed contact Is the panel builder´s responsibility.
Number of auxiliary contacts as normally open contact Is the panel builder´s responsibility.
Number of auxiliary contacts as change-over contact The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated control supply voltage Us at AC 50HZ Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated control supply voltage Us at DC The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Release class
Voltage type for actuating
Reset function automatic 0 - 175 A
Reset function input Direct attachment
Reset function push-button Screw connection
Product Standards 1
UL File No. 1
UL Category Control No. 0
CSA File No. 0 - 0 V
CSA Class No. 0 - 0 V
North America Certification 0 - 0 V
Specially designed for North America Adjustable
Suitable for Self powered
Max. Voltage Rating Yes
Degree of Protection No
Characteristic curve Yes

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.