Accessories |
Filtering: |
Description |
Interference suppression of the external 24 V DC supply of the XC100/200 |
Max. current consumption |
2.2 A |
Information relevant for export to North America |
Product Standards IEC: see Technical Data; UL508; CSA-C22.2 No. 0-M; CSA-C22.2 No. 142-M; CE marking UL File No. E135462 UL Category Control No. NRAQ CSA File No. 012528 CSA Class No. 2252-01 North America Certification UL listed, CSA certified Degree of Protection IEC: IP20, UL/CSA Type: - |
Standards |
|
Ambient temperature |
IEC/EN 61131-2 EN 50178 |
Storage [ϑ] |
0 - +55 °C |
Mounting position |
-25 - +70 °C |
Vibration resistance |
Vertical or horizontal |
Mechanical shock resistance |
10 - 57 Hz ± 0.075 mm 57 - 150 Hz ± 1.0 g |
Impact resistance |
15 Shock duration 11 ms g |
Overvoltage category/pollution degree |
500 g/⌀ 50 mm ±25 g |
Degree of Protection |
II/2 |
Rated impulse withstand voltage [Uimp] |
IP20 |
Emitted interference |
850 V |
Interference immunity |
DIN/EN 55011/22, Class A |
Weight |
EN 50081-2 |
Dimensions (W x H x D) |
0.095 kg |
Terminations |
35 x 90 x 30 mm |
Terminal capacities >Screw terminals >Flexible with ferrule |
Screw terminals |
Terminal capacities >Screw terminals >Solid |
0.2 - 2.5 (AWG22 - 12) mm2 |
Input voltage |
0.2 - 2.5 (AWG22 - 12) mm2 |
Admissible range |
|
Residual ripple |
24 V DC |
Mains overvoltage protection |
20.4 - 28.8 V DC |
Potential isolation >Input voltage against PE |
≦ 5 % |
Potential isolation >Input voltage agaisnt output voltage |
Yes |
Potential isolation >Output voltage against PE |
Yes |
Rated value |
No |
Output current |
Yes |
Rated operational current for specified heat dissipation [In] |
24 V DC |
Heat dissipation per pole, current-dependent [Pvid] |
2.2 A |
Equipment heat dissipation, current-dependent [Pvid] |
|
Static heat dissipation, non-current-dependent [Pvs] |
0 A |
Heat dissipation capacity [Pdiss] |
0 W |
Operating ambient temperature min. |
0 W |
Operating ambient temperature max. |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
+55 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
|
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Type of electrical accessory |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Type of mechanical accessory |
Is the panel builder´s responsibility. |
Product Standards |
Is the panel builder´s responsibility. |
UL File No. |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
UL Category Control No. |
|
CSA File No. |
|
CSA Class No. |
Other |
North America Certification |
Other |
Specially designed for North America |
IEC: see Technical Data; UL508; CSA-C22.2 No. 0-M; CSA-C22.2 No. 142-M; CE marking |
Current Limiting Circuit-Breaker |
E135462 |
Degree of Protection |
NRAQ |