ECO gateway for XI/ON I/O system, modbus-TCPThe XI/ON standard I/O system adds cost and space-optimized I/O modules and gateways to the XI/ON I/O system. The ECO modules do not need base modules and are fully compatible with the standard XI/ON system. High channel density (up to 16 DI/DO on 13 mm), push-in spring-cage terminals, 8 or 16 channels per module. The ECO gateways support the CANopen bus systems Profibus DP and Ethernet.
ECO gateway for XI/ON I/O system, modbus-TCP
The XI/ON standard I/O system adds cost and space-optimized I/O modules and gateways to the XI/ON I/O system. The ECO modules do not need base modules and are fully compatible with the standard XI/ON system. High channel density (up to 16 DI/DO on 13 mm), push-in spring-cage terminals, 8 or 16 channels per module. The ECO gateways support the CANopen bus systems Profibus DP and Ethernet.
Function | XI/ON ECO gateways |
Connection technique | Push-in spring-cage terminal |
Field bus connection | Ethernet (Modbus-TCP protocol) |
Data transfer rate | 10/100 MBit/s |
Information about equipment supplied | The delivery package for all gateways includes: 2 x end bracket XN-WEW-32/2-SW, 1 x end plate XN-ABPL |
Approvals >Approvals |
|
Operating ambient temperature min. | CE, cULus EAC |
Operating ambient temperature max. | 0 °C |
Static heat dissipation, non-current-dependent [Pvs] | +55 °C |
Other technical data (sheet catalogue) | 8 W |
Connection design in TOP direction | Technical Data |
System supply [Usys ] | |
Connection design for field bus | Push-In spring-cage terminals |
Addressing | |
Rated operational current for specified heat dissipation [In] | 24 /5 V DC |
Heat dissipation per pole, current-dependent [Pvid] | 2 x RJ45 (Ethernet Switch) |
Equipment heat dissipation, current-dependent [Pvid] | DIP switch, BootP, DHCP or PGM |
Static heat dissipation, non-current-dependent [Pvs] | |
Heat dissipation capacity [Pdiss] | 0 A |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 W |
Degree of Protection | 8 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
+55 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
IP20 |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
|
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
Supply voltage AC 50 Hz | Is the panel builder´s responsibility. |
Supply voltage AC 60 Hz | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Supply voltage DC | Is the panel builder´s responsibility. |
Voltage type of supply voltage | Is the panel builder´s responsibility. |
Supporting protocol for TCP/IP | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Supporting protocol for PROFIBUS | |
Supporting protocol for CAN | |
Supporting protocol for INTERBUS | 0 - 0 V |
Supporting protocol for ASI | 0 - 0 V |
Supporting protocol for KNX | 18 - 30 V |
Supporting protocol for MODBUS | DC |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for SERCOS | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | Yes |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
IO link master | No |
System accessory | No |
Degree of protection (IP) | No |
With potential separation | No |
Fieldbus connection over separate bus coupler possible | No |
Rail mounting possible | No |
Wall mounting/direct mounting | No |
Front build in possible | No |
Rack-assembly possible | Yes |
Suitable for safety functions | IP20 |
Category according to EN 954-1 | Yes |
SIL according to IEC 61508 | Yes |
Performance level acc. EN ISO 13849-1 | Yes |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Explosion safety category for gas | No |
Explosion safety category for dust | No |
Width | |
Height | None |
Depth | None |
Link to sheet catalogue | No |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.