Power supply module XI/ON, 120/230VACPower supply module, Function: XN Slice module, For use with: XN-P3T-SBB, XN-P3S-SBB, XN-P4T-SBBC, XN-P4S-SBBC, Standards: EN 61000-6-2, EN 61000-6-4, EN 61131-2, Degree of Protection: IP20
Power supply module XI/ON, 120/230VAC
Power supply module, Function: XN Slice module, For use with: XN-P3T-SBB, XN-P3S-SBB, XN-P4T-SBBC, XN-P4S-SBBC, Standards: EN 61000-6-2, EN 61000-6-4, EN 61131-2, Degree of Protection: IP20
Function | XI/ON power supply modules |
Function | XN Slice module |
Short Description | Field power supply module with 120/230 V AC nominal voltage |
For use with | XN-P3T-SBB XN-P3S-SBB XN-P4T-SBBC XN-P4S-SBBC |
Standards | |
Potential isolation | EN 61000-6-2 EN 61000-6-4 EN 61131-2 |
Ambient temperature | Yes, through optocoupler |
Storage [ϑ] | 0 - +55 °C |
Relative humidity | -25 - +85 °C |
Harmful gases | 5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C) |
Vibration resistance, operating conditions | SO2: 10 (rel. humidity < 75%, no condensation) H2S: 1.0 (rel. humidity < 75 %,no condensation) ppm |
Mechanical shock resistance | according to IEC/EN 60068-2-6 |
Continuous shock resistance (IEC/EN 60068-2-29) | according to IEC 60068-2-27 g |
Drop and topple | According to IEC 60068-2-29 |
Degree of Protection | According to IEC 60068-2-31, free fall according to IEC 60068-2-32 |
Electromagnetic compatibility (EMC) >ESD [Air/contact discharge] |
IP20 |
Electromagnetic compatibility (EMC) >Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ] |
EN 61000-4-2 kV |
Electromagnetic compatibility (EMC) >Burst |
EN 61100-4-2 V/m |
Electromagnetic compatibility (EMC) >Surge |
EN 61100-4-4 |
Electromagnetic compatibility (EMC) >Radiated RFI |
EN 61100-4-5 |
Electromagnetic compatibility (EMC) >Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)] |
EN 61100-4-6 V |
Electromagnetic compatibility (EMC) >Voltage fluctuations/voltage dips |
EN 55016-2-3 dB |
Electromagnetic compatibility (EMC) >Type test |
EN 61131-2 |
Approvals | to EN 61131-2 |
Other technical data (sheet catalogue) | CE, cULus |
Coordination type "2" [Usys] >Max. addmissible range |
Technical Data |
Field voltage [UL ] | |
Admissible range | 4 V DC |
Rated current consumption from module bus [IMB ] | 120/230 V AC |
Rated insulation voltage [Ui] | 102 - 132 V AC (120 V AC) 195.5 - 253 V AC (230 V AC) |
Residual ripple | ≦ 25 mA |
Maximum operating current [IEI ] | 1500 V AC |
Number of diagnostic bytes | According to EN 61131-2; ripple < 5 % |
Base module without gateway power supply >without C connection |
10 A |
Base module without gateway power supply >with C connection |
4 |
Power loss [P] | 2-/3-wire XN-P3x-SBB |
Rated operational current for specified heat dissipation [In] | 4-wire XN-P4x-SBBC |
Heat dissipation per pole, current-dependent [Pvid] | 1.3 W |
Equipment heat dissipation, current-dependent [Pvid] | |
Static heat dissipation, non-current-dependent [Pvs] | Permissible range for nominal voltage and field voltage UL: to EN 61131-2 |
Heat dissipation capacity [Pdiss] | |
Operating ambient temperature min. | 0 A |
Operating ambient temperature max. | 0 W |
Degree of Protection | 0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
1.3 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
+55 °C |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
IP20 |
10.2 Strength of materials and parts >10.2.5 Lifting |
|
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise | Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
Supply voltage AC 50 Hz | Is the panel builder´s responsibility. |
Supply voltage AC 60 Hz | Is the panel builder´s responsibility. |
Supply voltage DC | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Voltage type of supply voltage | Is the panel builder´s responsibility. |
Number of HW-interfaces industrial Ethernet | Is the panel builder´s responsibility. |
Number of interfaces PROFINET | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of HW-interfaces RS-232 | |
Number of HW-interfaces RS-422 | |
Number of HW-interfaces RS-485 | 0 - 0 V |
Number of HW-interfaces serial TTY | 0 - 0 V |
Number of HW-interfaces parallel | 18 - 30 V |
Number of HW-interfaces Wireless | DC |
Number of HW-interfaces USB | 0 |
Number of HW-interfaces other | 0 |
With optical interface | 0 |
Supporting protocol for TCP/IP | 0 |
Supporting protocol for PROFIBUS | 0 |
Supporting protocol for CAN | 0 |
Supporting protocol for INTERBUS | 0 |
Supporting protocol for ASI | 0 |
Supporting protocol for KNX | 0 |
Supporting protocol for MODBUS | 1 |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for SERCOS | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
System accessory | No |
Degree of protection (IP) | No |
Type of electric connection | Yes |
With potential separation | No |
With power supply module | No |
Suitable as segment module | No |
Remote module | No |
Fieldbus connection over separate bus coupler possible | No |
Bus diagnosis possible | Yes |
Rail mounting possible | IP20 |
Wall mounting/direct mounting | Screw-/spring clamp connection |
Front build in possible | Yes |
Rack-assembly possible | No |
Suitable for safety functions | Yes |
Category according to EN 954-1 | No |
SIL according to IEC 61508 | Yes |
Performance level acc. EN ISO 13849-1 | Yes |
Appendant operation agent (Ex ia) | Yes |
Appendant operation agent (Ex ib) | No |
Explosion safety category for gas | No |
Explosion safety category for dust | No |
Width | No |
Height | |
Depth | None |
Product Standards | None |
UL File No. | No |
UL Category Control No. | No |
CSA File No. | None |
CSA Class No. | None |
North America Certification | 12.6 mm |
Specially designed for North America | 74.1 mm |
Current Limiting Circuit-Breaker | 55.4 mm |
Degree of Protection | UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking |
Link to sheet catalogue | E205091 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.