Digital I/O module, 4 digital inputs and 4 digital outputs 24 V DC each, pulse-switchingDigital I/O module with four 24 V DC / 3.7 mA (EN61131-2 type 1) inputs with a 0.5 ms input filter. Digital I/O module with four 24 V DC / 0.5 A short-circuit proof outputs, featuring undervoltage diagnostics for the power supply rails

Digital I/O module, 4 digital inputs and 4 digital outputs 24 V DC each, pulse-switching
Digital I/O module with four 24 V DC / 3.7 mA (EN61131-2 type 1) inputs with a 0.5 ms input filter. Digital I/O module with four 24 V DC / 0.5 A short-circuit proof outputs, featuring undervoltage diagnostics for the power supply rails

Function XN300 I/O slice modules
Connection technique Push-in spring-cage terminal
Function XN-322 digital input and output module for XN300
Short Description 4 digital inputs and 4 digital outputs 24 V DC each, pulse-switching
For use with XN-312-…
XC-303-...
Standards
Approvals
>Approvals
IEC/EN 61131-2
IEC/EN 61000-6-2
IEC/EN 61000-6-4
Approvals
>shipping classification
CE, cULus
EAC
Approvals DNV GL
Electromagnetic compatibility (EMC)
>ESD [Air/contact discharge]
0000SPC-637
Electromagnetic compatibility (EMC)
>Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ]
8 / 4 kV
Electromagnetic compatibility (EMC)
>Burst
>Supply cable
10 / 3 / 1 V/m
Electromagnetic compatibility (EMC)
>Burst
>Signal cable
2 kV
Electromagnetic compatibility (EMC)
>Surge
>Supply cable (balanced / unbalanced)
1 kV
Electromagnetic compatibility (EMC)
>Surge
>Signal cable (unbalanced)
0,5 / 0,5 kV
Electromagnetic compatibility (EMC)
>Radiated RFI
1 kV
Electromagnetic compatibility (EMC)
>Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)]
10 V
Electromagnetic compatibility (EMC)
>Voltage fluctuations/voltage dips
40 / 47 class A dB
Ambient conditions
>Climatic conditions
>Climatic proofing
Yes / 10 ms
Ambient conditions
>Climatic conditions
>Air pressure (operation)
Dry heat to IEC 60068-2-2
Damp heat as per EN 60068-2-3
Ambient conditions
>Climatic conditions
>Relative humidity
795 - 1080 hPa
Ambient conditions
>Climatic conditions
>Condensation
0 - 95%, non condensing
Ambient conditions
>Temperature
>Operation
prevent with suitable measures
Ambient conditions
>Temperature
>Storage, transport [ϑ]
0 - +60 °C
Degree of Protection -20 - +85 °C
Mounting position IP20
Free fall, packaged (IEC/EN 60068-2-32) Vertical (on horizontal top-hat rail)
Vibrations [3,5 mm / 1 g] 1 m
Mechanical shock resistance [Semisinusoidal 15 g/11 ms] 5 - 8.4 / 8.4 -150 Hz
Rated operational data
>Insulating material group
18 Impacts
Rated operational data
>Overvoltage category / pollution degree
Rated operational data
>Rated operating voltage
I
Rated operational data
>Maximum load current/cross-sectional area
III / 3
Connection design in TOP direction 160 V
Stripping length X (not specified by plug manufacturer) A / mm²
Gauge pin IEC/EN 60947-1 Push-in spring-cage terminal (plug-in connection)
Connection specifications
>"e" solid H07V-U
10 mm
Connection specifications
>"f" flexible H 07V-K
A1
Connection specifications
>"f" with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm2
Connection specifications
>"f" with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm2
Connection specifications
>Cable size
0.25 - 1.5 mm2
Power supply - Input
>Power supply
>Current consumption for +5 V power supply (internal) [I]
0.25-1,5 mm2
Power supply - Input
>Power supply
>Current consumption for +24 V power supply [I]
24 - 16 AWG
Power supply - Input
>Power supply
>Potential isolation [PE (polyethylene)]
Power supply - Input
>Power supply
>Rated operating voltage [Ue]
(typ.)45 mA
Power supply - Input
>Power supply
>Rated operational current [Ie]
(typ.)none mA
Power supply - Input
>Power supply
>Potential isolation
no
Heat dissipation
>Heat dissipation (without active channels)
24 (terminal +1) V
Heat dissipation
>Max. heat dissipation
2 A
Heat dissipation
>Notes on heat dissipation
no
Channels 0.25 W
Input voltage
>Nominal input voltage [Ue]
1.502 W
Input voltage
>Low level [UeL]
The max. heat dissipation is specified as the maximum power produced inside the device´s housing.
Input voltage
>High level [UeH]
Input current
>Input current, nominal value [Ie]
4 Number
Input current
>Low level⁄active level [IeL]
24 V DC
Input current
>High level⁄active level [IeH]
0 < UeL < +8 V
Input delay
>tRising edge
+14 < UeH < +30 V
Input delay
>tFalling edge
3.7 mA
Potential isolation ≤1.1 mA
Heat dissipation (per active channel) ≥2.3 mA
Notes on digital inputs < 5000 µs
Channels < 5000 µs
Output voltage
>Output voltage, nominal value [Ua]
no Input to input
Output voltage
>Low level [UaL]
0.088 W
Output voltage
>High level [UaH]
Output current
>Output current, nominal value [IaL]
Inputs as per EN61131-2 Type 1
Output current
>Low signal [IA ]
Output current
>High level [IaH]
4 Quantity
Short-circuit rating 24 V DC
Potential isolation 0V < UaL < 1V V
Heat dissipation (internal, per active channel) Ue - 1V < UaH < Ue V
Utilization factor [%] 0.5 A
Delay on signal change and resistive load
>from Low to High level
0 < IaL < 0.5 mA
Delay on signal change and resistive load
>From High to Low signal
0 ≤ IaH ≤ 500 mA
Resistive load
>Resistive load
Yes
Notes on digital outputs no Output against output
Static heat dissipation, non-current-dependent [Pvs] 0.095 W
Operating ambient temperature min. 100% (Ʃ IAmax = 2A) g
Operating ambient temperature max. < 100 µs
Degree of Protection < 150 µs
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
> 48 Ω
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Protective devices must be installed directly at the inductive load in order to prevent interference.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
1.502 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 °C
10.2 Strength of materials and parts
>10.2.5 Lifting
+55 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
IP20
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Is the panel builder´s responsibility.
Supply voltage AC 50 Hz Is the panel builder´s responsibility.
Supply voltage AC 60 Hz Is the panel builder´s responsibility.
Supply voltage DC Is the panel builder´s responsibility.
Voltage type of supply voltage Is the panel builder´s responsibility.
Number of digital inputs The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of digital outputs Is the panel builder´s responsibility.
Digital inputs configurable Is the panel builder´s responsibility.
Digital outputs configurable The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Input current at signal 1
Permitted voltage at input
Type of voltage (input voltage) 0 - 0 V
Type of digital output 0 - 0 V
Output current 18 - 30 V
Permitted voltage at output DC
Type of output voltage 4
Short-circuit protection, outputs available 4
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET No
Number of HW-interfaces RS-232 2.3 mA
Number of HW-interfaces RS-422 30 - 30 V
Number of HW-interfaces RS-485 DC
Number of HW-interfaces serial TTY None
Number of HW-interfaces parallel 0.5 A
Number of HW-interfaces Wireless 0 - 30 V
Number of HW-interfaces USB DC
Number of HW-interfaces other No
With optical interface 0
Supporting protocol for TCP/IP 0
Supporting protocol for PROFIBUS 0
Supporting protocol for CAN 0
Supporting protocol for INTERBUS 0
Supporting protocol for ASI 0
Supporting protocol for KNX 0
Supporting protocol for MODBUS 0
Supporting protocol for Data-Highway 0
Supporting protocol for DeviceNet 1
Supporting protocol for SUCONET No
Supporting protocol for LON No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFINET CBA Yes
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth No
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
IO link master No
System accessory No
Degree of protection (IP) No
Type of electric connection No
Time delay at signal exchange Yes
Fieldbus connection over separate bus coupler possible No
Rail mounting possible No
Wall mounting/direct mounting No
Front build in possible No
Rack-assembly possible No
Suitable for safety functions No
Category according to EN 954-1 Yes
SIL according to IEC 61508 IP20
Performance level acc. EN ISO 13849-1 Screw-/spring clamp connection
Appendant operation agent (Ex ia) 0 - 5 ms
Appendant operation agent (Ex ib) No
Explosion safety category for gas Yes
Explosion safety category for dust No
Width No
Height No
Depth No
Product Standards None
UL File No. None

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

EC4P-221-MTXD1
Eaton
EC4P-221-MTXX1
Eaton
EC4P-221-MRXD1
Eaton
EC4P-221-MRXX1
Eaton
EC4P-221-MTAD1
Eaton
EC4P-221-MTAX1
Eaton
EC4P-221-MRAD1
Eaton
EC4P-221-MRAX1
Eaton
EC4P-222-MTXD1
Eaton
EC4P-222-MTXX1
Eaton
EC4P-222-MRXD1
Eaton