Housing bushing socket, SmartWire-DT, socket, M20, for SWD4-SM8 plugs for round cableEnclosure bushing for flush mounting in surface mounting enclosure M22-I…, 8 pole socket for connection to SWD4-SM8-67(W), enclosure degree of protection IP67 8 prefabricated cables for connection to card M22-SWD-I...
Housing bushing socket, SmartWire-DT, socket, M20, for SWD4-SM8 plugs for round cable
Enclosure bushing for flush mounting in surface mounting enclosure M22-I…, 8 pole socket for connection to SWD4-SM8-67(W), enclosure degree of protection IP67 8 prefabricated cables for connection to card M22-SWD-I...
Basic function accessories | Housing bushing socket |
Product range | SmartWire-DT accessories |
Degree of Protection | IP20 |
Length | 0.15 m |
For use with | M22-SWD… |
Standards | IEC/EN 61131-2 EN 50178 |
Dimensions (W x H x D) | 24 x 26 x 162 mm |
Weight | 0.02 kg |
Mounting position | As required |
Note on heat dissipation | not relevant |
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP20 |
Climatic proofing | Dry heat to IEC 60068-2-2 Damp heat as per EN 60068-2-3 |
Air pressure (operation) | 795 - 1080 hPa |
Ambient temperature >Operation [ϑ] |
-25 - +55 °C |
Ambient temperature >Storage / Transport [ϑ] |
-40 - +70 °C |
Ambient temperature >Relative humidity >Condensation |
Take appropriate measures to prevent condensation |
Ambient temperature >Relative humidity >Relative humidity, non-condensing (IEC/EN 60068-2-30) |
5 - 95 % |
Connection 1 | SWD-IN: 8 cables |
Connection 2 | M20 socket, 8 pole |
Number of insertion cycles | ≥ 500 |
Rated operational current for specified heat dissipation [In] | 0 A |
Heat dissipation per pole, current-dependent [Pvid] | 0 W |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +55 °C |
Degree of Protection | IP20 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Type of electrical accessory | Plug |
Type of mechanical accessory | Other |
UL File No. | E29184 |
UL Category Control No. | NKCR |
CSA File No. | 2324643 |
CSA Class No. | 3211-07 |
North America Certification | UL listed, CSA certified |
Specially designed for North America | No |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.