Product range |
Single-phase control transformers ST... |
Basic function |
Single-phase STN control transformers |
Rated output voltage |
0.0 V |
Rated power |
0.2 kVA |
Terminal diagram / contact assignment |
|
Cu factor |
0,55 kg |
Separate windings |
● |
Note |
The following applies for the no-load loss, short-circuit loss (copper losses), short-circuit voltage and efficiency values: all details relate to a temperature of 20 °C |
No-load losses |
9 W |
Short-circuit losses |
19 W |
Rated operational current for specified heat dissipation [In] |
0 A |
Heat dissipation per pole, current-dependent [Pvid] |
0 W |
Equipment heat dissipation, current-dependent [Pvid] |
0 W |
Static heat dissipation, non-current-dependent [Pvs] |
28 W |
Heat dissipation capacity [Pdiss] |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Is the panel builder´s responsibility. |
10.8 Connections for external conductors |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Built as safety transformer |
No |
Built as isolating transformer |
No |
Built as energy saving transformer |
No |
Primary voltage 1 |
230 - 230 V |
Primary voltage 2 |
0 - 0 V |
Primary voltage 3 |
0 - 0 V |
Primary voltage 4 |
0 - 0 V |
Primary voltage 5 |
0 - 0 V |
Primary voltage 6 |
0 - 0 V |
Primary voltage 7 |
0 - 0 V |
Primary voltage 8 |
0 - 0 V |
Primary voltage 9 |
0 - 0 V |
Primary voltage 10 |
0 - 0 V |
Secondary voltage 1 |
230 - 230 V |
Secondary voltage 2 |
0 - 0 V |
Secondary voltage 3 |
0 - 0 V |
Secondary voltage 4 |
0 - 0 V |
Secondary voltage 5 |
0 - 0 V |
Secondary voltage 6 |
0 - 0 V |
Secondary voltage 7 |
0 - 0 V |
Secondary voltage 8 |
0 - 0 V |
Secondary voltage 9 |
0 - 0 V |
Secondary voltage 10 |
0 - 0 V |
Rated apparent power |
200 VA |
Type of insulation material acc. IEC 85 |
B |
Short-circuit-proof |
No |
Relative short circuit voltage |
6.8 % |
Width |
106 mm |
Height |
124 mm |
Depth |
83 mm |
Degree of protection (IP) |
IP00 |
Ring core |
No |
Suitable for mounting on PCB |
No |
Modular version |
No |
Conductor material |
Copper |