alt
alt

PKZM01-1,6
278480 PKZM01-1,6
278480

Motor-protective circuit-breaker, 660 V 690 V: 1.1 kW, Ir= 1 - 1.6 A, IP20Motor-protective circuit-breaker according to IEC/EN60947, 3 pole size PKZM01, with adjustable overload and non-delayed short-circuit release, phase failure sensitive, screw and snap fitting, cap installation dimension 45mm, rated operating voltage Ue 690V, degree of protection IP20, finger proof according to VDE 0106 T. 100, accessories: auxiliary contact, voltage release

Motor-protective circuit-breaker, 660 V 690 V: 1.1 kW, Ir= 1 - 1.6 A, IP20
Motor-protective circuit-breaker according to IEC/EN60947, 3 pole size PKZM01, with adjustable overload and non-delayed short-circuit release, phase failure sensitive, screw and snap fitting, cap installation dimension 45mm, rated operating voltage Ue 690V, degree of protection IP20, finger proof according to VDE 0106 T. 100, accessories: auxiliary contact, voltage release

Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation
Basic function Motor protection
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Contact sequence Screw terminals
AC-3
>220 V 230 V 240 V [P]
121S003
AC-3
>380 V 400 V 415 V [P]
AC-3
>440 V [P]
0.25 kW
AC-3
>500 V [P]
0.55 kW
AC-3
>660 V 690 V [P]
0.55 kW
Rated uninterrupted current [Iu] 0.75 kW
Overload releases [Ir ] 1.1 kW
short-circuit release [Irm ]
>max. [Irm ]
1.6 A
Phase-failure sensitivity
Notes 1 - 1.6 A
Standards 24.8 A
Climatic proofing IEC/EN 60947-4-1, VDE 0660 Part 102
Ambient temperature
>Storage
Overload trigger: tripping class 10 A
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height.
Ambient temperature
>Open
Ambient temperature
>Enclosed
IEC/EN 60947, VDE 0660,UL, CSA
Mounting position Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Direction of incoming supply - 40 - 80 °C
Degree of protection
>Device
-25 - +55 °C
Degree of protection
>Terminations
- 25 - 40 °C
Protection against direct contact when actuated from front (EN 50274) 1210DRW-68
Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 as required
Altitude IP20
Terminal capacity main cable
>Screw terminals
>Solid
IP00
Terminal capacity main cable
>Screw terminals
>Flexible with ferrule to DIN 46228
Finger and back-of-hand proof
Terminal capacity main cable
>Screw terminals
>Solid or stranded
25 g
Terminal capacity main cable
>Screw terminals
>Stripping length
Max. 2000 m
Specified tightening torque for terminal screws
>Main cable
1 x (1 - 6)
2 x (1 - 6) mm2
Rated impulse withstand voltage [Uimp] 1 x (1 - 6)
2 x (1 - 6) mm2
Overvoltage category/pollution degree 18 - 10 AWG
Rated operational voltage [Ue ] 10 mm
Rated uninterrupted current = rated operational current [Iu = Ie ] 1.7 Nm
Rated frequency [f]
Current heat loss (3 pole at operating temperature) 6000 V AC
Impedance per pole III/3
Lifespan, mechanical [Operations] 690 V AC
Lifespan, electrical (AC-3 at 400 V)
>Lifespan, electrical [Operations]
1.6 A
Max. operating frequency 40 - 60 Hz
Short-circuit rating
>DC
>Short-circuit rating
5.36 W
Short-circuit rating
>DC
>Notes
700 mΩ
Motor switching capacity
>AC-3 (up to 690V)
0.05 x 106
Motor switching capacity
>DC-5 (up to 250V)
0.05 x 106
Temperature compensation
>to IEC/EN 60947, VDE 0660
25 Ops/h
Temperature compensation
>Operating range
60 kA
Temperature compensation residual error for T > 40 °C up to 250 V
Setting range of overload releases 1.6 A
short-circuit release 1.6 (3 contacts in series) A
Short-circuit release tolerance
Phase-failure sensitivity - 5…40 °C
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
- 25…55 °C
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
≦ 0.25 %/K
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
0.6 - 1 x Iu
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
Basic device, fixed: 15.5 x Iu
Switching capacity
>Maximum motor rating
>Single-phase
>230 V
240 V
± 20%
Short Circuit Current Rating, group protection
>600 V High Fault
>SCCR (fuse)
IEC/EN 60947-4-1, VDE 0660 Part 102
Short Circuit Current Rating, group protection
>600 V High Fault
>max. Fuse
Short Circuit Current Rating, group protection
>600 V High Fault
>SCCR (CB)
Hinweis: Motorleistung in diesem Bereich nach Bemessungsstrom berechnen. Angegebene Werte nach NEC Table 430-150 HP
Short Circuit Current Rating, group protection
>600 V High Fault
>max. CB
Hinweis: Motorleistung in diesem Bereich nach Bemessungsstrom berechnen. Angegebene Werte nach NEC Table 430-150 HP
Rated operational current for specified heat dissipation [In] 0.75 HP
Heat dissipation per pole, current-dependent [Pvid] 0.75 HP
Equipment heat dissipation, current-dependent [Pvid] 0.1 HP
Static heat dissipation, non-current-dependent [Pvs] 50 kA
Heat dissipation capacity [Pdiss] 600 A
Operating ambient temperature min. 50 kA
Operating ambient temperature max. 600 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
1.6 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
1.79 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
5.36 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
-25 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
+55 °C
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Overload release current setting Is the panel builder´s responsibility.
Adjustment range undelayed short-circuit release Is the panel builder´s responsibility.
With thermal protection Is the panel builder´s responsibility.
Phase failure sensitive Is the panel builder´s responsibility.
Switch off technique Is the panel builder´s responsibility.
Rated operating voltage The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated permanent current Iu Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power at AC-3, 230 V Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power at AC-3, 400 V The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Type of electrical connection of main circuit
Type of control element
Device construction 1 - 1.6 A
With integrated auxiliary switch 25 - 25 A
With integrated under voltage release Yes
Number of poles Yes
Rated short-circuit breaking capacity lcu at 400 V, AC Thermomagnetic
Degree of protection (IP) 690 - 690 V
Height 1.6 A
Width 0.25 kW
Depth 0.55 kW
Product Standards Screw connection
UL File No. Push button
UL Category Control No. Built-in device fixed built-in technique
CSA File No. No
CSA Class No. No
North America Certification 3
Specially designed for North America 50 kA
Suitable for IP20
Accessories 93 mm
Characteristic curve 45 mm
Characteristic curve 90.5 mm
Characteristic curve IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.