RCD/MCB, 32A, 100mA, miniature circuit-breaker trip curve C, 3 p, residual current circuit-breaker trip characteristic: ARCBO (residual-current circuit breaker with overload protection) PKPM3, 3 pole, Tripping characteristic: C, Rated current In: 32 A, Rated switching capacity according to IEC/EN 61009: 10 kA, Rated fault current IΔN: 0.1 A, Pulse-current sensitive, Partly surge-proof 250 A, Switchgear for residential and commercial applications

RCD/MCB, 32A, 100mA, miniature circuit-breaker trip curve C, 3 p, residual current circuit-breaker trip characteristic: A
RCBO (residual-current circuit breaker with overload protection) PKPM3, 3 pole, Tripping characteristic: C, Rated current In: 32 A, Rated switching capacity according to IEC/EN 61009: 10 kA, Rated fault current IΔN: 0.1 A, Pulse-current sensitive, Partly surge-proof 250 A, Switchgear for residential and commercial applications

Basic function Combined RCD/MCB devices
Number of poles 3 pole
Tripping characteristic C
Application Switchgear for residential and commercial applications
Rated current [In] 32 A
Rated switching capacity according to IEC/EN 61009 10 kA
Rated fault current [IΔN] 0.1 A
Type Type A
Tripping non-delayed s…
Product range PKPM3
Sensitivity Pulse-current sensitive
Impulse withstand current Partly surge-proof 250 A
Types conform to IEC/EN 61009
Current test marks As per inscription
Tripping non-delayed s…
Rated frequency [f] 50 Hz
Rated fault currents [IΔn ] 30, 100 mA
Rated non-tripping current [IΔno] 0.5
Sensitivity Pulse-current sensitive
Rated impulse withstand voltage [Uimp] 4 (1.2/50μs) kV
Max. admissible back-up fuse
>Short-circuit [gG/gL]
100 A
Characteristic C
Selectivity Class 3
lifespan
>Electrical [Operations]
≧ 2000
lifespan
>Mechanical [Operations]
≧ 10000
Standard front dimension 45 mm
Device height 80 mm
Built-in width 70 (4TE) mm
Mounting Tristable slide catch enables removal from existing combination.
Degree of Protection IP20, IP40 (when fitted)
Terminals top and bottom Twin-purpose terminals
Terminal protection finger and hand touch safe, DGUV VS3, EN 50274
Terminal capacity rigid conductors 1 x (1 - 25) mm2
Tightening torque of fixing screws 2 - 2.4 N/m
Thickness of busbar material 0.8 - 2 mm
Admissible ambient temperature range -25 - +40 °C
Permissible storage and transport temperatures -35 - +60 °C
Climatic proofing in accordance with IEC/EN 61009
Rated operational current for specified heat dissipation [In] 32 A
Heat dissipation per pole, current-dependent [Pvid] 0 W
Equipment heat dissipation, current-dependent [Pvid] 12.8 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. -25 °C
Operating ambient temperature max. +40 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of poles (total) The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of protected poles 3
Rated voltage 3
Rated insulation voltage Ui 400 V
Rated impulse withstand voltage Uimp 500 V
Rated current 4 kV
Rated fault current 32 A
Leakage current type 0.1 A
Current limiting class A
Rated short-circuit breaking capacity acc. EN 61009 3
Rated short-circuit breaking capacity IEC 60947-2 10 kA
Rated short-circuit breaking capacity Icn acc. EN 61009-1 0 kA
Disconnection characteristic 10 kA
Surge current capacity
Voltage type 0.25 kA
Frequency AC
Release characteristic 50 Hz
Concurrently switching N-neutral C
With interlocking device Yes
Over voltage category No
Pollution degree 3
Ambient temperature during operating 2
Width in number of modular spacings -25 - 40 °C
Built-in depth 4
Suitable for flush-mounted installation 70 mm
Anti-nuisance tripping version No
Degree of protection (IP) No
Connectable conductor cross section solid-core IP20
Connectable conductor cross section multi-wired 1 - 25 mm²

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

PKNM-32/1N/C/003-F-MW
Eaton
HNB-C20/1N/003-A-HX
Eaton
HNB-C6/1N/003-A-HX
Eaton
HNB-C6/1N/003-HX
Eaton
HNB-B16/1N/003-A
Eaton