Basic function accessories |
Function elements |
Function |
for combination with RMQ-Titan operating elements M22-... |
Contacts |
2 changeover contact |
Fixing |
Front fixing |
Contact sequence |
|
Contact travel diagram stroke in connection with front element |
|
Configuration |
|
Connection to SmartWire-DT |
yes |
Standards |
IEC/EN 61131-2 EN 50178 |
Approvals >shipping classification |
DNV GL BV LRS |
Dimensions (W x H x D) |
17 x 42 x 39 mm |
Weight |
14 g |
Mounting position |
As required |
Protection type (IEC/EN 60529, EN50178, VBG 4) |
IP20 |
Vibrations (IEC/EN 61131-2:2008) >Constant amplitude 3,5 mm |
5 - 8.4 Hz |
Vibrations (IEC/EN 61131-2:2008) >Constant acceleration 1 g |
8.4 - 150 Hz |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms |
9 Impacts |
Drop to IEC/EN 60068-2-31 [Drop height] |
50 mm |
Free fall, packaged (IEC/EN 60068-2-32) |
0.3 m |
Overvoltage category |
Not applicable |
Pollution degree |
2 |
Electrostatic discharge (IEC/EN 61131-2:2008) >Air discharge (Level 3) |
8 kV |
Electrostatic discharge (IEC/EN 61131-2:2008) >Contact discharge (Level 2) |
4 kV |
Electromagnetic fields (IEC/EN 61131-2:2008) >80 - 1000 MHz |
10 V/m |
Electromagnetic fields (IEC/EN 61131-2:2008) >1.4 - 2 GHz |
3 V/m |
Electromagnetic fields (IEC/EN 61131-2:2008) >2 - 2.7 GHz |
1 V/m |
Radio interference suppression (SmartWire-DT) |
EN 55011 Class A |
Burst (IEC/EN 61131-2:2008, Level 3) >Supply cable |
2 kV |
Burst (IEC/EN 61131-2:2008, Level 3) >SmartWire-DT cable |
1 kV |
Radiated RFI (IEC/EN 61131-2:2008, Level 3) |
10 V |
Ambient temperature >Operating ambient temperature (IEC 60068-2) |
-30 - +70 °C |
Ambient temperature >Storage |
- 40 - + 80 °C |
Relative humidity >Condensation |
Take appropriate measures to prevent condensation |
Relative humidity >Relative humidity, non-condensing (IEC/EN 60068-2-30) |
5 - 95 % |
Station type |
SmartWire-DT slave |
Address allocation |
automatic |
Status indication |
Green LED |
Connections |
Plug, 8-pole |
Plug connectors |
SWD4-8SF2-5 |
Baud rate setting |
automatic |
Switching state display |
No LED |
Diagnostics |
Yes |
Fixing |
Front fixing |
Rated operational current for specified heat dissipation [In] |
0 A |
Heat dissipation per pole, current-dependent [Pvid] |
0 W |
Equipment heat dissipation, current-dependent [Pvid] |
0 W |
Static heat dissipation, non-current-dependent [Pvs] |
0.3 W |
Heat dissipation capacity [Pdiss] |
0 W |
Operating ambient temperature min. |
-30 °C |
Operating ambient temperature max. |
+70 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Is the panel builder´s responsibility. |
10.8 Connections for external conductors |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of contacts as change-over contact |
0 |
Number of contacts as normally open contact |
2 |
Number of contacts as normally closed contact |
2 |
Number of fault-signal switches |
0 |
Rated operation current Ie at AC-15, 230 V |
0 A |
Type of electric connection |
Flat plug-in connection |
Model |
Top mounting |
Mounting method |
Front fastening |
Lamp holder |
None |
UL File No. |
E29184 |
UL Category Control No. |
NKCR |
CSA File No. |
2324643 |
CSA Class No. |
3211-07 |
North America Certification |
UL listed, CSA certified |
Specially designed for North America |
No |