SWD module for 3-way hydraulic valve IP65SmartWire-DT devices in protection category IP65 for connection of a hydraulic three-way switch valve. Primary valve connection as per DIN EN 175301-803, connection to second valve coil with M12 connector (A-coded, 4-pin). Automatic address setting, digital outputs 24 V DC 1.6/1.3 A (60/70 °C) and short-circuit protection
SWD module for 3-way hydraulic valve IP65
SmartWire-DT devices in protection category IP65 for connection of a hydraulic three-way switch valve. Primary valve connection as per DIN EN 175301-803, connection to second valve coil with M12 connector (A-coded, 4-pin). Automatic address setting, digital outputs 24 V DC 1.6/1.3 A (60/70 °C) and short-circuit protection
Product range | SmartWire-DT slave |
Basic function | Digital modules |
Function | For connecting digital 3-way switching valves |
Short Description | with supply |
Connection to SmartWire-DT | yes |
Standards | IEC/EN 61131-2 EN 50178_x |
Approvals >Approvals |
UL |
Dimensions (W x H x D) | 44.7 x 77.4 x 51.9 mm |
Weight | 0.09 kg |
Mounting | Can be screwed onto valve connector in conformity with DIN EN 175301-803 |
Mounting position | As required |
Power supply >Power loss [P] |
2.5 W |
Air pressure (operation) | 795 - 1080 hPa |
Ambient temperature >Operation [ϑ] |
-25 - +70 (observe derating) °C |
Ambient temperature >Storage / Transport [ϑ] |
-40 - +85 °C |
Relative humidity >Condensation |
permissible |
Relative humidity >Relative humidity, non-condensing (IEC/EN 60068-2-30) |
5 - 95 % |
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP65 |
Vibrations (IEC/EN 61131-2:2008) >Constant amplitude 3,5 mm |
5 - 8.4 Hz |
Vibrations (IEC/EN 61131-2:2008) >Constant acceleration 1 g |
8.4 - 150 Hz |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 30 g/11 ms | 9 Impacts |
Drop to IEC/EN 60068-2-31 [Drop height] | 50 mm |
Free fall, packaged (IEC/EN 60068-2-32) | 0.3 m |
Overvoltage category | II |
Pollution degree | 3 |
Electrostatic discharge (IEC/EN 61131-2:2008) >Air discharge (Level 3) |
8 kV |
Electrostatic discharge (IEC/EN 61131-2:2008) >Contact discharge (Level 2) |
4 kV |
Electromagnetic fields (IEC/EN 61131-2:2008) >80 - 1000 MHz |
10 V/m |
Electromagnetic fields (IEC/EN 61131-2:2008) >1.4 - 2 GHz |
3 V/m |
Electromagnetic fields (IEC/EN 61131-2:2008) >2 - 2.7 GHz |
1 V/m |
Radio interference suppression (SmartWire-DT) | EN 55011 Class A |
Burst (IEC/EN 61131-2:2008, Level 3) >Supply cable |
2 kV |
Burst (IEC/EN 61131-2:2008, Level 3) >SmartWire-DT cables |
1 kV |
Surge (IEC/EN 61131-2:2008, Level 1) >Surge power cables |
1 kV |
Radiated RFI (IEC/EN 61131-2:2008, Level 3) | 10 V |
Station type | SmartWire-DT slave |
Setting the baud rate | automatic |
Baud rate (data transfer speed) | maximum125/250/500/1000/2000 kbps |
Status SmartWire-DT | Green LED |
SWD-IN | M12 plug (A-keyed), 5 pole |
SWD-OUT | M12 plug (A-keyed), 5 pole |
Current consumption (24V, without sensor and without I/O supply) >Current consumption (24 V SWD supply) |
50 mA |
Sensor supply >Overload and short-circuit proof |
yes, with diagnostics |
Terminal for I/O sensor >Connection type |
DIN-A valve connector, M12 socket (A-keyed), 4 pole |
Quantity | 2 |
Output current | 1.6 (at 60°C), 1.3 (at 70°C) A |
Overload proof | yes, with diagnostics |
Maximum switching frequency | 1 Hz |
Status display outputs | yellow LED |
Rated operational voltage [UAux] | 24 V DC (-15/+20%) V |
Permissible range | 20.4 - 28.8 V DC |
Siemens MPI, (optional) | yes |
Short-circuit rating | Not relevant |
Potential isolation | Galvanically isolated from the SmartWire-DT network |
Outputs to SmartWire-DT | Yes |
Rated operational current for specified heat dissipation [In] | 1.6 A |
Equipment heat dissipation, current-dependent [Pvid] | 1 W |
Static heat dissipation, non-current-dependent [Pvs] | 1.5 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +70 °C |
Degree of Protection | IP65 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
UL File No. | E205091 |
North America Certification | UL listed |
Specially designed for North America | No |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.