SWD T-Connector counter module IP69K, one counter input with power supply, M12 I/O socketSmartWire-DT module with IP67 degree of protection for connecting one digital meter; 24 VDC, 70 mA short-circuit proof power supply for counter; automatic address setting; 24 VDC simple counter, incremental encoder (A, B, R) with X1, X2, X4 encoding; Up/Down Counter up to 30 kHz; counter connection with M12 socket
SWD T-Connector counter module IP69K, one counter input with power supply, M12 I/O socket
SmartWire-DT module with IP67 degree of protection for connecting one digital meter; 24 VDC, 70 mA short-circuit proof power supply for counter; automatic address setting; 24 VDC simple counter, incremental encoder (A, B, R) with X1, X2, X4 encoding; Up/Down Counter up to 30 kHz; counter connection with M12 socket
Product range | SmartWire-DT slave |
Basic function | Counter module |
Function | For connecting a counter |
Short Description | Counter/incremental encoder 24 V DC, max. 30 kHz |
meter | 1 |
Connection to SmartWire-DT | yes |
Standards | IEC/EN 61131-2 |
Approvals >Approvals |
UL CSA |
Dimensions (W x H x D) | 85.6 x 56.9 x 20.1 mm |
Weight | 0.07 kg |
Mounting | DIN-rail, screw fixing (M4), mounting section (Clip M20) |
Mounting position | As required |
Power supply >Power loss [P] |
1.4 W |
Climatic proofing | Dry heat to IEC 60068-2-2 Damp heat as per EN 60068-2-3 |
Air pressure (operation) | 795 - 1080 hPa |
Ambient temperature >Operation [ϑ] |
-25 - +70 °C |
Ambient temperature >Storage / Transport [ϑ] |
-40 - +70 °C |
Relative humidity >Condensation |
permissible |
Relative humidity >Relative humidity, non-condensing (IEC/EN 60068-2-30) |
5 - 95 % |
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP69K |
Vibrations (IEC/EN 61131-2:2008) >Constant amplitude 3,5 mm |
5 - 8.4 Hz |
Vibrations (IEC/EN 61131-2:2008) >Constant acceleration 1 g |
8.4 - 150 Hz |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 30 g/11 ms | 9 Impacts |
Drop to IEC/EN 60068-2-31 [Drop height] | 50 mm |
Free fall, packaged (IEC/EN 60068-2-32) | 0.3 m |
Overvoltage category | II |
Pollution degree | 3 |
Electrostatic discharge (IEC/EN 61131-2:2008) >Air discharge (Level 3) |
8 kV |
Electrostatic discharge (IEC/EN 61131-2:2008) >Contact discharge (Level 2) |
4 kV |
Electromagnetic fields (IEC/EN 61131-2:2008) >80 - 1000 MHz |
10 V/m |
Electromagnetic fields (IEC/EN 61131-2:2008) >1.4 - 2 GHz |
3 V/m |
Electromagnetic fields (IEC/EN 61131-2:2008) >2 - 2.7 GHz |
1 V/m |
Radio interference suppression (SmartWire-DT) | EN 55011 Class A |
Burst (IEC/EN 61131-2:2008, Level 3) >Supply cable |
2 kV |
Burst (IEC/EN 61131-2:2008, Level 3) >Signal lines |
1 kV |
Burst (IEC/EN 61131-2:2008, Level 3) >SmartWire-DT cables |
1 kV |
Surge (IEC/EN 61131-2:2008, Level 1) >Surge power cables |
0.5 kV |
Surge (IEC/EN 61131-2:2008, Level 1) >Surge I/O cables |
1 kV |
Radiated RFI (IEC/EN 61131-2:2008, Level 3) | 10 V |
Station type | SmartWire-DT slave |
Setting the baud rate | automatic |
Baud rate (data transfer speed) | maximum2000 kbps |
Status SmartWire-DT | Green LED |
SWD-IN | M12 plug (A-keyed), 5 pole |
SWD-OUT | M12 socket (A-keyed), 5 pole |
Current consumption (24V, without sensor and without I/O supply) >Current consumption (24 V SWD supply) |
57 mA |
Sensor supply >Max. current consumption per M12 I/O plug |
70 mA |
Sensor supply >Overload and short-circuit proof |
yes, with diagnostics |
Terminal for I/O sensor >Connection type |
5-pin M12 socket (A-keyed) |
Quantity | 1 |
Input rated voltage | 24 V DC |
Counter input frequency | Max.30 kHz |
Counter value | 32 Bit |
Incremental encoder function >Encoder inputs |
A,B,reference |
Incremental encoder function >Encoding |
X1, X2, X4 |
Incremental encoder function >Frequency measurement |
0-65535 Hz |
Simple counter function >Counter inputs |
Counter pulse, direction, reference mark |
Simple counter function >Encoding |
1.2-way |
Simple counter function >Frequency measurement |
0-65535 Hz |
Counter status indicator | yellow LED |
Inputs for SmartWire-DT | No |
Rated operational current for specified heat dissipation [In] | 0 A |
Heat dissipation per pole, current-dependent [Pvid] | 0 W |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 1.4 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +70 °C |
Degree of Protection | IP69K |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of functions | 3 |
Redundancy | No |
Suitable for counting | Yes |
Suitable for weighting | No |
Suitable for temperature control | No |
Suitable for welding control | No |
Suitable for pressure control | No |
Suitable for NC | No |
Function electronic positioning available | Yes |
Suitable for CNC | No |
Suitable for SSI | No |
Suitable for incremental data detection | Yes |
Suitable for detection absolute value | No |
Flux controller possible | Yes |
Suitable for flux measurement | No |
Suitable for path controller | Yes |
Suitable for cam controller | No |
Suitable for flying saw | No |
Suitable for multi-axis control | No |
Single-axis controller possible | Yes |
Suitable for multi-axis positioning | No |
Single-axis positioning possible | Yes |
Suitable for safety functions | No |
Category according to EN 954-1 | |
SIL according to IEC 61508 | None |
Performance level acc. EN ISO 13849-1 | None |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Width | 85.6 mm |
Height | 56.9 mm |
Depth | 20.1 mm |
UL File No. | E170645 |
North America Certification | UL listed, CSA certified |
Specially designed for North America | No |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.