Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling pathsSafety relay dual-channel, for implementing the basic functions emergency switching off, emergency stop, and protective door, supply voltage 24VDC or 24VAC 50/60Hz, 3 Enable current paths (IEC/EN 60204 Stop category 0), 1 signal current path, busbar tag shroud to EN 50274 with vertical actuation from the front finger- and back-of-hand proof, suitable for cat. 4 according to EN 954-1 / PL e according to EN ISO 13849-1 / SILCL 3 according to IEC 62061 / SIL 3 according to IEC 61508, degree of protection IP20, installation location IP54 minimum, TÜV tested, rated impulse voltage 4 kV / basic isolation (safe isolation, reinforced insulation and 6 kV between input current circuit and enable contacts.)
Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths
Safety relay dual-channel, for implementing the basic functions emergency switching off, emergency stop, and protective door, supply voltage 24VDC or 24VAC 50/60Hz, 3 Enable current paths (IEC/EN 60204 Stop category 0), 1 signal current path, busbar tag shroud to EN 50274 with vertical actuation from the front finger- and back-of-hand proof, suitable for cat. 4 according to EN 954-1 / PL e according to EN ISO 13849-1 / SILCL 3 according to IEC 62061 / SIL 3 according to IEC 61508, degree of protection IP20, installation location IP54 minimum, TÜV tested, rated impulse voltage 4 kV / basic isolation (safe isolation, reinforced insulation and 6 kV between input current circuit and enable contacts.)
Product range | Electronic safety relays |
Basic function | Emergency stop; emergency switching off Protective door Feedback circuit |
Mounting width | |
Operation | 22.5 mm |
Supply voltage [Us] | Automatic reset |
Approval | single-channel dual-channel |
Safety related characteristics | 24 V DC 24 V AC, 50/60 Hz |
Enable current paths to IEC/EN 60204-1 Stop category 0 | |
Signal current paths | Cat. 4 PL e according to EN ISO 13849-1 SILCL 3 according to IEC 62061 SIL 3 according to IEC 61508 |
Intended use | |
Policies List | 3 |
Standards | 1 |
Dimensions (W x H x D) | |
Mounting width | Safety relay for monitoring emergency stop and protective door switch. Module used to safely interrupt electrical circuits. |
Weight | EMV 2004/108/EG, Maschinen 2006/42/EG |
Mounting position | EN ISO 13849-1:2008, EN 62061:2005+AC:2010, EN 61508, Parts 1-7:2001, EN 50178:1997, EN 60204-1:2006+A1:2009 |
Mounting | 22.5 x 99 x 114.5 mm |
Connection type | 22.5 mm |
Lifespan, mechanical [Operations] | 0,23 kg |
Terminal capacity >Solid |
As required |
Terminal capacity >Flexible with ferrule |
Top-hat rail IEC/EN 60715, 35 mm |
Terminal capacity >Solid or stranded |
M3 screw terminals |
Terminal screw >Pozidriv screwdriver |
10 x 106 |
Terminal screw >Standard screwdriver |
1x (0.2 – 2.5) 2x (0.2 – 1) mm2 |
Terminal screw >Max. tightening torque |
1x (0.25 – 2.5) 2x (0.25 – 1) mm2 |
Stripping length | 24 - 12 AWG |
Material | 2 Size |
Duty factor | 0.6 x 3.5 mm |
Operating conditions >Climatic environmental conditions >Climatic proofing |
0.6 Nm |
Operating conditions >Ambient temperature >Operation [ϑ] |
7 mm |
Operating conditions >Ambient temperature >Storage [ϑ] |
Housing: polyamide PA not reinforced Contacts: Material: silver tin oxide, gold plated (AgSnO2, 0.2 µm Au) |
Operating conditions >Ambient temperature >Condensation |
100 % DF |
Operating conditions >Atmospheric conditions >relative humidity |
Cold to EN 60068-2-1 Dry heat to IEC 60068-2-2 Damp heat as per EN 60068-2-3 |
Operating conditions >Atmospheric conditions >Air pressure (operation) |
-20 - +55 °C |
Operating conditions >Atmospheric conditions >Altitude [Above sea level] |
-40 - +70 °C |
Power loss [P] | Non-condensing |
Degree of protection to VDE 0470-1 >Enclosures |
Max. 75 % |
Degree of protection to VDE 0470-1 >Terminals |
795 - 1080 hPa |
Degree of protection to VDE 0470-1 >Degree of Protection |
2000 m |
Degree of protection to VDE 0470-1 >B10d [switching cycles] |
5.16 W |
Protection against direct contact when actuated from front (EN 50274) | |
Vibrations (IEC/EN 60068-2-6) | IP20 |
Clearance in air and creepage distances | IP20 |
Rated impulse withstand voltage [Uimp] | Installation location: ≥ IP54 |
Insulation | 300000 |
Overvoltage category/pollution degree | Finger and back-of-hand proof |
Stop category [according to EN60204-1] | 10 - 150 Hz Amplitude: 0.15 mm Acceleration: 2 g |
Technical safety parameters: >Values according to EN ISO 13849-1 >Performance level [according to EN ISO 13849-1] |
EN 50178, UL 508, CSA C22.2, No. 14-95 |
Technical safety parameters: >Values according to EN ISO 13849-1 >Category [according to EN ISO 13849-1] |
4000 V AC |
Safety integrity level claim limit [in accordance with 62061] | Basic isolation Safe isolation, reinforced isolation, and 6 kV between input circuit and enable current paths. |
Safety integrity level [In accordance with IEC 61508] | III/2 |
Probability of failure per hour [PFHd] | 5,05 |
Prooftest High Demand | PL e |
Demand level | Kat. 4 |
Prooftest Low Demand | SILCL 3 |
Lifetime | SIL 3 |
Rated operational voltage [Ue] | 5.05 x 10-10 |
Rated operational voltage [Ue] | 240 Months |
Permissible range | < 12 Months |
Rated insulation voltage [Ui] | 66 Months |
Quadratic summation current | 240 Months |
Notes | 230 V AC |
Inrush current | 24 V AC, 24 V DC V |
Minimum switching capacity | 0.85 - 1.1 x Ue |
Power supply circuit >AC operated 50/60 Hz |
250 V AC |
Power supply circuit >DC operated |
72 A2 (ITH2 = I12 + I22 + I32) A2 |
Fuse for control circuit supply >24 V |
Observe derating curve → Engineering |
Rated current | min - max0.025 - 6 A |
Current consumption | 0.4 W |
Voltage at input, starting and feedback circuit | |
Max. resistive load of the cable [R] | 3.4 W |
Short-circuit current | 1.6 W |
Pick-up time (K1, K2) for UN automatic mode, typical [tA] | short-circuit proof |
Pick-up time | |
Reset time (K1, K2) for UN , normally [tR] | S12, S22:30, S34:45 mA |
Recovery time [tW ] | AC: 140 DC: 65 mA |
Simultaneity for inputs 1/2 [tsync] | Approx. 24 V DC |
Maximum permissible total cable resistance (input and starting circuits for UN) [RL] | ≦ 50 Ω |
Maximum switching frequency | 2.3 A |
Status indication | 100 ms |
Contact type >Non-delayed enable current paths |
at Ue in automatic mode: normally 100 ms |
Contact type >Delayed signal current path |
45 (single-channel) 10 (dual-channel) ms |
Switching voltage | Approx. 1000 ms |
Limiting continuous current | ∞ ms |
Short-circuit protection for output circuits, external | approx. 50 Ω |
Output fuse >NEOZED (N/O) |
0.5 Hz |
Output fuse >NEOZED (N/C) |
Green LED |
Maximum breaking power >Resistive load (τ = 0 ms) >24 V DC |
|
Maximum breaking power >Resistive load (τ = 0 ms) >48 V DC |
3 |
Maximum breaking power >Resistive load (τ = 0 ms) >110 V DC |
1 |
Maximum breaking power >Resistive load (τ = 0 ms) >220 V DC |
min – max15 - 250 V AC 15 - 250 V DC |
Maximum breaking power >Resistive load (τ = 0 ms) >250 V AC |
perN/O: 6 N/C: 6 A |
Maximum breaking power >Inductive load (τ = 40 ms) >24 V DC |
Fuse 6 A gL/gG |
Maximum breaking power >Inductive load (τ = 40 ms) >48 V DC |
10 gL/gG |
Maximum breaking power >Inductive load (τ = 40 ms) >110 V DC |
6 gL/gG |
Maximum breaking power >Inductive load (τ = 40 ms) >220 V DC |
144 W |
Switching capacity | 288 W |
Switching capacity >AC-15 >230 V |
77 W |
Switching capacity >DC-13 >24 V |
88 W |
Further information (flip catalog) | 1500 VA |
Emitted interference | 48 W |
Interference immunity | 40 W |
Rated operational current for specified heat dissipation [In] | 35 W |
Heat dissipation per pole, current-dependent [Pvid] | 33 W |
Equipment heat dissipation, current-dependent [Pvid] | In accordance with IEC 60947-5-1 |
Static heat dissipation, non-current-dependent [Pvs] | 4 A bei 360 S/h 3 A bei 3600S/h A |
Heat dissipation capacity [Pdiss] | 4 A bei 360 S/h 2.5 A bei 3600S/h A |
Operating ambient temperature min. | description |
Operating ambient temperature max. | |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
In accordance with EN 61000-6-4 |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
In accordance with EN 61000-6-2 EN 662061_x |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
|
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 A |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
0 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
5.16 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
0 W |
10.3 Degree of protection of ASSEMBLIES | -20 °C |
10.4 Clearances and creepage distances | +55 °C |
10.5 Protection against electric shock | |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise | Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating | Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility | Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function | Meets the product standard´s requirements. |
Model | Does not apply, since the entire switchgear needs to be evaluated. |
Suitable for monitoring of position switches | Does not apply, since the entire switchgear needs to be evaluated. |
Suitable for monitoring of emergency-stop circuits | Is the panel builder´s responsibility. |
Suitable for monitoring of valves | Is the panel builder´s responsibility. |
Suitable for monitoring of optoelectronic protection equipment | Is the panel builder´s responsibility. |
Suitable for monitoring of tactile sensors | Is the panel builder´s responsibility. |
Suitable for monitoring of magnetic switches | Is the panel builder´s responsibility. |
Suitable for monitoring of proximity switches | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Type of electric connection | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rail mounting possible | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated control supply voltage Us at AC 50HZ | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated control supply voltage Us at AC 60HZ | |
Rated control supply voltage Us at DC | |
Voltage type for actuating | Basic device |
With detachable clamps | Yes |
Evaluation inputs | Yes |
With start input | No |
With muting function | No |
With feedback circuit | No |
Release-delay | No |
Number of outputs, safety related, undelayed, with contact | No |
Number of outputs, safety related, delayed, with contact | Screw connection |
Number of outputs, safety related, undelayed, semiconductors | Yes |
Number of outputs, safety related, delayed, semiconductors | 0 - 26.4 V |
Number of outputs, signalling function, undelayed, with contact | 0 - 0 V |
Number of outputs, signalling function, delayed, with contact | 0 - 0 V |
Number of outputs, signalling function, undelayed, semiconductors | AC/DC |
Number of outputs, signalling function, delayed, semiconductors | Yes |
Category according to EN 954-1 | One- and two-channel |
Type of safety acc. IEC 61496-1 | Yes |
Stop category acc. IEC 60204 | No |
Performance level acc. EN ISO 13849-1 | Yes |
SIL according to IEC 61508 | 0 - 0 s |
With approval for TÜV | 3 |
With approval for BG BIA | 0 |
With approval according to UL | 0 |
Width | 0 |
Height | 1 |
Depth | 0 |
Product Standards | 0 |
UL File No. | 0 |
UL Category Control No. | 4 |
CSA File No. | None |
CSA Class No. | 0 |
North America Certification | Level e |
Degree of Protection | 3 |
Characteristic curve | Yes |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.