alt
alt

ESR5-BWS-31-24VAC-DC
180413 ESR5-BWS-31-24VAC-DC
180413

Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling pathsSafety relay for implementing emergency stop / protective door and light curtain monitoring basic functions up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single-channel or dual-channel operation, 3 enable current paths, input rated voltage 24 V AC/DC

Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths
Safety relay for implementing emergency stop / protective door and light curtain monitoring basic functions up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single-channel or dual-channel operation, 3 enable current paths, input rated voltage 24 V AC/DC

Product range Electronic safety relays
Basic function Emergency stop; emergency switching off
Protective door
Light curtain
Mounting width
Operation 22.5 mm
Supply voltage [Us] Automatic or manually controlled start, feedback current path, external contactor monitoring
Approval single-channel
dual-channel
Safety related characteristics 24 V DC
24 V AC, 50/60 Hz
Enable current paths to IEC/EN 60204-1 Stop category 0 0000SPC-127
Signal current paths Cat. 4
PL e according to EN ISO 13849-1
SILCL 3 according to IEC 62061
EN 574 Typ III C
SIL 3 according to IEC 61508
Intended use
Policies List 3
Standards 1
Dimensions (W x H x D)
Mounting width Safety relay for monitoring emergency stop and protective door switch and light curtains.
Module used to safely interrupt electrical circuits.
Weight EMV 2004/108/EG, Maschinen 2006/42/EG
Mounting position EN ISO 13849-1:2008,
EN 62061:2006,
EN 60204:1997,
EN 61000-6-2:2005,
EN 61000-6-4:2007
Mounting 22.5 x 99 x 114.5 mm
Connection type 22.5 mm
Terminal capacity
>Solid
0,21 kg
Terminal capacity
>Flexible with ferrule
As required
Terminal capacity
>Solid or stranded
Top-hat rail IEC/EN 60715, 35 mm
Terminal screw
>Pozidriv screwdriver
M3 screw terminals
Terminal screw
>Standard screwdriver
1x (0.2 – 2.5)
2x (0.2 – 1) mm2
Terminal screw
>Max. tightening torque
1x (0.25 – 2.5)
2x (0.25 – 1) mm2
Stripping length 24 - 12 AWG
Operating conditions
>Ambient temperature
>Operation [ϑ]
2 Size
Operating conditions
>Ambient temperature
>Storage [ϑ]
0.6 x 3.5 mm
Operating conditions
>Ambient temperature
>Condensation
0.6 Nm
Operating conditions
>Atmospheric conditions
>relative humidity
7 mm
Operating conditions
>Atmospheric conditions
>Air pressure (operation)
-20 - +55 °C
Operating conditions
>Atmospheric conditions
>Altitude [Above sea level]
-40 - +70 °C
Power loss [P] Non-condensing
Degree of protection to VDE 0470-1
>Enclosures
Max. 75 %
Degree of protection to VDE 0470-1
>Terminals
795 - 1080 hPa
Degree of protection to VDE 0470-1
>Degree of Protection
2000 m
Degree of protection to VDE 0470-1
>B10d [switching cycles]
5.16 W
Protection against direct contact when actuated from front (EN 50274)
Vibrations (IEC/EN 60068-2-6) IP20
Clearance in air and creepage distances IP20
Rated impulse withstand voltage [Uimp] Installation location: ≥ IP54
Insulation 300000
Overvoltage category/pollution degree Finger and back-of-hand proof
Stop category [according to EN60204-1] 10 - 150 Hz

Amplitude: 0.15 mm

Acceleration: 2 g
Technical safety parameters:
>Values according to EN ISO 13849-1
>Performance level [according to EN ISO 13849-1]
EN 50178
Technical safety parameters:
>Values according to EN ISO 13849-1
>Category [according to EN ISO 13849-1]
4000 V AC
Safety integrity level claim limit [in accordance with 62061] Basic isolation
Safe isolation, reinforced isolation, and 6 kV between input circuit and enable current paths.
Safety integrity level [In accordance with IEC 61508] III/2
Probability of failure per hour [PFHd] 0
Prooftest High Demand PL e
Prooftest Low Demand Kat. 4
Rated operational voltage [Ue] SILCL 3
Permissible range SIL 3
Quadratic summation current 5.56 x 10-10
Notes 240 Months
Inrush current 75 Months
Current consumption 24 V AC, 24 V DC V
Voltage at input, starting and feedback circuit 0.85 - 1.1 x Ue
Pick-up time (K1, K2) for UN automatic mode, typical [tA] 72 A2 (ITH2 = I12 + I22 + I32) A2
Pick-up time (K1, K2) for UN manual operation, typical [tA] Observe derating curve
→ Engineering
Pick-up time min - max0.4 A
Reset time (K1, K2) for UN , normally [tR]
Recovery time [tW ] AC: 150
DC: 70 mA
Simultaneity for inputs 1/2 [tsync] Approx. 24 V DC
Status indication 100 ms
Contact type
>Non-delayed enable current paths
25 ms
Contact type
>Non-delayed signal current path
at Ue in automatic mode: normally 100
at Ue in manual mode: normally 25 ms
Switching voltage 10 ms
Limiting continuous current Approx. 1000 ms
Short-circuit protection for output circuits, external ∞ ms
Output fuse
>NEOZED (N/O)
Green LED
Maximum breaking power
>Resistive load (τ = 0 ms)
>24 V DC
Maximum breaking power
>Resistive load (τ = 0 ms)
>48 V DC
3
Maximum breaking power
>Resistive load (τ = 0 ms)
>110 V DC
1
Maximum breaking power
>Resistive load (τ = 0 ms)
>220 V DC
min – max15 - 250 V AC
15 - 250 V DC
Maximum breaking power
>Resistive load (τ = 0 ms)
>250 V AC
perN/O: 6
N/C: 6 A
Maximum breaking power
>Inductive load (τ = 40 ms)
>24 V DC
Fuse 10 A gL/gG NEOZED
Maximum breaking power
>Inductive load (τ = 40 ms)
>48 V DC
10 gL/gG
Maximum breaking power
>Inductive load (τ = 40 ms)
>110 V DC
144 W
Maximum breaking power
>Inductive load (τ = 40 ms)
>220 V DC
288 W
Switching capacity 77 W
Switching capacity
>AC-15
>230 V
88 W
Switching capacity
>DC-13
>24 V
1500 VA
Emitted interference 48 W
Interference immunity 40 W
Rated operational current for specified heat dissipation [In] 35 W
Heat dissipation per pole, current-dependent [Pvid] 33 W
Equipment heat dissipation, current-dependent [Pvid] In accordance with IEC 60947-5-1
Static heat dissipation, non-current-dependent [Pvs] 5 A bei 360 S/h
3 A bei 3600S/h A
Heat dissipation capacity [Pdiss] 6 A bei 360 S/h
3 A bei 3600S/h A
Operating ambient temperature min.
Operating ambient temperature max. In accordance with EN 61000-6-4
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
according to EN 61000-6-2
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
5.16 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
-20 °C
10.3 Degree of protection of ASSEMBLIES +55 °C
10.4 Clearances and creepage distances
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Model Does not apply, since the entire switchgear needs to be evaluated.
Suitable for monitoring of position switches Is the panel builder´s responsibility.
Suitable for monitoring of emergency-stop circuits Is the panel builder´s responsibility.
Suitable for monitoring of valves Is the panel builder´s responsibility.
Suitable for monitoring of optoelectronic protection equipment Is the panel builder´s responsibility.
Suitable for monitoring of tactile sensors Is the panel builder´s responsibility.
Suitable for monitoring of magnetic switches The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Suitable for monitoring of proximity switches Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Type of electric connection Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rail mounting possible The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated control supply voltage Us at AC 50HZ
Rated control supply voltage Us at AC 60HZ
Rated control supply voltage Us at DC Basic device
Voltage type for actuating Yes
With detachable clamps Yes
Evaluation inputs No
With start input No
With muting function No
With feedback circuit No
Release-delay No
Number of outputs, safety related, undelayed, with contact Screw connection
Number of outputs, safety related, delayed, with contact Yes
Number of outputs, safety related, undelayed, semiconductors 20.4 - 26.4 V
Number of outputs, safety related, delayed, semiconductors 0 - 0 V
Number of outputs, signalling function, undelayed, with contact 24 - 24 V
Number of outputs, signalling function, delayed, with contact AC/DC
Number of outputs, signalling function, undelayed, semiconductors Yes
Number of outputs, signalling function, delayed, semiconductors One- and two-channel
Category according to EN 954-1 No
Type of safety acc. IEC 61496-1 No
Stop category acc. IEC 60204 Yes
Performance level acc. EN ISO 13849-1 0 - 0 s
SIL according to IEC 61508 0
With approval for TÜV 0
With approval for BG BIA 0
With approval according to UL 0
Width 1
Height 0
Depth 0
Product Standards 0
UL File No. 4
UL Category Control No. None
CSA File No. 0
CSA Class No. Level e
North America Certification 3
Degree of Protection Yes
Characteristic curve No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

PKE32/XTUCP-36
Eaton
EMT6-DB(230V)
Eaton
PKE65/XTUWCP-36
Eaton
PKE65/XTUCP-65
Eaton
MSC-D-16-M15(230V50HZ)
Eaton
MSC-D-16-M15(24VDC)
Eaton
MSC-D-10-M17(230V50HZ)
Eaton
MSC-D-12-M17(230V50HZ)
Eaton